Long Term Vital Parameter Monitoring (LAVIMO) (LAVIMO)
26. November 2013 aktualisiert von: RWTH Aachen University
Long Term Vital Parameter Monitoring Pilot Study to Evaluate Measurement Data Via In-ear Sensor in Comparison to Standard Polysomnography in Sleep Laboratory
The purpose of this study is to evaluate the feasibility of non-intrusive 24 hours non-invasive measurements with minimized LAVIMO sensor system.
The LAVIMO-system is a photoplethysmographic device for reflective mode measurements of the optical damping upper skin layers inside of the ear canal at two different wave lengths.
It consists of the in-ear sensor, the electronics and a PC.
Vital signs parameter like heart rate, heart rate variability, breathing and arterial blood oxygenation are monitored in patients with sleep apnoea and compared to measurements of standard polysomnography of these patients during one night in the sleep laboratory.
Studienübersicht
Status
Abgeschlossen
Bedingungen
Intervention / Behandlung
Detaillierte Beschreibung
In 20 patients who routinely have to undergo a polysomnographic night in sleep laboratory LAVIMO measurements like heart rate, heart rate variability, breathing and arterial blood oxygenation are performed parallel to standard polysomnography measurements and subsequently compared to the data of the standard polysomnography.
The LAVIMO sensor system consists of the in- ear sensor, the electronics and a PC; the individually formed sensor is embedded into an ear mould for proper fit inside the ear canal.
Inside two LEDs emit light into the adjacent skin at 760 and 905 nm wavelengths.
The intensity of the backscattered light is detected by a photo detector.
In the electronics, the control signals for the LEDs are provided, as well as the photo detector signal is further processed and A-D converted.
The electronics also provide a wireless connection to the PC via bluetooth.
Data recording, post processing and displaying are tasks of the PC.
The feasibility of non- intrusive 24 hours and non-invasive measurements like heart rate, heart rate variability, breathing and oxygen saturation is proved via this minimized sensor and electronics placed at a suitable place at the body guaranteeing high wearing comfort.
This includes a wireless data communication for unrestricted mobility.
Subsequently the data are compared to the standard polysomnography data to extract vital signs or for example to recognize possible phases of sleep apnoea.
The goal in future refering to preventive medical monitoring will be early detection of risk factors for patient's health and improvement of living conditions.
Studientyp
Interventionell
Einschreibung (Tatsächlich)
8
Phase
- Unzutreffend
Kontakte und Standorte
Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.
Studienorte
-
-
North Rhine Westphalia
-
Aachen, North Rhine Westphalia, Deutschland, 52074
- Neurological Clinic , University Hospital
-
-
Teilnahmekriterien
Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.
Zulassungskriterien
Studienberechtigtes Alter
18 Jahre und älter (Erwachsene, Älterer Erwachsener)
Akzeptiert gesunde Freiwillige
Nein
Studienberechtigte Geschlechter
Alle
Beschreibung
Inclusion Criteria:
- patients > 18 years who routinely have to undergo a polysomnography night
- sleep apnoea patient
- able to give informed consent
Exclusion Criteria:
- dementia
- cochlea implant
- severe lung diseases
- allergy against material of the sensor
- inflammation of the middle ear
- inflammation of auditory canal
- occlusion because of cerumen
- electric implants
Studienplan
Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.
Wie ist die Studie aufgebaut?
Designdetails
- Hauptzweck: Grundlegende Wissenschaft
- Zuteilung: N / A
- Interventionsmodell: Einzelgruppenzuweisung
- Maskierung: Keine (Offenes Etikett)
Waffen und Interventionen
Teilnehmergruppe / Arm |
Intervention / Behandlung |
|---|---|
|
Experimental: Device: in-ear sensor
Patients who routinely undergo a polysomnography night (1 night) are monitored via in-ear sensor which will be embedded in the auditory canal.
During this night vital signs parameters are monitored, processed and subsequently compared to the polysomnography data.
|
Long term vital signs parameters like heart rate, heart rate variability, breathing and oxygen saturation are measured via in- ear sensor system during 1 polysomnographic night
Andere Namen:
|
Was misst die Studie?
Primäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Extraction of vital signs out of measurement data via individually formed in-ear sensor system in comparison to standard polysomnography data in sleep laboratory
Zeitfenster: one night
|
during one polysomnographic night in sleep laboratory the patient will receive the LAVIMO in- ear sensor system and vital parameters like heart rate, heart rate variability, breathing and oxygen saturation will be monitored.
Subsequently the data will be processed and compared to the standard polysomnographic data
|
one night
|
Mitarbeiter und Ermittler
Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.
Sponsor
Ermittler
- Hauptermittler: Johannes Schiefer, MD, Neurological Clinic, University Hospital Aachen
Studienaufzeichnungsdaten
Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.
Haupttermine studieren
Studienbeginn
1. Januar 2012
Primärer Abschluss (Tatsächlich)
1. Februar 2013
Studienabschluss (Tatsächlich)
1. Februar 2013
Studienanmeldedaten
Zuerst eingereicht
20. Juni 2012
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
20. Juni 2012
Zuerst gepostet (Schätzen)
22. Juni 2012
Studienaufzeichnungsaktualisierungen
Letztes Update gepostet (Schätzen)
27. November 2013
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
26. November 2013
Zuletzt verifiziert
1. November 2013
Mehr Informationen
Begriffe im Zusammenhang mit dieser Studie
Schlüsselwörter
Zusätzliche relevante MeSH-Bedingungen
Andere Studien-ID-Nummern
- CTC-A_10-016
- EK 231/10 (Andere Kennung: Ethics Committee University Hospital Aachen)
Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .
Klinische Studien zur Schlafapnoe, obstruktiv
-
Haseki Training and Research HospitalNoch keine RekrutierungRichards-Campbell Sleep-Fragebogen (RCSQ)
-
ElsanEuropean Clinical Trial Experts Network; Polyclinique PoitiersAbgeschlossenObstruktives Schlafapnoe-Syndrom | Hypnose | Drug Induce Sleep EndoscopyFrankreich
-
Brigham and Women's HospitalCharite University, Berlin, Germany; Stanford UniversityBeendetSchlafstörungen, intrinsisch | Schlaf-Wach-Störungen | Schlafstörungen, zirkadianer Rhythmus | Fortgeschrittenes Schlafphasensyndrom (ASPS) | Verzögertes Schlafphasensyndrom | Schichtarbeits-Schlafstörung | Verzögerte Schlafphase | Nicht-24-Stunden-Schlaf-Wach-Störung | Fortgeschrittenes Schlafphasensyndrom und andere BedingungenVereinigte Staaten
Klinische Studien zur LAVIMO in- ear sensor system
-
Starkey Laboratories, IncClinimark, LLCZurückgezogen