Pre-operative Radiological Measurement to Assess Femur Rotational Alignment
Pre-operative Radiological Measurement of Proximal Tibia Angle to Assess Femur Rotational Alignment in Total Knee Arthroplasty
Purpose: This study outlines the benefits of the proximal tibia angle (PTA) in evaluation of the pre-operative individual condylar twist angle (CTA) in total knee arthroplasty.
Methods: Condylar twist angle and proximal tibia angle were obtained from 33 female healthy participants using computed tomography (CT). The CTA, angle between clinical transepicondylar axis and posterior condylar line were measured. The PTA is the angle formed between the mechanical axis of the tibia and tibia plateau line. The correlation between the CTA and the PTA was analyzed statistically with the linear regression.
Studienübersicht
Status
Bedingungen
Studientyp
Einschreibung (Voraussichtlich)
Kontakte und Standorte
Studienorte
-
-
-
Xi'an, China
- Rekrutierung
- Hong-hui Hospital
-
Kontakt:
- Qiang He, MD
- Telefonnummer: 02983860818
-
-
Shanxi
-
Xi'an, Shanxi, China, 710054
- Rekrutierung
- Honghui hospital
-
Kontakt:
- Qiang He, MD
- Telefonnummer: 02983860818
- E-Mail: heqianghonghui@163.com
-
-
Teilnahmekriterien
Zulassungskriterien
Studienberechtigtes Alter
Akzeptiert gesunde Freiwillige
Studienberechtigte Geschlechter
Probenahmeverfahren
Studienpopulation
Beschreibung
Inclusion Criteria:
- Osteoarthritis Varus knee deformity
Exclusion Criteria:
- Rheumatoid arthritis valgus knee OA previous knee surgeries posttraumatic arthritis
Studienplan
Wie ist die Studie aufgebaut?
Designdetails
Kohorten und Interventionen
Gruppe / Kohorte |
|---|
|
CT
Measured with computed tomography
|
|
plain Radiography
Measured with plain Radiography
|
Was misst die Studie?
Primäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
proximal tibia angle (PTA)
Zeitfenster: Four months
|
The PTA is the angle formed between the mechanical axis of the tibia and tibia plateau line.
|
Four months
|
Sekundäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Condylar twist angle (CTA)
Zeitfenster: Four months
|
The CTA is the angle between clinical transepicondylar axis and posterior condylar line
|
Four months
|
Mitarbeiter und Ermittler
Sponsor
Ermittler
- Studienleiter: Jianbing Ma, MD, Honghui hospital
Publikationen und hilfreiche Links
Allgemeine Veröffentlichungen
- Kanekasu K, Kondo M, Kadoya Y. Axial radiography of the distal femur to assess rotational alignment in total knee arthroplasty. Clin Orthop Relat Res. 2005 May;(434):193-7. doi: 10.1097/01.blo.0000156819.24866.8b.
- Savin L, Botez P, Mihailescu D, Predescu V, Grierosu C. Pre-operative radiological measurement of femoral rotation for prosthetic positioning in total knee arthroplasty. Int Orthop. 2016 Sep;40(9):1855-60. doi: 10.1007/s00264-015-3110-2. Epub 2016 Jan 23.
- Kobayashi H, Aratake M, Akamatsu Y, Mitsugi N, Taki N, Saito T. Reproducibility of condylar twist angle measurement using computed tomography and axial radiography of the distal femur. Orthop Traumatol Surg Res. 2014 Dec;100(8):885-90. doi: 10.1016/j.otsr.2014.07.025. Epub 2014 Nov 20.
Studienaufzeichnungsdaten
Haupttermine studieren
Studienbeginn
Primärer Abschluss (Voraussichtlich)
Studienabschluss (Voraussichtlich)
Studienanmeldedaten
Zuerst eingereicht
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst gepostet (Schätzen)
Studienaufzeichnungsaktualisierungen
Letztes Update gepostet (Schätzen)
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Zuletzt verifiziert
Mehr Informationen
Begriffe im Zusammenhang mit dieser Studie
Andere Studien-ID-Nummern
- XianHongHuiH
Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .