- ICH GCP
- Register voor klinische proeven in de VS.
- Klinische proef NCT02817737
Pre-operative Radiological Measurement to Assess Femur Rotational Alignment
Pre-operative Radiological Measurement of Proximal Tibia Angle to Assess Femur Rotational Alignment in Total Knee Arthroplasty
Purpose: This study outlines the benefits of the proximal tibia angle (PTA) in evaluation of the pre-operative individual condylar twist angle (CTA) in total knee arthroplasty.
Methods: Condylar twist angle and proximal tibia angle were obtained from 33 female healthy participants using computed tomography (CT). The CTA, angle between clinical transepicondylar axis and posterior condylar line were measured. The PTA is the angle formed between the mechanical axis of the tibia and tibia plateau line. The correlation between the CTA and the PTA was analyzed statistically with the linear regression.
Studie Overzicht
Toestand
Conditie
Studietype
Inschrijving (Verwacht)
Contacten en locaties
Studiecontact
- Naam: Qiang He, MD
- Telefoonnummer: 13572887175
- E-mail: heqianghonghui@163.com
Studie Locaties
-
-
-
Xi'an, China
- Werving
- Hong-hui Hospital
-
Contact:
- Qiang He, MD
- Telefoonnummer: 02983860818
-
-
Shanxi
-
Xi'an, Shanxi, China, 710054
- Werving
- Honghui hospital
-
Contact:
- Qiang He, MD
- Telefoonnummer: 02983860818
- E-mail: heqianghonghui@163.com
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
Accepteert gezonde vrijwilligers
Geslachten die in aanmerking komen voor studie
Bemonsteringsmethode
Studie Bevolking
Beschrijving
Inclusion Criteria:
- Osteoarthritis Varus knee deformity
Exclusion Criteria:
- Rheumatoid arthritis valgus knee OA previous knee surgeries posttraumatic arthritis
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
Cohorten en interventies
Groep / Cohort |
---|
CT
Measured with computed tomography
|
plain Radiography
Measured with plain Radiography
|
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
---|---|---|
proximal tibia angle (PTA)
Tijdsspanne: Four months
|
The PTA is the angle formed between the mechanical axis of the tibia and tibia plateau line.
|
Four months
|
Secundaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
---|---|---|
Condylar twist angle (CTA)
Tijdsspanne: Four months
|
The CTA is the angle between clinical transepicondylar axis and posterior condylar line
|
Four months
|
Medewerkers en onderzoekers
Sponsor
Onderzoekers
- Studie directeur: Jianbing Ma, MD, Honghui hospital
Publicaties en nuttige links
Algemene publicaties
- Kanekasu K, Kondo M, Kadoya Y. Axial radiography of the distal femur to assess rotational alignment in total knee arthroplasty. Clin Orthop Relat Res. 2005 May;(434):193-7. doi: 10.1097/01.blo.0000156819.24866.8b.
- Savin L, Botez P, Mihailescu D, Predescu V, Grierosu C. Pre-operative radiological measurement of femoral rotation for prosthetic positioning in total knee arthroplasty. Int Orthop. 2016 Sep;40(9):1855-60. doi: 10.1007/s00264-015-3110-2. Epub 2016 Jan 23.
- Kobayashi H, Aratake M, Akamatsu Y, Mitsugi N, Taki N, Saito T. Reproducibility of condylar twist angle measurement using computed tomography and axial radiography of the distal femur. Orthop Traumatol Surg Res. 2014 Dec;100(8):885-90. doi: 10.1016/j.otsr.2014.07.025. Epub 2014 Nov 20.
Studie record data
Bestudeer belangrijke data
Studie start
Primaire voltooiing (Verwacht)
Studie voltooiing (Verwacht)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Schatting)
Updates van studierecords
Laatste update geplaatst (Schatting)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Andere studie-ID-nummers
- XianHongHuiH
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .
Klinische onderzoeken op Totale knievervanging
-
Smith & Nephew, Inc.VoltooidJourney II BCS Total Knee-systeemVerenigde Staten, België, Nieuw-Zeeland
-
Smith & Nephew, Inc.Nor Consult, LLCVoltooidJourney II XR Total Knee-systeemVerenigde Staten
-
Smith & Nephew, Inc.Nor ConsultVoltooidJourney II CR Total Knee-systeemVerenigde Staten
-
ACE Running LLCAir ForceNog niet aan het werven
-
Université Catholique de LouvainActief, niet wervend
-
Riphah International UniversityVoltooidRunner's KneePakistan
-
Bispebjerg HospitalVoltooidPatellaire Tendinopathie / Jumpers KneeDenemarken