- ICH GCP
- Rejestr badań klinicznych w USA
- Badanie kliniczne NCT02817737
Pre-operative Radiological Measurement to Assess Femur Rotational Alignment
Pre-operative Radiological Measurement of Proximal Tibia Angle to Assess Femur Rotational Alignment in Total Knee Arthroplasty
Purpose: This study outlines the benefits of the proximal tibia angle (PTA) in evaluation of the pre-operative individual condylar twist angle (CTA) in total knee arthroplasty.
Methods: Condylar twist angle and proximal tibia angle were obtained from 33 female healthy participants using computed tomography (CT). The CTA, angle between clinical transepicondylar axis and posterior condylar line were measured. The PTA is the angle formed between the mechanical axis of the tibia and tibia plateau line. The correlation between the CTA and the PTA was analyzed statistically with the linear regression.
Przegląd badań
Status
Warunki
Typ studiów
Zapisy (Oczekiwany)
Kontakty i lokalizacje
Lokalizacje studiów
-
-
-
Xi'an, Chiny
- Rekrutacyjny
- Hong-hui Hospital
-
Kontakt:
- Qiang He, MD
- Numer telefonu: 02983860818
-
-
Shanxi
-
Xi'an, Shanxi, Chiny, 710054
- Rekrutacyjny
- Honghui hospital
-
Kontakt:
- Qiang He, MD
- Numer telefonu: 02983860818
- E-mail: heqianghonghui@163.com
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Wiek uprawniający do nauki
Akceptuje zdrowych ochotników
Płeć kwalifikująca się do nauki
Metoda próbkowania
Badana populacja
Opis
Inclusion Criteria:
- Osteoarthritis Varus knee deformity
Exclusion Criteria:
- Rheumatoid arthritis valgus knee OA previous knee surgeries posttraumatic arthritis
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
Kohorty i interwencje
Grupa / Kohorta |
---|
CT
Measured with computed tomography
|
plain Radiography
Measured with plain Radiography
|
Co mierzy badanie?
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
---|---|---|
proximal tibia angle (PTA)
Ramy czasowe: Four months
|
The PTA is the angle formed between the mechanical axis of the tibia and tibia plateau line.
|
Four months
|
Miary wyników drugorzędnych
Miara wyniku |
Opis środka |
Ramy czasowe |
---|---|---|
Condylar twist angle (CTA)
Ramy czasowe: Four months
|
The CTA is the angle between clinical transepicondylar axis and posterior condylar line
|
Four months
|
Współpracownicy i badacze
Sponsor
Śledczy
- Dyrektor Studium: Jianbing Ma, MD, Honghui hospital
Publikacje i pomocne linki
Publikacje ogólne
- Kanekasu K, Kondo M, Kadoya Y. Axial radiography of the distal femur to assess rotational alignment in total knee arthroplasty. Clin Orthop Relat Res. 2005 May;(434):193-7. doi: 10.1097/01.blo.0000156819.24866.8b.
- Savin L, Botez P, Mihailescu D, Predescu V, Grierosu C. Pre-operative radiological measurement of femoral rotation for prosthetic positioning in total knee arthroplasty. Int Orthop. 2016 Sep;40(9):1855-60. doi: 10.1007/s00264-015-3110-2. Epub 2016 Jan 23.
- Kobayashi H, Aratake M, Akamatsu Y, Mitsugi N, Taki N, Saito T. Reproducibility of condylar twist angle measurement using computed tomography and axial radiography of the distal femur. Orthop Traumatol Surg Res. 2014 Dec;100(8):885-90. doi: 10.1016/j.otsr.2014.07.025. Epub 2014 Nov 20.
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów
Zakończenie podstawowe (Oczekiwany)
Ukończenie studiów (Oczekiwany)
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Oszacować)
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Oszacować)
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Inne numery identyfikacyjne badania
- XianHongHuiH
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .
Badania kliniczne na Całkowita wymiana kolana
-
Smith & Nephew, Inc.ZakończonyJourney II BCS Total Knee SystemStany Zjednoczone, Belgia, Nowa Zelandia
-
Smith & Nephew, Inc.Nor ConsultZakończonyJourney II CR Total Knee SystemStany Zjednoczone
-
Smith & Nephew, Inc.Nor Consult, LLCZakończonyJourney II XR Total Knee SystemStany Zjednoczone