Effects of Supplemental Oxygen Delivered by a Portable Oxygen Concentrator Compared to a Liquid Oxygen Device in COPD

14. Februar 2018 aktualisiert von: Klaus Kenn, Schön Klinik Berchtesgadener Land

Effects of Supplemental Oxygen Delivered by a Portable Oxygen Concentrator Compared to a Liquid Oxygen Device in Hypoxemic COPD Patients at Rest

The aim of this study is to investigate the effects of supplemental oxygen on blood oxygenation at rest in Patients with severe to very severe COPD comparing the portable oxygen concentrator (Activox™ 4L) to a liquid continuous oxygen device (Companion®).

Studienübersicht

Detaillierte Beschreibung

It has been proven that supplemental oxygen increases oxygen saturation and reduces dyspnea in hypoxemic COPD Patients. There are different oxygen delivery systems available, some of them operating with liquid oxygen and others by concentrating the ambient air (concentrators). An advantage of the concentrator system is, that there is no refill required, but only a power plug and plug socket, enabling the patient for higher mobility and to be more autonomous. There are only few publications about whether portable oxygen concentrators have a comparable efficiency on oxygen saturation to liquid oxygen devices with continuous flow (LOD) or not. Until now there are no official recommendations about how to convert the oxygen flow rate for LOD (liter per minute) into the corresponding level of the POC.

Therefore, we investigate the comparability of the portable oxygen concentrator Activox™ 4L (POC) to a liquid oxygen device (Companion®) in 30 hypoxemic COPD patients at rest.

As a baseline assessment, the patients will receive a bodyplethysmography, blood gas analysis without using supplemental oxygen and an evaluation of the diffusion capacity of the lung for CO.

The study will be conducted on 2 consecutive days. 15 patients will be randomized into two different groups: First group will start with POC and will continue the following day with LOD; The second group will start with LOD and continue with POC (cross-over design). All patients will use the same oxygen devices during the study assessments (LOD: Companion 1000 (CE 0050), Chart Industries Inc., Garfiel Heights, OH, USA; POC: Activox™ 4L, Inovalabs Inc., Texas, USA). On both days of the study, patients will be connected to one of the two systems via nasal cannula for a total time period of 40 minutes, while the patient remains in a sitting position without talking. The oxygen flow rate starts at 1liter/min (LOD) or Level 1 (POC) and will be increased every 10 minutes to the next higher level until the maximum of 4l/min (LOD) or level 4 (POC) is reached. Blood gases were taken and breathing frequency will be recorded at the end of each Oxygen Level.

Studientyp

Interventionell

Einschreibung (Tatsächlich)

20

Phase

  • Unzutreffend

Kontakte und Standorte

Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.

Studienorte

      • Schoenau Am Koenigssee, Deutschland
        • Schoen Klinik Berchtesgadener Land

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

40 Jahre bis 80 Jahre (Erwachsene, Älterer Erwachsener)

Akzeptiert gesunde Freiwillige

Nein

Studienberechtigte Geschlechter

Alle

Beschreibung

Inclusion Criteria:

  • COPD patients with hypoxemia at rest (paO2 < 55 or 60 mmHg, according to the recent supplemental oxygen guidelines [Hadringe, M., et al., British Thoracic Society guidelines for home oxygen use in adults. Thorax, 2015. 70 Suppl 1: p. i1-43.]
  • Participation in an inpatient pulmonary rehabilitation program (Schön Klinik BGL)
  • Written informed consent

Exclusion Criteria:

  • The Need of more than 4 Liter/min Oxygen at rest to achieve PaO2 > 55 or 60mmHg
  • Signs of acute exacerbation
  • General exclusion criteria for exercise tests, e.g. acute coronary syndrome, acute myo- or pericarditis, acute lung embolism, pulmonary infarction, acute uncontrolled heart insufficiency

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

  • Hauptzweck: Behandlung
  • Zuteilung: Zufällig
  • Interventionsmodell: Crossover-Aufgabe
  • Maskierung: Doppelt

Waffen und Interventionen

Teilnehmergruppe / Arm
Intervention / Behandlung
Experimental: COPD patients with delivery order 1, 2
Patients will use two different Oxygen devices at rest (1.liquid oxygen device (Companion R), 2. portable Oxygen concentrator (Activox TM 4L))
This oxygen Supplementation is used in special order
Andere Namen:
  • Companion 1000 Chart Industries, Inc. Garfield Heights, USA
This oxygen Supplementation is used in special order
Andere Namen:
  • Activox™ 4L, Inovalabs Inc., Texas, USA
Experimental: COPD patients with delivery order 2,1
Patients will use two different Oxygen devices at rest (1. portable Oxygen concentrator (Activox TM 4L), 2. liquid oxygen device (Companion R))
This oxygen Supplementation is used in special order
Andere Namen:
  • Companion 1000 Chart Industries, Inc. Garfield Heights, USA
This oxygen Supplementation is used in special order
Andere Namen:
  • Activox™ 4L, Inovalabs Inc., Texas, USA

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Difference between LOD and POC in Partial pressure of oxygen levels
Zeitfenster: after 10 minutes of each LOD step compared to 10 minutes of each POC step
PO2 values between LOD and POC at comparable Levels of oxygen supply (1liter/minute LOD will be compared to Level 1 of POC until 4liters/Minute LOD to Level 4 of POC)
after 10 minutes of each LOD step compared to 10 minutes of each POC step

Sekundäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Difference between LOD and POC in Partial pressure of carbon dioxide levels
Zeitfenster: after 10 minutes of each LOD step compared to 10 minutes of each POC step
PCO2 values between LOD and POC at comparable Levels of oxygen supply (1liter/minute LOD will be compared to Level 1 of POC until 4liters/Minute LOD to Level 4 of POC)
after 10 minutes of each LOD step compared to 10 minutes of each POC step
Change of partial pressure of Oxygen from one POC step to the next step
Zeitfenster: after 10 minutes of one POC step compared to after 10 minutes of the next POC step
Change in PO2 values from e.g. POC step 1 to POC step 2, step 2 to 3 etc.
after 10 minutes of one POC step compared to after 10 minutes of the next POC step
Change of partial pressure of carbon dioxide from one POC step to the next step
Zeitfenster: after 10 minutes of one POC step compared to after 10 minutes of the next POC step
Change in PCO2 values between e.g. POC step 1 to POC step 2, step 2 to 3 etc.
after 10 minutes of one POC step compared to after 10 minutes of the next POC step

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn (Tatsächlich)

2. Mai 2017

Primärer Abschluss (Tatsächlich)

15. September 2017

Studienabschluss (Tatsächlich)

15. September 2017

Studienanmeldedaten

Zuerst eingereicht

30. Mai 2017

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

30. Mai 2017

Zuerst gepostet (Tatsächlich)

2. Juni 2017

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Tatsächlich)

15. Februar 2018

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

14. Februar 2018

Zuletzt verifiziert

1. Februar 2018

Mehr Informationen

Begriffe im Zusammenhang mit dieser Studie

Andere Studien-ID-Nummern

  • ActivoxTitration

Plan für individuelle Teilnehmerdaten (IPD)

Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?

UNENTSCHIEDEN

Arzneimittel- und Geräteinformationen, Studienunterlagen

Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt

Nein

Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt

Nein

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .