mFFE MRI Versus CT for Cortical Bone Evaluation in Knee Osteoarthritis

14. September 2026 aktualisiert von: Fatima Mahmoud Hammad Eltony, Assiut University

Beyond Conventional MRI: Multi-Echo Fast Field Echo (mFFE) MRI for Cortical Bone Evaluation in Knee Osteoarthritis Compared With CT

This cross-sectional study aims to evaluate the accuracy of multi-echo fast field echo (mFFE) MRI in depicting cortical bone changes in knee osteoarthritis compared with CT.

Studienübersicht

Status

Noch keine Rekrutierung

Detaillierte Beschreibung

Knee osteoarthritis involves microstructural alterations in subchondral and cortical bone. Conventional MRI has limitations in visualizing cortical bone due to short T2 relaxation times. Multi-echo fast field echo (mFFE) sequences can produce CT-like images of cortical bone without ionizing radiation.

This observational study will include patients aged 40 years or older with clinically suspected or confirmed knee osteoarthritis. All participants will undergo both mFFE MRI and CT of the knee. The accuracy of mFFE MRI in detecting cortical bone degenerative changes will be compared with CT as the reference standard.

Studientyp

Beobachtungs

Einschreibung (Geschätzt)

80

Kontakte und Standorte

Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.

Studienkontakt

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

  • Erwachsene
  • Älterer Erwachsener

Akzeptiert gesunde Freiwillige

Nein

Probenahmeverfahren

Nicht-Wahrscheinlichkeitsprobe

Studienpopulation

Patients aged 40 years or older with clinically suspected or confirmed knee osteoarthritis attending the Diagnostic and Interventional Radiology Department at Assiut University Hospital.

Beschreibung

Inclusion Criteria:

  • - Age 40 years or older
  • Clinically suspected or confirmed knee osteoarthritis
  • Able and willing to provide informed consent

Exclusion Criteria:

  • - Implanted electronic devices (pacemakers, ICDs, neurostimulators, cochlear implants)
  • Metallic foreign bodies in the eyes or orbits
  • Ferromagnetic cerebral aneurysm clips
  • Implantable infusion pumps
  • Pregnancy

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

Kohorten und Interventionen

Gruppe / Kohorte
Single cohort: Patients with knee osteoarthritis
Patients aged 40 years or older with knee osteoarthritis who will undergo both multi-echo fast field echo (mFFE) MRI and CT of the knee for comparison of cortical bone evaluation.

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Diagnostic accuracy of mFFE MRI for cortical bone changes
Zeitfenster: Baseline
Overall diagnostic accuracy percentage of multi-echo fast field echo MRI in detecting cortical bone degenerative changes in knee osteoarthritis, using CT as the reference standard
Baseline

Sekundäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Sensitivity of mFFE MRI for cortical bone changes
Zeitfenster: Baseline
Sensitivity percentage of multi-echo fast field echo MRI in detecting cortical bone degenerative changes in knee osteoarthritis, using CT as the reference standard
Baseline
Specificity of mFFE MRI for cortical bone changes
Zeitfenster: Baseline
Specificity percentage of multi-echo fast field echo MRI in detecting cortical bone degenerative changes in knee osteoarthritis, using CT as the reference standard
Baseline
Detection of subchondral sclerosis
Zeitfenster: Baseline
Number of cases in which mFFE MRI correctly identifies subchondral sclerosis compared with CT
Baseline
Detection of osteophytes
Zeitfenster: Baseline
Number of cases in which mFFE MRI correctly identifies osteophytes compared with CT
Baseline
Detection of joint space narrowing
Zeitfenster: Baseline
Number of cases in which mFFE MRI correctly identifies joint space narrowing compared with CT
Baseline
Image quality score
Zeitfenster: Baseline
Mean subjective image quality score of mFFE MRI for cortical bone visualization on a predefined scale from 1 to 5, with higher scores indicating better image quality
Baseline

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Ermittler

  • Studienstuhl: Ehab M Mohammed, prof, Diagnostic and interventional radiology Department, Assiut University Hospitals

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn (Geschätzt)

15. September 2026

Primärer Abschluss (Geschätzt)

20. September 2027

Studienabschluss (Geschätzt)

20. Februar 2028

Studienanmeldedaten

Zuerst eingereicht

14. September 2026

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

14. September 2026

Zuerst gepostet (Tatsächlich)

18. September 2026

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Tatsächlich)

18. September 2026

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

14. September 2026

Zuletzt verifiziert

1. September 2026

Mehr Informationen

Begriffe im Zusammenhang mit dieser Studie

Andere Studien-ID-Nummern

  • mFFE-MRI-KneeOA-Assiut-2026

Arzneimittel- und Geräteinformationen, Studienunterlagen

Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt

Nein

Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt

Nein

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .