Contrast-enhanced spectral mammography (CESM) versus breast magnetic resonance imaging (MRI): A retrospective comparison in 66 breast lesions

L Li, R Roth, P Germaine, S Ren, M Lee, K Hunter, E Tinney, L Liao, L Li, R Roth, P Germaine, S Ren, M Lee, K Hunter, E Tinney, L Liao

Abstract

Objective: The purpose of this study was to retrospectively compare the diagnostic performance of contrast-enhanced spectral mammography (CESM) with that of breast magnetic resonance imaging (BMRI) in breast cancer detection using parameters, including sensitivity, positive predictive value (PPV), lesion size, morphology, lesion and background enhancement, and examination time.

Materials and methods: A total of 48 women (mean age, 56years±10.6 [SD]) with breast lesions detected between October 2012 and March 2014 were included. Both CESM and BMRI were performed for each patient within 30 days. The enhancement intensity of lesions and breast background parenchyma was subjectively assessed for both modalities and was quantified for comparison. Statistical significance was analyzed using paired t-test for mean size of index lesions in all malignant breasts (an index lesion defined as the largest lesion in each breast), and a mean score of enhancement intensity for index lesions and breast background. PPV, sensitivity, and accuracy were calculated for both CESM and BMRI. The average duration time of CESM and MRI examinations was also compared.

Results: A total of 66 lesions were identified, including 62 malignant and 4 benign lesions. Both CESM and BMRI demonstrated a sensitivity of 100% for detection of breast cancer. There was no statistically significant difference between the mean size of index lesions (P=0.108). The enhancement intensity of breast background was significantly lower for CESM than for BMRI (P<0.01). The mean score of enhancement intensity of index lesions on CESM was significantly less than that for BMRI (P<0.01). The smallest lesion that was detected by both modalities measured 4mm. CESM had a higher PPV than BMRI (P>0.05). The average examination time for CESM was significantly shorter than that of BMRI (P<0.01).

Conclusion: CESM has similar sensitivity than BMRI in breast cancer detection, with higher PPV and less background enhancement. CESM is associate with significantly shorter exam time thus a more accessible alternative to BMRI, and has the potential to play an important tool in breast cancer detection and staging.

Keywords: Breast cancer diagnosis; Comparative studies; Contrast-enhanced spectral mammography (CESM); Magnetic resonance imaging (MRI).

Copyright © 2016 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

Source: PubMed

3