Tissue Quality Comparison Between Heparinized Wet Suction and Dry Suction in Endoscopic Ultrasound-Fine Needle Biopsy of Solid Pancreatic Masses: A Randomized Crossover Study
Meng-Ying Lin, Cheng-Lin Wu, Yung-Yeh Su, Chien-Jui Huang, Wei-Lun Chang, Bor-Shyang Sheu, Meng-Ying Lin, Cheng-Lin Wu, Yung-Yeh Su, Chien-Jui Huang, Wei-Lun Chang, Bor-Shyang Sheu
Abstract
Background/aims: A high-quality sample allows for next-generation sequencing and the administration of more tailored precision medicine treatments. We aimed to evaluate whether heparinized wet suction can obtain higher quality samples than the standard dry-suction method during endoscopic ultrasound (EUS)-guided biopsy of pancreatic masses.
Methods: A prospective randomized crossover study was conducted. Patients with a solid pancreatic mass were randomly allocated to receive either heparinized wet suction first or dry suction first. For each method, two needle passes were made, followed by a switch to the other method for a total of four needle punctures. The primary outcome was the aggregated white tissue length. Histological blood contamination, diagnostic performance and adverse events were analyzed as secondary outcomes. In addition, the correlation between white tissue length and the extracted DNA amount was analyzed.
Results: A total of 50 patients were enrolled, and 200 specimens were acquired (100 with heparinized wet suction and 100 with dry suction), with one minor bleeding event. The heparinized wet suction approach yielded specimens with longer aggregated white tissue length (11.07 mm vs 7.96 mm, p=0.001) and less blood contamination (p=0.008). A trend towards decreasing tissue quality was observed for the 2nd pass of the dry-suction method, leading to decreased diagnostic sensitivity and accuracy, although the accumulated diagnostic performance was comparable between the two suction methods. The amount of extracted DNA correlated positively to the white tissue length (p=0.001, Spearman̕s ρ=0.568).
Conclusions: Heparinized wet suction for EUS tissue acquisition of solid pancreatic masses can yield longer, bloodless, DNA-rich tissue without increasing the incidence of adverse events (ClinicalTrials.gov. identifier NCT04707560).
Keywords: Biopsy; DNA; Endoscopic ultrasound-guided fine needle aspiration; Heparin; Pancreatic neoplasms; fine-needle.
Conflict of interest statement
CONFLICTS OF INTEREST
No potential conflict of interest relevant to this article was reported.
Figures
References
- Adler DG, Muthusamy VR, Ehrlich DS, et al. A multicenter evaluation of a new EUS core biopsy needle: experience in 200 patients. Endosc Ultrasound. 2019;8:99–104. doi: 10.4103/eus.eus_53_17.
- van Dam JL, Janssen QP, Besselink MG, et al. Neoadjuvant therapy or upfront surgery for resectable and borderline resectable pancreatic cancer: a meta-analysis of randomised controlled trials. Eur J Cancer. 2022;160:140–149. doi: 10.1016/j.ejca.2021.10.023.
- National Comprehensive Cancer Network (NCCN), author Pancreatic adenocarcinoma version 2.2021 [Internet] NCCN; Plymouth Meeting: c2021. [cited 2021 Feb 25]. Available from: .
- Lee YS, Lee JC, Yang SY, Kim J, Hwang JH. Neoadjuvant therapy versus upfront surgery in resectable pancreatic cancer according to intention-to-treat and per-protocol analysis: a systematic review and meta-analysis. Sci Rep. 2019;9:15662. doi: 10.1038/s41598-019-52167-9.
- Neoptolemos JP, Kleeff J, Michl P, Costello E, Greenhalf W, Palmer DH. Therapeutic developments in pancreatic cancer: current and future perspectives. Nat Rev Gastroenterol Hepatol. 2018;15:333–348. doi: 10.1038/s41575-018-0005-x.
- Vilmann P, Jacobsen GK, Henriksen FW, Hancke S. Endoscopic ultrasonography with guided fine needle aspiration biopsy in pancreatic disease. Gastrointest Endosc. 1992;38:172–173. doi: 10.1016/S0016-5107(92)70385-X.
- Micames C, Jowell PS, White R, et al. Lower frequency of peritoneal carcinomatosis in patients with pancreatic cancer diagnosed by EUS-guided FNA vs. percutaneous FNA. Gastrointest Endosc. 2003;58:690–695. doi: 10.1016/S0016-5107(03)02009-1.
- Okasha HH, Naga MI, Esmat S, et al. Endoscopic ultrasound-guided fine needle aspiration versus percutaneous ultrasound-guided fine needle aspiration in diagnosis of focal pancreatic masses. Endosc Ultrasound. 2013;2:190–193. doi: 10.4103/2303-9027.121239.
- Cazacu IM, Luzuriaga Chavez AA, Saftoiu A, Vilmann P, Bhutani MS. A quarter century of EUS-FNA: progress, milestones, and future directions. Endosc Ultrasound. 2018;7:141–160. doi: 10.4103/eus.eus_19_18.
- Villa NA, Berzosa M, Wallace MB, Raijman I. Endoscopic ultrasound-guided fine needle aspiration: the wet suction technique. Endosc Ultrasound. 2016;5:17–20. doi: 10.4103/2303-9027.175877.
- Attam R, Arain MA, Bloechl SJ, et al. "Wet suction technique (WEST)": a novel way to enhance the quality of EUS-FNA aspirate. Results of a prospective, single-blind, randomized, controlled trial using a 22-gauge needle for EUS-FNA of solid lesions. Gastrointest Endosc. 2015;81:1401–1407. doi: 10.1016/j.gie.2014.11.023.
- Nakai Y, Isayama H, Chang KJ, et al. Slow pull versus suction in endoscopic ultrasound- guided fine-needle aspiration of pancreatic solid masses. Dig Dis Sci. 2014;59:1578–1585. doi: 10.1007/s10620-013-3019-9.
- Lee KY, Cho HD, Hwangbo Y, et al. Efficacy of 3 fine-needle biopsy techniques for suspected pancreatic malignancies in the absence of an on-site cytopathologist. Gastrointest Endosc. 2019;89:825–831. doi: 10.1016/j.gie.2018.10.042.
- Mok SRS, Diehl DL, Johal AS, et al. A prospective pilot comparison of wet and dry heparinized suction for EUS-guided liver biopsy (with videos) Gastrointest Endosc. 2018;88:919–925. doi: 10.1016/j.gie.2018.07.036.
- Chantrill LA, Nagrial AM, Watson C, et al. Precision medicine for advanced pancreas cancer: the Individualized Molecular Pancreatic Cancer Therapy (IMPaCT) trial. Clin Cancer Res. 2015;21:2029–2037. doi: 10.1158/1078-0432.CCR-15-0426.
- Goswami RS, Luthra R, Singh RR, et al. Identification of factors affecting the success of next-generation sequencing testing in solid tumors. Am J Clin Pathol. 2016;145:222–237. doi: 10.1093/ajcp/aqv023.
- Larson BK, Tuli R, Jamil LH, Lo SK, Deng N, Hendifar AE. Utility of endoscopic ultrasound-guided biopsy for next-generation sequencing of pancreatic exocrine malignancies. Pancreas. 2018;47:990–995. doi: 10.1097/MPA.0000000000001117.
- Park JK, Lee JH, Noh DH, et al. Factors of endoscopic ultrasound-guided tissue acquisition for successful next-generation sequencing in pancreatic ductal adenocarcinoma. Gut Liver. 2020;14:387–394. doi: 10.5009/gnl19011.
- Nieto J, Khaleel H, Challita Y, et al. EUS-guided fine-needle core liver biopsy sampling using a novel 19-gauge needle with modified 1-pass, 1 actuation wet suction technique. Gastrointest Endosc. 2018;87:469–475. doi: 10.1016/j.gie.2017.05.013.
- Iwashita T, Yasuda I, Mukai T, et al. Macroscopic on-site quality evaluation of biopsy specimens to improve the diagnostic accuracy during EUS-guided FNA using a 19-gauge needle for solid lesions: a single-center prospective pilot study (MOSE study) Gastrointest Endosc. 2015;81:177–185. doi: 10.1016/j.gie.2014.08.040.
- Lin MY, Wu CL, Kida M, Chang WL, Sheu BS. Confirming whether fine needle biopsy device shortens the learning curve of endoscopic ultrasound-guided tissue acquisition without rapid onsite evaluation. Clin Endosc. 2021;54:420–427. doi: 10.5946/ce.2020.184.
- Diehl DL, Mok S, Khara HS, Johal AS, Kirchner HL, Lin F. Heparin priming of EUS-FNA needles does not adversely affect tissue cytology or immunohistochemical staining. Endosc Int Open. 2018;6:E356–E362. doi: 10.1055/s-0043-121880.
- Hasan MK, Bang JY, Varadarajulu S. Diagnostic value of priming the endoscopic ultrasound-guided fine-needle aspiration needle with heparin to improve specimen quality. Dig Endosc. 2014;26:491. doi: 10.1111/den.12233.
- Bang JY, Navaneethan U, Hasan MK, Hawes R, Varadarajulu S. Endoscopic ultrasound-guided specimen collection and evaluation techniques affect diagnostic accuracy. Clin Gastroenterol Hepatol. 2018;16:1820–1828. doi: 10.1016/j.cgh.2018.03.004.
- Mohammad Alizadeh AH, Hadizadeh M, Padashi M, Shahbaazi S, Molaee M, Shariatpanahi ZV. Comparison of two techniques for endoscopic ultrasonography fine-needle aspiration in solid pancreatic mass. Endosc Ultrasound. 2014;3:174–178. doi: 10.4103/2303-9027.138790.
- Wang Y, Wang RH, Ding Z, et al. Wet- versus dry-suction techniques for endoscopic ultrasound-guided fine-needle aspiration of solid lesions: a multicenter randomized controlled trial. Endoscopy. 2020;52:995–1003. doi: 10.1055/a-1167-2214.
- Saxena P, El Zein M, Stevens T, et al. Stylet slow-pull versus standard suction for endoscopic ultrasound-guided fine-needle aspiration of solid pancreatic lesions: a multicenter randomized trial. Endoscopy. 2018;50:497–504. doi: 10.1055/s-0043-122381.
Source: PubMed