Absolute Reliability and Concurrent Validity of Hand-Held Dynamometry in Shoulder Rotator Strength Assessment: Systematic Review and Meta-Analysis

Claudio Chamorro, Miguel Arancibia, Benjamín Trigo, Leónidas Arias-Poblete, Daniel Jerez-Mayorga, Claudio Chamorro, Miguel Arancibia, Benjamín Trigo, Leónidas Arias-Poblete, Daniel Jerez-Mayorga

Abstract

The purpose of this study is to establish the absolute reliability between hand-held dynamometers (HHDs) and concurrent validity between HHDs and isokinetic dynamometers (IDs) in shoulder rotator strength assessment. The Medline, CINAHL, and Central databases were searched for relevant studies up to July 2020. Absolute reliability was determined by test-retest studies presenting standard error of measurement (SEM%) and/or minimal detectable change (MDC%) expressed as percentage of the mean. Studies considering intra-class correlation coefficient (ICC) between IDs and HHDs were considered for concurrent validity. The risk of bias and the methodological quality were evaluated according to COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN). Thirteen studies were included in the meta-analysis. Shoulder internal rotator strength assessment MDC% was 0.78%, 95% confidence interval (CI) -5.21 to 3.66, while shoulder external rotators MDC% was 3.29%, CI -2.69 to 9.27. ICC between devices was 0.94, CI (0.91 to 0.96) for shoulder internal rotators and 0.92, IC (0.88 to 0.97) for shoulder external rotators. Very high correlation was found for shoulder rotator torque assessment between HHDs and IDs. The COSMIN checklist classified the selected studies as adequate and inadequate.

Keywords: muscle strength; reliability; rotator cuff.

Conflict of interest statement

The authors declare no conflict of interest.

Figures

Figure 1
Figure 1
Flow chart of the manuscript selection process.
Figure 2
Figure 2
Absolute reliability for shoulder internal rotator strength assessment.
Figure 3
Figure 3
Absolute reliability for shoulder external rotator strength assessment.
Figure 4
Figure 4
Meta-analysis of concurrent validity for shoulder internal rotator strength assessment.
Figure 5
Figure 5
Meta-analysis of concurrent validity for shoulder external rotator strength assessment.

References

    1. Schrama P.P.M., Stenneberg M.S., Lucas C., Van Trijffel E. Intraexaminer reliability of hand-held dynamometry in the upper extremity: A systematic review. Arch. Phys. Med. Rehabil. 2014;95:2444–2469. doi: 10.1016/j.apmr.2014.05.019.
    1. Rabelo M., Nunes G.S., da Costa Amante N.M., de Noronha M., Fachin-Martins E. Reliability 364 of muscle strength assessment in chronic post-stroke hemiparesis: A systematic review and meta-analysis. Top. Stroke Rehabil. 2016;23:26–35. doi: 10.1179/1945511915Y.0000000008.
    1. Padulo J., Trajkovic N., Cular D., Grgantov Z., Madic D., Di Vico R., Traficante A., Alin L., Ardigo L.P., Russo L. Validity and reliability of isometric-bench for knee isometric assessment. Int. J. Environ. Res. Public Health. 2020;17:4326. doi: 10.3390/ijerph17124326.
    1. Dauty M., Delbrouck C., Huguet D., Rousseau B., Potiron-Josse M., Dubois C. Reproducibility of concentric and eccentric isokinetic strength of the shoulder rotators in normal subjects 40 to 55 years old. Isokin. Exerc. Sci. 2003;11:95–100. doi: 10.3233/IES-2003-0134.
    1. Martin H.J., Yule V., Syddall H.E., Dennison E.M., Cooper C., Aihie Sayer A. Is hand-held dynamometry useful for the measurement of quadriceps strength in older people? A comparison with the gold standard Bodex dynamometry. Gerontology. 2006;52:154–159. doi: 10.1159/000091824.
    1. Atkinson G., Nevill A.M. Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine. Sports Med. 1998;26:217–238. doi: 10.2165/00007256-199826040-00002.
    1. Hopkins W.G. Measures of reliability in sports medicine and science. Sports Med. 2000;30:1–15. doi: 10.2165/00007256-200030010-00001.
    1. Drouin J.M., Valovich-mcLeod T.C., Shultz S.J., Gansneder B.M., Perrin D.H. Reliability and validity of the Biodex system 3 pro isokinetic dynamometer velocity, torque and position measurements. Eur. J. Appl. Physiol. 2004;91:22–29.
    1. Stratford P.W. Getting more from the literature: Estimating the standard error of measurement from reliability studies. Physiother. Can. 2004;56:27–30. doi: 10.2310/6640.2004.15377.
    1. Edouard P., Samozino P., Julia M., Cervera S.G., Vanbiervliet W., Calmels P., Gremeaux V. Reliability of Isokinetic Assessment of Shoulder-Rotator Strength: A Systematic Review of the Effect of Position. J. Sport Rehabil. 2011;20:367–383. doi: 10.1123/jsr.20.3.367.
    1. Sorensen L., Oestergaard L.S., van Tulder M., Petersen A.K. Measurement properties of isokinetic dynamometry for assessment of shoulder muscle strength: A systematic review. Arch. Phys. Med. Rehabil. 2021;102:510–520. doi: 10.1016/j.apmr.2020.06.005.
    1. Mokkink L.B., de Vet H.C.W., Prinsen C.A.C. COSMIN Risk of Bias checklist for systematic reviews of Patient- Reported Outcome Measures. Qual. Life Res. 2018;27:1171–1179. doi: 10.1007/s11136-017-1765-4.
    1. Mokkink L.B., De Vet H.C.W., Prinsen C.A.C., Patrick D.L., Alonso J., Bouter L., Terwee C.B. COSMIN Risk of Bias checklist for systematic reviews of Patient-Reported Outcome Measures. Qual. Life Res. 2018;27:1171–1179. doi: 10.1007/s11136-017-1765-4.
    1. Terwee C.B., Bot S.D., de Boer M.R., van der Windt D.A., Knol D.L., Dekker J., Bouter L.M., de Vet H.C. Quality criteria were proposed for measurement properties of health status questionnaires. J. Clin. Epidemiol. 2007;60:34–42. doi: 10.1016/j.jclinepi.2006.03.012.
    1. Chamorro C., Armijo-Olivo S., De la Fuente C., Fuentes J., Chirosa L.J. Absolute reliability and concurrent validity of hand held dynamometry and isokinetic dynamometry in the hip, knee and ankle joint: Systematic review and meta-analysis. Open Med. 2017;12:359–375. doi: 10.1515/med-2017-0052.
    1. Holt K.L., Raper D.P., Boettcher C.E., Waddington G.S., Drew M.K. Hand-held dynamometry strength measures for internal and external rotation demonstrate superior reliability, lower minimal detectable change and higher correlation to isokinetic dynamometry than externally-fixed dynamometry of the shoulder. Phys. Ther. Sport Off. J. Assoc. Chart. Physiother. Sports Med. 2016;21:75–81. doi: 10.1016/j.ptsp.2016.07.001.
    1. Munro B.H. Statistical Methods for Health Care Research. Lippincott Williams & Wilkins; Alphen aan den Rijn, The Netherlands: 2005.
    1. McLaine S.J., Ginn K.A., Kitic C.M., Fell J.W., Bird M.-L. The Reliability of Strength Tests Performed In Elevated Shoulder Positions Using a Handheld Dynamometer. J. Sport Rehabil. 2016;25 doi: 10.1123/jsr.2015-0034.
    1. Fieseler G., Molitor T., Irlenbusch L., Delank K.-S., Laudner K.G., Hermassi S., Schwesig R. Intrarater reliability of goniometry and hand-held dynamometry for shoulder and elbow examinations in female team handball athletes and asymptomatic volunteers. Arch. Orthop. Trauma Surg. 2015;135:1719–1726. doi: 10.1007/s00402-015-2331-6.
    1. Conceicao A., Parraca J., Marinho D., Costa M., Louro H., Silva A., Batalha N. Assessment of isometric strength of the shoulder rotators in swimmers using a handheld dynamometer: A reliability study. Acta Bioeng. Biomech. 2018;20:114–119.
    1. Kolber M.J., Beekhuizen K., Cheng M.S.S., Fiebert I.M. The reliability of hand-held dynamometry in measuring isometric strength of the shoulder internal and external rotator musculature using a stabilization device. Physio. Theory Pract. 2007;23:119–124. doi: 10.1080/09593980701213032.
    1. Johansson F.R., Skillgate E., Lapauw M.L., Clijmans D., Deneulin V.P., Palmans T., Engineer H.K., Cools A.M. Measuring Eccentric Strength of the Shoulder External Rotators Using a Handheld Dynamometer: Reliability and Validity. J. Athl. Train. 2014;50:719–725. doi: 10.4085/1062-6050-49.3.72.
    1. Raza S. Reliability and Validity of EN-TreeM Dynamometer for Measurement of Shoulder Rotator Strength in Volleyball Players. J. Clin. Diagn. Res. 2016;10:YC05–YC09. doi: 10.7860/JCDR/2016/15578.7484.
    1. Vermeulen H.M., de Bock G.H., van Houwelingen H.C., van der Meer R.L., Mol M.C., Plus B.T., Rozing P.M., Vlieland T.V. A comparison of two portable dynamometers in the assessment of shoulder and elbow strength. Physiotherapy. 2005;91:101–112. doi: 10.1016/j.physio.2004.08.005.
    1. Katoh M. Test-retest reliability of isometric shoulder muscle strength measurement with a handheld dynamometer and belt. J. Phys. Ther. Sci. 2015;27:1719–1722. doi: 10.1589/jpts.27.1719.
    1. Grabowski P., Narveson M., Siegle S. Reliability, responsiveness, and criterion validity of the Kiio sensor, a new tool for assessment of muscle function. Mil. Med. 2017;182:26–31. doi: 10.7205/MILMED-D-16-00134.
    1. Bohannon R.W. Reference values for extremity muscle strength obtained by hand-held dynamometry from adults aged 20 to 79 years. Arch. Phys. Med. Rehabil. 1997;78:26–32. doi: 10.1016/S0003-9993(97)90005-8.
    1. Leggin B.G., Neuman R.M., Iannotti J.P., Williams G.R., Thompson E.C. Intrarater and interrater reliability of three isometric dynamometers in assessing shoulder strength. J. Shoulder Surg. 1996;5:18–24. doi: 10.1016/S1058-2746(96)80026-7.
    1. Chamorro C., de la Fuente C., Rubio J., Campos C., Chirosa L.J. Absolute reliability and concurrent validity of a novel electromechanical pulley dynamometer for measuring shoulder rotation isometric strength in asymptomatic subjects. Study conducted at Pontificia Universidad Católica, Santiago, Chile. J. Pak. Med. Assoc. 2019;69:1000–1005.
    1. Hébert L.J., Maltais D.B., Lepage C., Saulnier J., Crête M., Perron M. Isometric muscle strength in youth assessed by hand-held dynamometry: A feasibility, reliability, and validity study: A feasibility, reliability, and validity study. Pediatr. Phys. Ther. 2011;23:289–299. doi: 10.1097/PEP.0b013e318227ccff.
    1. Van Meeteren J., Roebroeck M.E., Stam H.J. Test-retest reliability in isokinetic muscle strength measurements of the shoulder. J. Rehabil. Med. 2002;34:91–95. doi: 10.1080/165019702753557890.
    1. Collado-Mateo D., Dominguez-Muñoz F.J., Batalha N., Parraça J., Tomas-Carus P., Adsuar J.C. Test-retest reliability of isokinetic arm strength measurements in competitive swimmers. J. Hum. Kinet. 2018;65:5–11. doi: 10.2478/hukin-2018-0035.
    1. Wikholm J.B., Bohannon R.W. Hand-held dynamometer measurements: Tester strength makes a difference. J. Orthop. Sports Phys. Ther. 1991;13:191–198. doi: 10.2519/jospt.1991.13.4.191.
    1. Bassett R.W., Browne A.O., Morrey B.F., An K.N. Glenohumeral muscle force and moment mechanics in a position of shoulder instability. J. Biomech. 1990;23:405–415. doi: 10.1016/0021-9290(90)90295-E.

Source: PubMed

3
Abonnieren