Clinimetric evaluation of active range of motion measures in patients with non-specific neck pain: a systematic review

Chantal H P de Koning, Sylvia P van den Heuvel, J Bart Staal, Bouwien C M Smits-Engelsman, Erik J M Hendriks, Chantal H P de Koning, Sylvia P van den Heuvel, J Bart Staal, Bouwien C M Smits-Engelsman, Erik J M Hendriks

Abstract

The study is to provide a critical analysis of the research literature on clinimetric properties of instruments that can be used in daily practice to measure active cervical range of motion (ACROM) in patients with non-specific neck pain. A computerized literature search was performed in Medline, Cinahl and Embase from 1982 to January 2007. Two reviewers independently assessed the clinimetric properties of identified instruments using a criteria list. The search identified a total of 33 studies, investigating three different types of measurement instruments to determine ACROM. These instruments were: (1) different types of goniometers/inclinometers, (2) visual estimation, and (3) tape measurements. Intra- and inter-observer reliability was demonstrated for the cervical range of motion instrument (CROM), Cybex electronic digital instrument (EDI-320) and a single inclinometer. The presence of agreement was assessed for the EDI-320 and a single inclinometer. The CROM received a positive rating for construct validity. When clinical acceptability is taken into account both the CROM and the single inclinometer can be considered appropriate instruments for measuring the active range of motion in patients with non-specific neck pain in daily practice. Reliability is the aspect most frequently evaluated. Agreement, validity and responsiveness are documented less frequently.

Figures

Fig. 1
Fig. 1
Inclinometer
Fig. 2
Fig. 2
Cervical range of motion instrument

References

    1. Agarwal S, Allison GT, Singer KP. Reliability of the spin-T cervical goniometer in measuring cervical range of motion in an asymptomatic Indian population. J Manipulative Physiol Ther. 2005;28(7):487–492. doi: 10.1016/j.jmpt.2005.07.005.
    1. Agarwal S, Allison GT, Singer KP. Validation of the spin-T goniometer, a cervical range of motion device. J Manipulative Physiol Ther. 2005;28(8):604–609. doi: 10.1016/j.jmpt.2005.08.015.
    1. Alantara H, Hurri H, Heliovaara M, et al. Flexibility of the spine: normative values of goniometric and tape measurements. Scan J Rehabil Med. 1994;14:147–154.
    1. Alund M, Larsson SE. Three-dimensional analysis of neck motion; a clinical method. Spine. 1990;15:87–91. doi: 10.1097/00007632-199002000-00007.
    1. Amiri M, Jull G, Bullock-Saxton J. Measuring range of active cervical rotation in a position of full head flexion using the 3D Fastrak measurement system: an intra-tester reliability study. Man Ther. 2003;8(3):176–179. doi: 10.1016/S1356-689X(03)00009-2.
    1. Antonaci F, Bulgheroni M, Ghirmai S, Lanfranchi S, Dalla Toffola E, Sandrini G, Nappi G. 3D kinematic analysis and clinical evaluation of neck movements in patients with whiplash injury. Cephalalgia. 2002;22(7):533–542. doi: 10.1046/j.1468-2982.2002.00405.x.
    1. Assink N, Bergman GJ, Knoester B, Winters JC, Dijkstra PU, Postema K. Interobserver reliability of neck-mobility measurement by means of the flock-of-birds electromagnetic tracking system. J Manipulative Physiol Ther. 2005;28(6):408–413. doi: 10.1016/j.jmpt.2005.06.009.
    1. Balogun JA, Abereoje OK, Olaogun MO, Obajuluwa VA. Inter and intratester reliability of measuring neck motions with tape measure and Myrin gravity-reference goniometer. J Orthop Sports Phys Ther. 1989;10:248–253.
    1. Bergman GJ, Knoester B, Assink N, Dijkstra PU, Winters JC. Variation in the cervical range of motion over time measured by the “flock of birds” electromagnetic tracking system. Spine. 2005;30(6):650–654. doi: 10.1097/01.brs.0000155414.03723.3d.
    1. Bogduk N. Neck pain. Aust Fam Physician. 1984;13(1):26–30.
    1. Bot SD, Terwee CB, van der Windt DA, Bouter LM, Dekker J, de Vet HC. Clinimetric evaluation of shoulder disability questionnaires: a systematic review of the literature. Ann Rheum Dis. 2004;63(4):335–341. doi: 10.1136/ard.2003.007724.
    1. Bot SD, van der Waal JM, Terwee CB, van der Windt DA, Schellevis FG, Bouter LM, Dekker J. Incidence and prevalence of complaints of the neck and upper extremity in general practice. Ann Rheum Dis. 2005;64(1):118–123. doi: 10.1136/ard.2003.019349.
    1. Bruton A, Conway JH, Holgate ST. Reliability: What is it, and how is it measured? Physiotherapy. 2000;86:94–99. doi: 10.1016/S0031-9406(05)61211-4.
    1. Bulgheroni MV, Antonaci F, Ghirmai S, Sandrini G, Nappi G, Pedotti A. A 3D kinematic method for evaluating voluntary movements of the cervical spine in humans. Funct Neurol. 1998;13(3):239–245.
    1. Bush KW, Collins N, Portman L, Tillet N. Validity and intertester reliability of cervical range of motion using inclinometer measurements. J Man Manipulative Ther. 2000;8(2):52–61.
    1. Capuano-Pucci D, Rheault W, Aukai J, Bracke M, Day R, Patrick M. Intratester and intertester reliability of cervical range of motion device. Arch Phys Med Rehabil. 1991;18:338–340.
    1. Chiu TT, Sing KL. Evaluation of cervical range of motion and isometric neck muscle strength: reliability and validity. Clin Rehabil. 2002;16(8):851–858. doi: 10.1191/0269215502cr550oa.
    1. Christensen HW, Nilsson N. Natural variation of cervical range of motion: a one-way repeated-measures design. J Manipulative Physiol Ther. 1998;21(6):383–387.
    1. Christensen HW, Nilsson N. The reliability of measuring active and passive cervical range of motion: an observer-blinded and randomized repeated-measures design. J Manipulative Physiol Ther. 1998;21(5):341–347.
    1. Cleland JA, Childs JD, Fritz JM, Whitman JM. Interrater reliability of the history and physical examination in patients with mechanical neck pain. Arch Phys Med Rehabil. 2006;87(10):1388–1395. doi: 10.1016/j.apmr.2006.06.011.
    1. de Vet HC, Terwee CB, Knol DL, Bouter LM. When to use agreement versus reliability measures. J Clin Epidemiol. 2006;59(10):1033–1039. doi: 10.1016/j.jclinepi.2005.10.015.
    1. Dvir Z, Gal-Eshel N, Shamir B, Prushansky T, Pevzner E, Peretz C. Cervical motion in patients with chronic disorders of the cervical spine: a reproducibility study. Spine. 2006;31(13):E394–E399. doi: 10.1097/01.brs.0000219951.79922.df.
    1. Dvir Z, Prushansky T. Reproducibility and instrument validity of a new ultrasonography-based system for measuring cervical spine kinematics. Clin Biomech (Bristol, Avon) 2000;15(9):658–664. doi: 10.1016/S0268-0033(00)00033-4.
    1. Dvorak J, Antinnes JA, Panjabi M, Loustalot D, Bonomo M. Age and gender related normal motion of the cervical spine. Spine. 1992;17(10 Suppl):S393–S398. doi: 10.1097/00007632-199210001-00009.
    1. Dvorak J, Panjabi MM, Grob D, Novotny JE, Antinnes JA. Clinical validation of functional flexion/extension radiographs of the cervical spine. Spine. 1993;18(1):120–127. doi: 10.1097/00007632-199301000-00018.
    1. Eechaute C, Vaes P, Van Aerschot L, Asman S, Duquet W. The clinimetric qualities of patient-assessed instruments for measuring chronic ankle instability: a systematic review. BMC Musculoskelet Disord. 2007;8:6. doi: 10.1186/1471-2474-8-6.
    1. Fejer R, Kyvik KO, Hartvigsen J. The prevalence of neck pain in the world population: a systematic critical review of the literature. Eur Spine J. 2006;15(6):834–848. doi: 10.1007/s00586-004-0864-4.
    1. Ferrario VF, Sforza C, Serrao G, Grassi G, Mossi E. Active range of motion of the head and cervical spine: a three-dimensional investigation in healthy young adults. J Orthop Res. 2002;20(1):122–129. doi: 10.1016/S0736-0266(01)00079-1.
    1. Fitzpatrick R, Davey C, Buxton MJ, Jones DR. Evaluating patient-based outcome measures for use in clinical trials. Health Technol Assess. 1998;2(14):i–iv.
    1. Frobin W, Leivseth G, Biggemann M, Brinckmann P. Sagittal plane segmental motion of the cervical spine. A new precision measurement protocol and normal motion data of healthy adults. Clin Biomech (Bristol, Avon) 2002;17(1):21–31. doi: 10.1016/S0268-0033(01)00105-X.
    1. Haas M. Statistical methodology for reliability studies. J Manipulative Physiol Ther. 1991;14(2):119–132.
    1. Haynes MJ, Edmondston S. Accuracy and reliability of a new, protractor-based neck goniometer. J Manipulative Physiol Ther. 2002;25(9):579–586. doi: 10.1067/mmt.2002.128370.
    1. Hole DE, Cook JM, Bolton JE. Reliability and concurrent validity of two instruments for measuring cervical range of motion: effects of age and gender. Man Ther. 1995;1(1):36–42. doi: 10.1054/math.1995.0248.
    1. Hoppenbrouwers M, Eckhardt MM, Verkerk K, Verhagen A. Reproducibility of the measurement of active and passive cervical range of motion. J Manipulative Physiol Ther. 2006;29(5):363–367. doi: 10.1016/j.jmpt.2006.04.007.
    1. Hoving JL, Pool JJ, van Mameren H, Deville WJ, Assendelft WJ, de Vet HC, de Winter AF, Koes BW, Bouter LM. Reproducibility of cervical range of motion in patients with neck pain. BMC Musculoskelet Disord. 2005;6:59. doi: 10.1186/1471-2474-6-59.
    1. Hsieh CY, Yeung BW. Active neck motion measurements with a tape measure. J Orthop Sports Phys Ther. 1986;8:88–92.
    1. Jenkinson TR, Mallorie PA, Whitelock HC, Kennedy LG, Garrett SL, Calin A. Defining spinal mobility in ankylosing spondylitis (AS). The Bath AS Metrology Index. J Rheumatol. 1994;21(9):1694–1698.
    1. Jordan K. Assessment of published reliability studies for cervical spine range-of-motion measurement tools. J Manipulative Physiol Ther. 2000;23(3):180–195. doi: 10.1016/S0161-4754(00)90248-3.
    1. Jordan K, Dziedzic K, Jones PW, Ong BN, Dawes PT. The reliability of the three-dimensional FASTRAK measurement system in measuring cervical spine and shoulder range of motion in healthy subjects. Rheumatology (Oxford) 2000;39(4):382–388. doi: 10.1093/rheumatology/39.4.382.
    1. Jordan K, Haywood KL, Dziedzic K. Assessment of the 3-dimensional Fastrak measurement system in measuring range of motion in ankylosing spondylitis. J Rheumatol. 2004;31(11):2207–2215.
    1. Kadir N, Grayson MF, Goldberg AA, Swain MC. A new goniometer. Rheumatol Rehabil. 1981;20(4):219–226. doi: 10.1093/rheumatology/20.4.219.
    1. Koerhuis CL, Winters JC, van der Helm FC, Hof AL. Neck mobility measurement by means of the ‘Flock of Birds’ electromagnetic tracking system. Clin Biomech (Bristol, Avon) 2003;18(1):14–18. doi: 10.1016/S0268-0033(02)00146-8.
    1. Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics. 1977;33(1):159–174. doi: 10.2307/2529310.
    1. Lantz CA, Chen J, Buch D. Clinical validity and stability of active and passive cervical range of motion with regard to total and unilateral uniplanar motion. Spine. 1999;24(11):1082–1089. doi: 10.1097/00007632-199906010-00007.
    1. Lantz CA, Klein G, Chen J, Mannion A, Solinger AB, Dvorak J. A reassessment of normal cervical range of motion. Spine. 2003;28(12):1249–1257. doi: 10.1097/00007632-200306150-00007.
    1. Lohr KN, Aaronson NK, Alonso J, Burnam MA, Patrick DL, Perrin EB, Roberts JS. Evaluating quality-of-life and health status instruments: development of scientific review criteria. Clin Ther. 1996;18(5):979–992. doi: 10.1016/S0149-2918(96)80054-3.
    1. Love S, Gringmuth RH, Kazemi M, Cornacchia P, Schmolke M. Interexaminer and intraexaminer reliability of cervical passive range of motion using the CROM and Cybex 320 EDI. J Can Chiropract Assoc. 1998;42(4):222–228.
    1. Maksymowich Mallon WP C, Richardson R, Conner-Spady B, Jauregui E, Chung C, Zappala L, Pile K, Russell AS. Development and validation of a simple tape-based measurement tool for recording cervical rotation in patients with ankylosing spondylitis: comparison with a goniometer-based approach. J Rheumatol. 2006;33(11):2242–2249.
    1. Malmstrom EM, Karlberg M, Melander A, Magnusson M. Zebris versus Myrin: a comparative study between a three-dimensional ultrasound movement analysis and an inclinometer/compass method: intradevice reliability, concurrent validity, intertester comparison, intratester reliability, and intraindividual variability. Spine. 2003;28(21):E433–E440. doi: 10.1097/01.BRS.0000090840.45802.D4.
    1. Mannion AF, Klein GN, Dvorak J, Lanz C. Range of global motion of the cervical spine: intraindividual reliability and the influence of measurement device. Eur Spine J. 2000;9(5):379–385. doi: 10.1007/s005860000187.
    1. Moffett JAK, Hughes I, Griffiths P. Measurement of cervical spine movements using a simple inclinometer. Physiotherapy. 1989;19:302–305.
    1. Morphett AL, Crawford CM, Lee D. The use of electromagnetic tracking technology for measurement of passive cervical range of motion: a pilot study. J Manipulative Physiol Ther. 2003;26(3):152–159. doi: 10.1016/S0161-4754(02)54107-5.
    1. O’Driscoll SL, Tomenson J. The cervical spine. Clin Rheum Dis. 1982;8(3):617–630.
    1. Olson SL, O’Connor DP, Birmingham G, Broman P, Herrera L. Tender point sensitivity, range of motion, and perceived disability in subjects with neck pain. J Orthop Sports Phys Ther. 2000;30(1):13–20.
    1. Ordway NR, Seymour R, Donelson RG, Hojnowski L, Lee E, Edwards WT. Cervical sagittal range-of-motion analysis using three methods. Cervical range-of-motion device, 3space, and radiography. Spine. 1997;22(5):501–508. doi: 10.1097/00007632-199703010-00007.
    1. Pellechia GL, Bohannon RW. Active lateral flexion range of motion measurements obtained with a modified goniometer, reliability and estimates of normal. J Manipulative Physiol Ther. 1998;21:443–447.
    1. Peollson A, Hedlund R, Ertzgaard S, Oberg B. Intra- and intertester reliability and range of motion of the neck. Physiother Can. 2000;52(3):233–242.
    1. Petersen CM, Johnson RD, Schuit D. Reliability of cervical range of motion using the OSI CA 6000 spine motion analyser on asymptomatic and symptomatic subjects. Man Ther. 2000;5(2):82–88. doi: 10.1054/math.2000.0232.
    1. Piva SR, Erhard RE, Childs JD, Browder DA. Inter-tester reliability of passive intervertebral and active movements of the cervical spine. Man Ther. 2006;11(4):321–330. doi: 10.1016/j.math.2005.09.001.
    1. Pringle RK. Intra-instrument reliability of 4 goniometers. J Chiropract Med. 2003;3(2):91–95. doi: 10.1016/S0899-3467(07)60051-2.
    1. Rheault W, Albright B, Byers C, Franta M, Johnson A, Skowronek M. Intertester reliability of the cervical range of motion device. J Orthop Sports Phys Ther. 1992;15(3):147–150.
    1. Seffinger MA, Najm WI, Mishra SI, Adams A, Dickerson VM, Murphy LS, Reinsch S. Reliability of spinal palpation for diagnosis of back and neck pain: a systematic review of the literature. Spine. 2004;29(19):E413–E425. doi: 10.1097/01.brs.0000141178.98157.8e.
    1. Solinger AB, Chen J, Lantz CA. Standardized initial head position in cervical range-of-motion assessment: reliability and error analysis. J Manipulative Physiol Ther. 2000;23(1):20–26. doi: 10.1016/S0161-4754(00)90109-X.
    1. Stochkendahl MJ, Christensen HW, Hartvigsen J, Vach W, Haas M, Hestbaek L, Adams A, Bronfort G. Manual examination of the spine: a systematic critical literature review of reproducibility. J Manipulative Physiol Ther. 2006;29(6):475–485. doi: 10.1016/j.jmpt.2006.06.011.
    1. Strimpakos N, Sakellari V, Gioftsos G, Papathanasiou M, Brountzos E, Kelekis D, Kapreli E, Oldham J. Cervical spine ROM measurements: optimizing the testing protocol by using a 3D ultrasound-based motion analysis system. Cephalalgia. 2005;25(12):1133–1145. doi: 10.1111/j.1468-2982.2005.00970.x.
    1. Swinkels RA, Bouter LM, Oostendorp RA, van den Ende CH. Impairment measures in rheumatic disorders for rehabilitation medicine and allied health care: a systematic review. Rheumatol Int. 2005;25(7):501–512. doi: 10.1007/s00296-005-0603-0.
    1. Terwee CB, Bot SD, de Boer MR, van der Windt DA, Knol DL, Dekker J, Bouter LM, de Vet HC. Quality criteria were proposed for measurement properties of health status questionnaires. J Clin Epidemiol. 2007;60(1):34–42. doi: 10.1016/j.jclinepi.2006.03.012.
    1. Tousignant M, Boucher N, Bourbonnais J, Gravelle T, Quesnel M, Brosseau L. Intratester and intertester reliability of the Cybex electronic digital inclinometer (EDI-320) for measurement of active neck flexion and extension in healthy subjects. Man Ther. 2001;6(4):235–241. doi: 10.1054/math.2001.0419.
    1. Tousignant M, de Bellefeuille L, O’Donoughue S, Grahovac S. Criterion validity of the cervical range of motion (CROM) goniometer for cervical flexion and extension. Spine. 2000;25(3):324–330. doi: 10.1097/00007632-200002010-00011.
    1. Tousignant M, Duclos E, Lafleche S, Mayer A, Tousignant-Laflamme Y, Brosseau L, O’Sullivan JP. Validity study for the cervical range of motion device used for lateral flexion in patients with neck pain. Spine. 2002;27(8):812–817. doi: 10.1097/00007632-200204150-00007.
    1. Tousignant M, Smeesters C, Breton AM, Breton E, Corriveau H. Criterion validity study of the cervical range of motion (CROM) device for rotational range of motion on healthy adults. J Orthop Sports Phys Ther. 2006;36(4):242–248.
    1. Trott PH, Pearcy MJ, Ruston SA, Fulton I, Brien C. Three-dimensional analysis of active cervical motion: the effect of age and gender. Clin Biomech (Bristol, Avon) 1996;11(4):201–206. doi: 10.1016/0268-0033(95)00072-0.
    1. Tucci SM, Hicks JE, Gross EG, Campbell W, Danoff J. Cervical motion assessment: a new, simple and accurate method. Arch Phys Med Rehabil. 1986;67(4):225–230.
    1. Van Genderen FR, de Bie RA, Helders PJM, van Meeteren NLU. Reliability research: towards a more clinically relevant approach. Phys Ther Rev. 2003;8:169–176. doi: 10.1179/108331903225003172.
    1. van Trijffel E, Anderegg Q, Bossuyt PM, Lucas C. Inter-examiner reliability of passive assessment of intervertebral motion in the cervical and lumbar spine: a systematic review. Man Ther. 2005;10(4):256–269. doi: 10.1016/j.math.2005.04.008.
    1. Veenhof C, Bijlsma JW, van den Ende CH, van Dijk GM, Pisters MF, Dekker J. Psychometric evaluation of osteoarthritis questionnaires: a systematic review of the literature. Arthritis Rheum. 2006;55(3):480–492. doi: 10.1002/art.22001.
    1. Viikari-Juntura E. Interexaminer reliability of observations in physical examinations of the neck. Phys Ther. 1987;67(10):1526–1532.
    1. Viitanen JV, Kokko ML, Heikkila S, Kautiainen H. Neck mobility assessment in ankylosing spondylitis: a clinical study of nine measurements including new tape methods for cervical rotation and lateral flexion. Br J Rheumatol. 1998;37(4):377–381. doi: 10.1093/rheumatology/37.4.377.
    1. Vos C, Verhagen A, Passchier J, Koes B. Management of acute neck pain in general practice: a prospective study. Br J Gen Pract. 2007;57(534):23–28.
    1. Wainner RS, Fritz JM, Irrgang JJ, Boninger ML, Delitto A, Allison S. Reliability and diagnostic accuracy of the clinical examination and patient self-report measures for cervical radiculopathy. Spine. 2003;28(1):52–62. doi: 10.1097/00007632-200301010-00014.
    1. Wang SF, Teng CC, Lin KH. Measurement of cervical range of motion pattern during cyclic neck movement by an ultrasound-based motion system. Man Ther. 2005;10(1):68–72. doi: 10.1016/j.math.2004.08.009.
    1. Wolfenberger VA, Bui Q, Batenchuk GB. A comparison of methods of evaluating cervical range of motion. J Manipulative Physiol Ther. 2002;25(3):154–160. doi: 10.1067/mmt.2002.122327.
    1. Wu SK, Lan HH, Kuo LC, Tsai SW, Chen CL, Su FC. The feasibility of a video-based motion analysis system in measuring the segmental movements between upper and lower cervical spine. Gait Posture. 2007;26(1):161–166. doi: 10.1016/j.gaitpost.2006.07.016.
    1. Youdas JW, Carey JR, Garrett TR. Reliability of measurements of cervical spine range of motion–comparison of three methods. Phys Ther. 1991;71(2):98–104.
    1. Youdas JW, Garrett TR, Suman VJ, Bogard CL, Hallman HO, Carey JR. Normal range of motion of the cervical spine: an initial goniometric study. Phys Ther. 1992;72(11):770–780.
    1. Zachman ZJ, Traina AD, Keating JC, Bolles ST, Braun-Porter L. Interexaminer reliability and concurrent validity for the measurement of cervical ranges of motion. J Manipulative Physiol Ther. 1989;12:205–210.

Source: PubMed

3
Abonnieren