Influence of Implant Position on Stress Distribution in Implant-Assisted Distal Extension Removable Partial Dentures: A 3D Finite Element Analysis

Yeganeh Memari, Allahyar Geramy, Amir Fayaz, Shirin Rezvani Habib Abadi, Yasaman Mansouri, Yeganeh Memari, Allahyar Geramy, Amir Fayaz, Shirin Rezvani Habib Abadi, Yasaman Mansouri

Abstract

Objective: Distal extension removable partial denture is a prosthesis with lack of distal dental support with a 13-fold difference in resiliency between the mucosa and the periodontal ligament, resulting in leverage during compression forces. It may be potentially destructive to the abutments and the surrounding tissues. The aim of this study was to assess the effect of implant location on stress distribution, in distal extension implant assisted removable partial dentures.

Materials and methods: Three-dimensional models of a bilateral distal extension partially edentulous mandible containing anterior teeth and first premolar in both sides of the arch, a partial removable denture and an implant (4×10mm) were designed. With the aid of the finite element program ANSYS 8.0, the models were meshed and strictly vertical forces of 10 N were applied to each cusp tip. Displacement and von Mises Maps were plotted for visualization of results.

Results: When an implant was placed in the second premolar region, the highest stress on implant, abutment tooth and cancellous bone was shown. The lowest stress was shown on implant and bone in the 1(st) molar area.

Conclusion: Implants located in the first molar area showed the least distribution of stresses in the analyzed models.

Keywords: Finite Element Analysis; Implant; Removable partial denture.

Figures

Fig 1.
Fig 1.
Model A, Model B and Model C.
Fig 2.
Fig 2.
The meshed model
Fig 3.
Fig 3.
Assessment of 10 points for stress probing in the residual soft tissue ridge.
Fig 4.
Fig 4.
Stress contours when the implant was in the second premolar area.
Fig 5.
Fig 5.
Stress contours when the implant was in the first molar area.
Fig 6.
Fig 6.
Stress contours when the implant was in the second molar location.

References

    1. Cunha LD, Pellizzer EP, Verri FR, Pereira JA. Evaluation of the influence of location of osseointegrated implants associated with mandibular removable partial dentures. Implant Dent. 2008 Sep;17(3):278–87. doi: 10.1097/ID.0b013e31818363b2.
    1. Tebrock OC, Rohen RM, Fenster RK, Pelleu GB., Jr The effect of various clasping systems on the mobility of abutment teeth for distal-extension removable partial dentures. J Prosthet Dent. 1979 May;41(5):511–6.
    1. Craig RG, Farah JW. Stresses from loading distal-extension removable partial dentures. J Prosthet Dent. 1978 Mar;39(3):274–7.
    1. Branemark PI. Osseointegration and its experimental background. J Prosthet Dent. 1983 Sep;50(3):399–410.
    1. Keltjens HM, Kayser AF, Hertel R, Battistuzzi PG. Distal extension removable partial dentures supported by implants and residual teeth: considerations and case reports. Int J Oral Maxillofac Implants. 1993;8(2):208–13.
    1. Cordioli G, Majzoub Z, Castagna S. Mandibular over dentures anchored to single implants: a five-year prospective study. J Prosthet Dent. 1997 Aug;78(2):159–65.
    1. Maeda Y, Sogo M, Tsutsumi S. Efficacy of a posterior implant support for extra shortened dental arches: a biomechanical model analysis. J Oral Rehabil. 2005 Sep;32(9):656–60.
    1. Wright KW, Yettram AL. Reactive force distributions for teeth when loaded singly and when used as fixed partial denture abutments. J Prosthet Dent. 1979 Oct;42(4):411–6.
    1. Atmaram GH, Mohammed H. Estimation of physiologic stresses with a nature tooth considering fibrous PDL structure. J Dent Res. 1981 May;60(5):873–7.
    1. Geramy A, Faghihi SH. Secondary trauma from occlusion: 3D analysis using Finite Element method. Quintessence Int. 2004 Nov-Dec;35(10):835–43.
    1. Silva M, Consani R. Association between implants and removable partial dentures: review of the literature. RSBO. 2011 Jan-Mar;8(1):97–101.
    1. Verri FR, Pellizzer EP, Rocha EP, Pereira JA. Influence of length and diameter of implants Influence of length and diameter of implants associated with distal extension removable partial dentures. Implant Dent. 2007 Sep;16(3):270–80.
    1. Kordatzis K, Wright PS, Meijer HJ. Posterior Mandibular Residual Ridge Resorption in Patients with Conventional Dentures and Implant Overdentures. Int J Oral Maxillofac Implants. 2003 May-Jun;18(3):447–52.
    1. Kuzmanovic DV, Payne AG, Purton DG. Distal implants to modify the Kennedy classification of a removable partial denture: a clinical report. J Prosthet Dent. 2004 Jul;92(1):8–11.
    1. Mitrani R, Brudvik JS, Phillips KM. Posterior implants for distal extension removable prostheses: a retrospective study. Int J Periodontics Restorative Dent. 2003 Aug;23(4):353–9.
    1. Kapur KK. Veterans Administration cooperative dental implant study–Comparison between fixed partial dentures supported by blade-vent implants and removable partial dentures. Part III: Comparison between two treatment modalities. J Prosthet Dent. 1991;62:272–283.
    1. Ben-Ur Z, Aviv I, Maharshak B. Factors affecting displacement of free-end saddle removable partial dentures. Quintessence Int. 1991 Jan;22(1):23–7.
    1. Kelly E. Changes caused by a mandibular removable partial denture opposing a mandibular complete denture. J Prosthet Dent. 1972 Feb;27(2):140–50.
    1. Ohkubo C, Sato J, Hosoi T, Kurtz KS. O-ring attachments for transitional implant-retained overdentures. J Prosthet Dent. 2004 Feb;91(2):195–7.
    1. Ohkubo C, Kurihara D, Shimpo H, Suzuki Y, Kokubo Y, Hosoi T. Effect of implant support on distal extension removable partial dentures: in vitro assessment. J Oral Rehabil. 2007 Jan;34(1):52–6.
    1. Cunha LD, Pellizzer EP, Verri FR, Pereira JA. Evaluation of the influence of location of osseointegrated implants associated with mandibular removable partial dentures. Implant Dent. 2008 Sep;17(3):278–87. doi: 10.1097/ID.0b013e31818363b2.
    1. Amet EM. A unique method of combining teeth and endosseous implants for a stable removable prosthesis. J Oral Implantol. 1993;19(3):216–20.
    1. Grossmann Y, Nissan J, Levin L. Clinical effectiveness of implant-supported removable partial dentures: a review of the literature and retrospective case evaluation. J Oral Maxillofac Surg. 2009 Sep;67(9):1941–6. doi: 10.1016/j.joms.2009.04.081.

Source: PubMed

3
Abonnieren