Esta página se tradujo automáticamente y no se garantiza la precisión de la traducción. por favor refiérase a versión inglesa para un texto fuente.

A Clinical Trial of Proximal Composite Restorations (Automatrix)

19 de abril de 2017 actualizado por: Farhan Raza Khan, Aga Khan University
Several techniques have been advocated to get good contacts in dental composite restorations including interdental separation ring. The investigators study focuses on using separation ring with circumferential matrix band instead of a sectional band. Moreover, the investigators have attempted to study proximal tightness and proximal contours of composite restoration as separate variables

Descripción general del estudio

Descripción detallada

A total of 188 premolar teeth with proximal cavity to be assigned on alternate basis in two groups. Intervention group teeth received Automatrix band after cavity preparation followed by the separation ring using clamp while the control group received Automatrix band alone.

All teeth to be restored with P-60 composite restorative material(3M-ESPE Dental, USA). Outcome (proximal tightness) is determined by a blinded assessor just after the restoration.

Tipo de estudio

Intervencionista

Inscripción (Actual)

188

Fase

  • No aplica

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Ubicaciones de estudio

    • Sindh
      • Karachi, Sindh, Pakistán, 74800
        • Dental Clinics, Aga Khan University Hospital

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

18 años a 65 años (Adulto, Adulto Mayor)

Acepta Voluntarios Saludables

Sí

Géneros elegibles para el estudio

Todos

Descripción

Inclusion Criteria:

  • patients who had supra gingival Class II cavities in permanent premolars. Teeth with cavity isthmus less than one-third of intercuspal distance were inducted

Exclusion Criteria:

  • Partially erupted teeth, teeth with non-carious tooth surface wear or with orthodontic bands or brackets or whose adjacent tooth continuous with the cavity side is missing were excluded.

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Propósito principal: Tratamiento
  • Asignación: No aleatorizado
  • Modelo Intervencionista: Asignación paralela
  • Enmascaramiento: Único

Armas e Intervenciones

Grupo de participantes/brazo
Intervención / Tratamiento
Experimental: automatrix band, Separation ring
The prepared teeth received Automatrix band (similar to the control group, product code# 62422513). The Automatrix was burnished against the adjacent tooth gently. Anatomical wedges were applied in the proximal area and then the separation ring (BiTine® round ring by Palodent systems, Dentsply International, DE, USA product # 659040) placed with the help of retainer forceps.
Separation ring placed along with automatrix band
Otros nombres:
  • BiTine® Separation ring by Palodent, product # 659040)
band placed with a tightening device
Otros nombres:
  • circumferential automatrix band by Dentsply
Comparador activo: automatrix band
Teeth received Automatrix band alone (Wide-Regular type, dimensions 7.9 mm height and 0.05mm thickness, product code # 62422513). It was secured on the prepared tooth and burnished against the adjacent tooth gently. Anatomical wedges were placed in the inter-proximal area gingival to the cavity preparation.
band placed with a tightening device
Otros nombres:
  • circumferential automatrix band by Dentsply

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
proximal tightness
Periodo de tiempo: 1 day (just after dental restoration)
The tightness of the proximal contact area resulting from either of the two matrix band system. It was measured using a nine inch long nylon dental floss (Johnson and Johnson, USA).
1 day (just after dental restoration)

Medidas de resultado secundarias

Medida de resultado
Medida Descripción
Periodo de tiempo
proximal contours
Periodo de tiempo: 1 day (just after restoration placement)
To be examined clinically with an explorer and mouth mirror and then on the periapical radiograph by the blinded co investigator.
1 day (just after restoration placement)

Otras medidas de resultado

Medida de resultado
Medida Descripción
Periodo de tiempo
Overhang of the restoration
Periodo de tiempo: 1 day (just after the restoration placement)
To be examined clinically with an explorer and mouth mirror and then on the periapical radiograph by the blinded co investigator.
1 day (just after the restoration placement)

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Patrocinador

Investigadores

  • Investigador principal: Farhan R Khan, FCPS, AKU

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio

1 de noviembre de 2007

Finalización primaria (Actual)

1 de noviembre de 2011

Finalización del estudio (Actual)

1 de diciembre de 2011

Fechas de registro del estudio

Enviado por primera vez

8 de agosto de 2012

Primero enviado que cumplió con los criterios de control de calidad

9 de agosto de 2012

Publicado por primera vez (Estimar)

10 de agosto de 2012

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

20 de abril de 2017

Última actualización enviada que cumplió con los criterios de control de calidad

19 de abril de 2017

Última verificación

1 de abril de 2017

Más información

Términos relacionados con este estudio

Otros números de identificación del estudio

  • 640-Sur-ERC-06
  • 640-Sur/ERC-06 (Otro identificador: Aga khan University)

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .

Suscribir