Esta página se tradujo automáticamente y no se garantiza la precisión de la traducción. por favor refiérase a versión inglesa para un texto fuente.

Effect of Different Plasma Insulin Levels on the Accuracy of Continuous Subcutaneous Glucose Monitoring

New Strategies for Automated Glycaemic Control: the Issue of Continuous Glucose Monitoring Accuracy Under Hypoglycaemic Conditions

Achieving near-normoglycaemia has been established as the main objective for most patients with diabetes. However, it is well known that intensification of treatment is associated with an increase in the frequency of hypoglycemia, especially in the context of insulin therapy. The burden of hypoglycemia in terms of psychological implications, morbidity and even mortality, explains why it has been defined as the main limiting factor to achievement of good metabolic control.

Continuous subcutaneous glucose monitoring (CGM) devices have been claimed to be useful in hypoglycemia detection/prevention, allowing theoretically for safer intensification of therapy in diabetic patients. However, accuracy of CGM devices, especially in the hypoglycemic range, raises some concerns. In fact, commercially available CGM devices estimate plasma glucose from measurements in the interstitial fluid and not in plasma. However, the relationship between plasma and interstitial glucose is not fully understood, especially under dynamic conditions, and this may explain the poor CGM performance during rapid changes in blood glucose and hypoglycemia.

In this project, the relationship between plasma and interstitial glucose will be evaluated under conditions of normal glucose concentrations and hypoglycemia. Experiments will be performed to assess the role, if any, of different plasma insulin concentrations on the accuracy of CGM.

All the information obtained may be relevant to the improvement of the ability of CGM devices to detect hypoglycemia and hypoglycemic risk.

Descripción general del estudio

Tipo de estudio

Intervencionista

Inscripción (Actual)

14

Fase

  • No aplica

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Ubicaciones de estudio

      • Valencia, España, 46010
        • Servicio de Endocrinología y Nutrición, Hospital Clínico Universitario de Valencia

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

18 años a 60 años (Adulto)

Acepta Voluntarios Saludables

No

Géneros elegibles para el estudio

Todos

Descripción

Inclusion Criteria:

  • Subjects with type 1 diabetes mellitus meeting all of the following criteria will be considered for admission to the study:

    • Aged between 18 and 60 years
    • Under CSII or MDI treatment for at least six months before Visit 1
    • Body mass index of between 18 and 30 kg/m2
    • HbA1c 6.0-8.5% at Visit 1
    • Normal laboratory values, ECG, and vital signs unless the investigator considered an abnormality to be clinically irrelevant
    • Women postmenopausal or using contraception judged by the investigator to be adequate (e.g., oral contraceptives, intra-uterine device or surgical treatment)

Exclusion Criteria:

  • Subjects meeting any of the following criteria will not be included in the study:

    • Pregnancy and lactation
    • History of hypersensitivity to the study medications or to drugs with similar chemical structures
    • Confirmed hypoglycaemia unawareness
    • Progressive fatal diseases
    • History of drug or alcohol abuse
    • History of positive HIV or hepatitis B or C test
    • Impaired hepatic function, as shown by, but not limited to, SGPT or SGOT of more than twice the upper limit of the normal range at visit 1
    • Impaired renal function, as shown by, but not limited to, serum creatinine > 1.5 mg/dL at visit 1
    • Clinically relevant microvascular, cardiovascular, hepatic, neurologic, endocrine or other major systemic diseases other than T1DM which could hinder implementation of the clinical study protocol or interpretation of the study results
    • Pre-planned surgery during the study
    • Blood donation of more than 500 ml during the past three months for men, or during the past six months for women
    • Mental condition rendering the subject unable to understand the nature, scope and possible consequences of the study
    • Subject unlikely to comply with clinical study protocol, e.g., uncooperative attitude, inability to return for follow-up visits, or poor likelihood of completing the study
    • Receipt of an experimental drug or use of an experimental device during the past 30 days.

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Propósito principal: Ciencia básica
  • Asignación: Aleatorizado
  • Modelo Intervencionista: Asignación cruzada
  • Enmascaramiento: Doble

Armas e Intervenciones

Grupo de participantes/brazo
Intervención / Tratamiento
Otro: High plasma insulin-Low plasma insulin
Seven out of the 14 subjects recruited in the study have been randomized to receive on the first study day a High insulin glucose clamp and on the second day a Low insulin glucose clamp (sequence 'AB')
Primed intravenous insulin infusion at a rate of 1mU/kg/min is given during the whole study duration. Glucose is infused at a variable rate to maintain plasma glucose concentrations 'clamped' at pre-specified levels. Plasma glucose levels will be the same in both study arms.
Primed intravenous insulin infusion at a rate of 0.3mU/kg/min is given during the whole study duration. Glucose is infused at a variable rate to maintain plasma glucose concentrations 'clamped' at pre-specified levels. Plasma glucose levels will be the same in both study arms.
Otro: Low plasma insulin-High plasma insulin
Seven out of the 14 subjects recruited in the study have been randomized to receive on the first study day a Low insulin glucose clamp and on the second day a High insulin glucose clamp (sequence 'BA')
Primed intravenous insulin infusion at a rate of 1mU/kg/min is given during the whole study duration. Glucose is infused at a variable rate to maintain plasma glucose concentrations 'clamped' at pre-specified levels. Plasma glucose levels will be the same in both study arms.
Primed intravenous insulin infusion at a rate of 0.3mU/kg/min is given during the whole study duration. Glucose is infused at a variable rate to maintain plasma glucose concentrations 'clamped' at pre-specified levels. Plasma glucose levels will be the same in both study arms.

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Normalized current signal from the CGM devices
Periodo de tiempo: 330 minutes

CGM devices are electrochemical sensors. Currently available sensors are placed in the subcutaneous tissue where they react with the glucose of the interstitial fluid giving a current signal (in nano Amperes), which is proportional to glucose concentrations. The current signal is then filtered and transformed into plasma glucose estimations through a calibration algorithm built into the CGM device.

In this study we will analyze the current signal from CGM obtained under two different experimental conditions:

  1. Eu-hypoglycemic clamp with High plasma insulin concentrations
  2. Eu-hypoglycemic clamp with relatively Low plasma insulin concentrations

This will allow for establishing the role, if any, of different plasma insulin concentrations on the accuracy of CGM to identify plasma glucose falls resulting in hypoglycaemia.

Since CGM sensors can exhibit different sensitivities to glucose concentrations, the current signal will be normalized before statistical analysis

330 minutes

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Investigadores

  • Investigador principal: Francisco Javier Ampudia-Blasco, MD, PhD, Hospital Clínico Universitario de Valencia - Fundación INCLIVA

Publicaciones y enlaces útiles

La persona responsable de ingresar información sobre el estudio proporciona voluntariamente estas publicaciones. Estos pueden ser sobre cualquier cosa relacionada con el estudio.

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio

1 de octubre de 2011

Finalización primaria (Actual)

1 de septiembre de 2012

Finalización del estudio (Actual)

1 de octubre de 2012

Fechas de registro del estudio

Enviado por primera vez

24 de octubre de 2012

Primero enviado que cumplió con los criterios de control de calidad

24 de octubre de 2012

Publicado por primera vez (Estimar)

26 de octubre de 2012

Actualizaciones de registros de estudio

Última actualización publicada (Estimar)

26 de octubre de 2012

Última actualización enviada que cumplió con los criterios de control de calidad

24 de octubre de 2012

Última verificación

1 de octubre de 2012

Más información

Términos relacionados con este estudio

Otros números de identificación del estudio

  • FP7-PEOPLE-2009-IEF #252085-2
  • Spanish Ministry of Science (Otro número de subvención/financiamiento: spanish Ministry of Science, DPI2010-20764-C02-01)

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .

Suscribir