Ezt az oldalt automatikusan lefordították, és a fordítás pontossága nem garantált. Kérjük, olvassa el a angol verzió forrásszöveghez.

Effect of Different Plasma Insulin Levels on the Accuracy of Continuous Subcutaneous Glucose Monitoring

New Strategies for Automated Glycaemic Control: the Issue of Continuous Glucose Monitoring Accuracy Under Hypoglycaemic Conditions

Achieving near-normoglycaemia has been established as the main objective for most patients with diabetes. However, it is well known that intensification of treatment is associated with an increase in the frequency of hypoglycemia, especially in the context of insulin therapy. The burden of hypoglycemia in terms of psychological implications, morbidity and even mortality, explains why it has been defined as the main limiting factor to achievement of good metabolic control.

Continuous subcutaneous glucose monitoring (CGM) devices have been claimed to be useful in hypoglycemia detection/prevention, allowing theoretically for safer intensification of therapy in diabetic patients. However, accuracy of CGM devices, especially in the hypoglycemic range, raises some concerns. In fact, commercially available CGM devices estimate plasma glucose from measurements in the interstitial fluid and not in plasma. However, the relationship between plasma and interstitial glucose is not fully understood, especially under dynamic conditions, and this may explain the poor CGM performance during rapid changes in blood glucose and hypoglycemia.

In this project, the relationship between plasma and interstitial glucose will be evaluated under conditions of normal glucose concentrations and hypoglycemia. Experiments will be performed to assess the role, if any, of different plasma insulin concentrations on the accuracy of CGM.

All the information obtained may be relevant to the improvement of the ability of CGM devices to detect hypoglycemia and hypoglycemic risk.

A tanulmány áttekintése

Tanulmány típusa

Beavatkozó

Beiratkozás (Tényleges)

14

Fázis

  • Nem alkalmazható

Kapcsolatok és helyek

Ez a rész a vizsgálatot végzők elérhetőségeit, valamint a vizsgálat lefolytatásának helyére vonatkozó információkat tartalmazza.

Tanulmányi helyek

      • Valencia, Spanyolország, 46010
        • Servicio de Endocrinología y Nutrición, Hospital Clínico Universitario de Valencia

Részvételi kritériumok

A kutatók olyan embereket keresnek, akik megfelelnek egy bizonyos leírásnak, az úgynevezett jogosultsági kritériumoknak. Néhány példa ezekre a kritériumokra a személy általános egészségi állapota vagy a korábbi kezelések.

Jogosultsági kritériumok

Tanulmányozható életkorok

18 év (Felnőtt)

Egészséges önkénteseket fogad

Nem

Tanulmányozható nemek

Összes

Leírás

Inclusion Criteria:

  • Subjects with type 1 diabetes mellitus meeting all of the following criteria will be considered for admission to the study:

    • Aged between 18 and 60 years
    • Under CSII or MDI treatment for at least six months before Visit 1
    • Body mass index of between 18 and 30 kg/m2
    • HbA1c 6.0-8.5% at Visit 1
    • Normal laboratory values, ECG, and vital signs unless the investigator considered an abnormality to be clinically irrelevant
    • Women postmenopausal or using contraception judged by the investigator to be adequate (e.g., oral contraceptives, intra-uterine device or surgical treatment)

Exclusion Criteria:

  • Subjects meeting any of the following criteria will not be included in the study:

    • Pregnancy and lactation
    • History of hypersensitivity to the study medications or to drugs with similar chemical structures
    • Confirmed hypoglycaemia unawareness
    • Progressive fatal diseases
    • History of drug or alcohol abuse
    • History of positive HIV or hepatitis B or C test
    • Impaired hepatic function, as shown by, but not limited to, SGPT or SGOT of more than twice the upper limit of the normal range at visit 1
    • Impaired renal function, as shown by, but not limited to, serum creatinine > 1.5 mg/dL at visit 1
    • Clinically relevant microvascular, cardiovascular, hepatic, neurologic, endocrine or other major systemic diseases other than T1DM which could hinder implementation of the clinical study protocol or interpretation of the study results
    • Pre-planned surgery during the study
    • Blood donation of more than 500 ml during the past three months for men, or during the past six months for women
    • Mental condition rendering the subject unable to understand the nature, scope and possible consequences of the study
    • Subject unlikely to comply with clinical study protocol, e.g., uncooperative attitude, inability to return for follow-up visits, or poor likelihood of completing the study
    • Receipt of an experimental drug or use of an experimental device during the past 30 days.

Tanulási terv

Ez a rész a vizsgálati terv részleteit tartalmazza, beleértve a vizsgálat megtervezését és a vizsgálat mérését.

Hogyan készül a tanulmány?

Tervezési részletek

  • Elsődleges cél: Alapvető tudomány
  • Kiosztás: Véletlenszerűsített
  • Beavatkozó modell: Crossover kiosztás
  • Maszkolás: Kettős

Fegyverek és beavatkozások

Résztvevő csoport / kar
Beavatkozás / kezelés
Egyéb: High plasma insulin-Low plasma insulin
Seven out of the 14 subjects recruited in the study have been randomized to receive on the first study day a High insulin glucose clamp and on the second day a Low insulin glucose clamp (sequence 'AB')
Primed intravenous insulin infusion at a rate of 1mU/kg/min is given during the whole study duration. Glucose is infused at a variable rate to maintain plasma glucose concentrations 'clamped' at pre-specified levels. Plasma glucose levels will be the same in both study arms.
Primed intravenous insulin infusion at a rate of 0.3mU/kg/min is given during the whole study duration. Glucose is infused at a variable rate to maintain plasma glucose concentrations 'clamped' at pre-specified levels. Plasma glucose levels will be the same in both study arms.
Egyéb: Low plasma insulin-High plasma insulin
Seven out of the 14 subjects recruited in the study have been randomized to receive on the first study day a Low insulin glucose clamp and on the second day a High insulin glucose clamp (sequence 'BA')
Primed intravenous insulin infusion at a rate of 1mU/kg/min is given during the whole study duration. Glucose is infused at a variable rate to maintain plasma glucose concentrations 'clamped' at pre-specified levels. Plasma glucose levels will be the same in both study arms.
Primed intravenous insulin infusion at a rate of 0.3mU/kg/min is given during the whole study duration. Glucose is infused at a variable rate to maintain plasma glucose concentrations 'clamped' at pre-specified levels. Plasma glucose levels will be the same in both study arms.

Mit mér a tanulmány?

Elsődleges eredményintézkedések

Eredménymérő
Intézkedés leírása
Időkeret
Normalized current signal from the CGM devices
Időkeret: 330 minutes

CGM devices are electrochemical sensors. Currently available sensors are placed in the subcutaneous tissue where they react with the glucose of the interstitial fluid giving a current signal (in nano Amperes), which is proportional to glucose concentrations. The current signal is then filtered and transformed into plasma glucose estimations through a calibration algorithm built into the CGM device.

In this study we will analyze the current signal from CGM obtained under two different experimental conditions:

  1. Eu-hypoglycemic clamp with High plasma insulin concentrations
  2. Eu-hypoglycemic clamp with relatively Low plasma insulin concentrations

This will allow for establishing the role, if any, of different plasma insulin concentrations on the accuracy of CGM to identify plasma glucose falls resulting in hypoglycaemia.

Since CGM sensors can exhibit different sensitivities to glucose concentrations, the current signal will be normalized before statistical analysis

330 minutes

Együttműködők és nyomozók

Itt találhatja meg a tanulmányban érintett személyeket és szervezeteket.

Nyomozók

  • Kutatásvezető: Francisco Javier Ampudia-Blasco, MD, PhD, Hospital Clínico Universitario de Valencia - Fundación INCLIVA

Publikációk és hasznos linkek

A vizsgálattal kapcsolatos információk beviteléért felelős személy önkéntesen bocsátja rendelkezésre ezeket a kiadványokat. Ezek bármiről szólhatnak, ami a tanulmányhoz kapcsolódik.

Tanulmányi rekorddátumok

Ezek a dátumok nyomon követik a ClinicalTrials.gov webhelyre benyújtott vizsgálati rekordok és összefoglaló eredmények benyújtásának folyamatát. A vizsgálati feljegyzéseket és a jelentett eredményeket a Nemzeti Orvostudományi Könyvtár (NLM) felülvizsgálja, hogy megbizonyosodjon arról, hogy megfelelnek-e az adott minőség-ellenőrzési szabványoknak, mielőtt közzéteszik őket a nyilvános weboldalon.

Tanulmány főbb dátumok

Tanulmány kezdete

2011. október 1.

Elsődleges befejezés (Tényleges)

2012. szeptember 1.

A tanulmány befejezése (Tényleges)

2012. október 1.

Tanulmányi regisztráció dátumai

Először benyújtva

2012. október 24.

Először nyújtották be, amely megfelel a minőségbiztosítási kritériumoknak

2012. október 24.

Első közzététel (Becslés)

2012. október 26.

Tanulmányi rekordok frissítései

Utolsó frissítés közzétéve (Becslés)

2012. október 26.

Az utolsó frissítés elküldve, amely megfelel a minőségbiztosítási kritériumoknak

2012. október 24.

Utolsó ellenőrzés

2012. október 1.

Több információ

A tanulmányhoz kapcsolódó kifejezések

Egyéb vizsgálati azonosító számok

  • FP7-PEOPLE-2009-IEF #252085-2
  • Spanish Ministry of Science (Egyéb támogatási/finanszírozási szám: spanish Ministry of Science, DPI2010-20764-C02-01)

Ezt az információt közvetlenül a clinicaltrials.gov webhelyről szereztük be, változtatás nélkül. Ha bármilyen kérése van vizsgálati adatainak módosítására, eltávolítására vagy frissítésére, kérjük, írjon a következő címre: register@clinicaltrials.gov. Amint a változás bevezetésre kerül a clinicaltrials.gov oldalon, ez a webhelyünkön is automatikusan frissül. .

3
Iratkozz fel