- ICH GCP
- Registro de ensayos clínicos de EE. UU.
- Ensayo clínico NCT02780947
Prophylactic Substrate Ablation in Post-myocardial Patients Undergoing Defibrillator Implantation.
Descripción general del estudio
Estado
Intervención / Tratamiento
Descripción detallada
Background In patients with Ventricular Tachycardia (VT) and structural heart disease, the Implanted Cardioverter Defibrillator (ICD), provides a significant protection against the risk of sudden death, however it does not prevent arrhythmia recurrences [1-7]. ICD therapies, especially shocks, pose several risks, including decreased quality of life, increased mortality among patients who suffer ICD shock compared with patients who do not and clinically significant anxiety and depression as a result of recurrent ICD shocks, which has been found to occur in more than 50% of patients [8-12]. Furthermore, ICD implantation has been found not to protect against sudden cardiac death in 3-7% of patients [13].
The benefit of novel ICD programming in reducing inappropriate ICD therapy and mortality was demonstrated in Multicenter Automatic Defibrillator Implantation Trial-Reduce Inappropriate Therapy (MADIT-RIT) [14]. Catheter ablation has been considered a plausible curative therapy for VT prevention, especially in patients with VT episodes [15]. The Substrate Mapping and Ablation in Sinus Rhythm to Halt Ventricular Tachycardia (SMASH-VT) and the Ventricular Tachycardia Ablation in Coronary Heart Disease (VTACH) found that prophylactic catheter ablation reduces the incidence of appropriate ICD therapy in patients who had undergone ICD implantation as a means of secondary prevention and had a history of myocardial infarction (MI) [16,17]. It was also shown in a small retrospective study that prophylactic catheter ablation for induced VT reduced the incidence of appropriate ICD therapy in primary prevention post-MI patients [18].
Aim of the study - Statement of Hypothesis Prophylactic substrate ablation in post-MI patients undergoing defibrillator implantation reduces appropriate defibrillator therapies.
Tipo de estudio
Inscripción (Anticipado)
Fase
- No aplica
Contactos y Ubicaciones
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
- Niño
- Adulto
- Adulto Mayor
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Descripción
Inclusion Criteria:
- Post-MI patients eligible for ICD implantation in the setting of primary prevention
Exclusion Criteria:
- NYHA IV or ambulatory NYHA IV
- Acute coronary syndrome in the last 40 days
- Stable angina not eligible to revascularization
- Revascularization in the last 3 months (except MI)
- Antiarrhythmic therapy other than b-blockers
- LVEF<20%
- GFR<30ml/min/1.73m2
- Systematic illnesses
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Prevención
- Asignación: Aleatorizado
- Modelo Intervencionista: Asignación paralela
- Enmascaramiento: Ninguno (etiqueta abierta)
Armas e Intervenciones
Grupo de participantes/brazo |
Intervención / Tratamiento |
|---|---|
|
Comparador activo: Prophylactic substrate ablation group
Prophylactic substrate ablation group will undergo substrate mapping and ventricular tachycardia substrate ablation
|
Study protocol
Programmed ventricular stimulation with up to 4 extrastimuli from LV is performed and repeated at the end of the procedure in patients undergoing substrate ablation. |
|
Sin intervención: Control group
Control group will undergo substrate mapping
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Appropriate ICD activation therapies
Periodo de tiempo: Within 3 years after ICD implantation
|
All post-MI patients will undergo ICD implantation and electroanatomical substrate mapping of the left ventricle. Half patients will also undergo prophylactic VT ablation aiming to late and early potentials elimination. Post-MI patients who underwent ICD implantation in the setting of primary prevention and prophylactic substrate ablation will have significant less appropriate ICD therapies. |
Within 3 years after ICD implantation
|
Colaboradores e Investigadores
Patrocinador
Colaboradores
Investigadores
- Investigador principal: George Giannopoulos, MD, Attikon Hospital, University of Athens
- Investigador principal: Charis Kossyvakis, MD, Athens General Hospital "G. Gennimatas"
- Investigador principal: Spyros Deftereos, MD, Attikon Hospital, University of Athens
- Investigador principal: Dimitris Tsiachris, MD, Athens Heart Center, Athens Medical Center
Publicaciones y enlaces útiles
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio
Finalización primaria (Anticipado)
Finalización del estudio (Anticipado)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Estimar)
Actualizaciones de registros de estudio
Última actualización publicada (Estimar)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
- PREVENT-VT study
Plan de datos de participantes individuales (IPD)
¿Planea compartir datos de participantes individuales (IPD)?
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .