Reliability of the Freestyle Libre CGM in the Inpatient Setting During the COVID-19 Surge

1 de marzo de 2021 actualizado por: Northwell Health
The FDA has provided an emergency waiver for the use of non-invasive continuous glucose monitors (CGM) in hospitals, so frontline health care providers (in hospitals) can remotely monitor patients with diabetes thus reducing patient's discomfort, limiting exposure to COVID-19 and preserving critical personal protective equipment (PPE). The FreeStyle Libre 14-day system is a continuous glucose monitoring system consisting of a handheld reader (smart phone may be used) and a sensor applied with adhesive to back of the upper arm. In order to evaluate the reliability of the Freestyle Libre CGM for in-patient use, we propose a study which will examine the correlation between the libre CGM data and capillary blood glucose test - the current standard of care taken by the Accuchek Inform II platform.

Descripción general del estudio

Descripción detallada

In hospitalized patients diagnosed with COVID-19, diabetes mellitus is associated with a higher mortality. Patients with controlled blood glucose have a lower mortality rate than those who are uncontrolled. However, a rigid blood glucose control - which may lead to hypoglycemia- is associated with higher mortality rates. Thus, adequate glucose monitoring is important for hospitalized diabetic patients.

Previous studies have shown that CGMS, in the outpatient setting, engender better glycemic control thereby reducing risk of hypoglycemia. CGMS offer a replacement for finger stick blood glucose monitoring which may not identify an incidence of hypoglycemia until symptoms drive the patient to test. Furthermore, finger stick blood glucose monitoring is painful and time consuming thus causing many patients to avoid this aspect of diabetes self-care management.

Freestyle Libre CGMs sample interstitial fluid glucose subcutaneously. Measurement frequencies typically range from 1 to 15 minutes and most commonly are every 5 minutes.

Previous studies in hospitalized patients living with diabetes mellitus on basal bolus regimen have shown:

• Use of the CGM increased detection of both hypoglycemic and hyperglycemic events versus those sensed by POCT.

One investigation identified 88 postprandial hyperglycemic excursions in patients with CGM use as opposed to 61 in those with POCT. Another noted that when comparing the CGM use with that of POCT, the former identified 55 hypoglycemic events whereas the latter only found 12.

• No difference in mean daily glucose CGM and POCT readings. In a study of 38 patients, the investigators noted no difference in mean daily glucose between the CGM and POCT.

Tipo de estudio

Intervencionista

Inscripción (Actual)

52

Fase

  • No aplica

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Ubicaciones de estudio

    • New York
      • New York, New York, Estados Unidos, 10022
        • Lenox Hill Hospital

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

18 años a 99 años (Adulto, Adulto Mayor)

Acepta Voluntarios Saludables

No

Géneros elegibles para el estudio

Todos

Descripción

Inclusion Criteria:

  • Participants acquired from among all non-critical care in patients who are living with Diabetes Mellitus. Because the patients will have to be instructed on the use of the CGM, this study will be limited to English speaking/reading adults (18 years of age or older), who possess the cognitive and physical ability to participate.

Exclusion Criteria:

  • Minors, pregnant women, and critically ill.

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Propósito principal: Otro
  • Asignación: No aleatorizado
  • Modelo Intervencionista: Asignación cruzada
  • Enmascaramiento: Ninguno (etiqueta abierta)

Armas e Intervenciones

Grupo de participantes/brazo
Intervención / Tratamiento
Otro: Freestyle Libre 14-day CGM
The FreeStyle Libre 14 day system is a continuous glucose monitoring system consisting of a handheld reader and a sensor worn on the back of the upper arm.
The FreeStyle Libre 14 day system is a continuous glucose monitoring system consisting of a handheld reader and a sensor worn on the back of the upper arm.
The Accu-Chek Inform II system is designed to deliver data with speed and efficiency, helping to provide optimal care. Wireless meter quickly transfers data. The Accu-Chek Inform II system is the first point-of-care blood glucose device to offer truly wireless technology at the meter level.
Otro: Accuchek Inform II meter
ACCU-CHEK INFORM II system quantitatively measures glucose in fresh venous, arterial, neonatal heel stick and capillary whole blood from the finger and is used as an aid in monitoring the effectiveness of glucose control
The FreeStyle Libre 14 day system is a continuous glucose monitoring system consisting of a handheld reader and a sensor worn on the back of the upper arm.
The Accu-Chek Inform II system is designed to deliver data with speed and efficiency, helping to provide optimal care. Wireless meter quickly transfers data. The Accu-Chek Inform II system is the first point-of-care blood glucose device to offer truly wireless technology at the meter level.

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Comparison of values between two devices
Periodo de tiempo: Through end of patient hospitalization, an average of 14 days
Correlation between blood glucose results from the Freestlye Libre 14-day CGM and Accuchek Inform II platform using the Bland-Altman method to determine whether the two glucose methods agree
Through end of patient hospitalization, an average of 14 days

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Patrocinador

Investigadores

  • Investigador principal: Renee Murray-Bachmann, Ed.D, MSN, Northwell Health

Publicaciones y enlaces útiles

La persona responsable de ingresar información sobre el estudio proporciona voluntariamente estas publicaciones. Estos pueden ser sobre cualquier cosa relacionada con el estudio.

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio (Actual)

12 de junio de 2020

Finalización primaria (Actual)

30 de noviembre de 2020

Finalización del estudio (Actual)

30 de noviembre de 2020

Fechas de registro del estudio

Enviado por primera vez

1 de junio de 2020

Primero enviado que cumplió con los criterios de control de calidad

3 de junio de 2020

Publicado por primera vez (Actual)

4 de junio de 2020

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

2 de marzo de 2021

Última actualización enviada que cumplió con los criterios de control de calidad

1 de marzo de 2021

Última verificación

1 de marzo de 2021

Más información

Términos relacionados con este estudio

Otros números de identificación del estudio

  • 20-0455

Plan de datos de participantes individuales (IPD)

¿Planea compartir datos de participantes individuales (IPD)?

NO

Descripción del plan IPD

The team has not decided whether to share the results with other researchers. The team will consider publishing results after study completion

Información sobre medicamentos y dispositivos, documentos del estudio

Estudia un producto farmacéutico regulado por la FDA de EE. UU.

No

Estudia un producto de dispositivo regulado por la FDA de EE. UU.

Sí

producto fabricado y exportado desde los EE. UU.

Sí

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .