Reliability of the Freestyle Libre CGM in the Inpatient Setting During the COVID-19 Surge
A tanulmány áttekintése
Állapot
Körülmények
Beavatkozás / kezelés
Részletes leírás
In hospitalized patients diagnosed with COVID-19, diabetes mellitus is associated with a higher mortality. Patients with controlled blood glucose have a lower mortality rate than those who are uncontrolled. However, a rigid blood glucose control - which may lead to hypoglycemia- is associated with higher mortality rates. Thus, adequate glucose monitoring is important for hospitalized diabetic patients.
Previous studies have shown that CGMS, in the outpatient setting, engender better glycemic control thereby reducing risk of hypoglycemia. CGMS offer a replacement for finger stick blood glucose monitoring which may not identify an incidence of hypoglycemia until symptoms drive the patient to test. Furthermore, finger stick blood glucose monitoring is painful and time consuming thus causing many patients to avoid this aspect of diabetes self-care management.
Freestyle Libre CGMs sample interstitial fluid glucose subcutaneously. Measurement frequencies typically range from 1 to 15 minutes and most commonly are every 5 minutes.
Previous studies in hospitalized patients living with diabetes mellitus on basal bolus regimen have shown:
• Use of the CGM increased detection of both hypoglycemic and hyperglycemic events versus those sensed by POCT.
One investigation identified 88 postprandial hyperglycemic excursions in patients with CGM use as opposed to 61 in those with POCT. Another noted that when comparing the CGM use with that of POCT, the former identified 55 hypoglycemic events whereas the latter only found 12.
• No difference in mean daily glucose CGM and POCT readings. In a study of 38 patients, the investigators noted no difference in mean daily glucose between the CGM and POCT.
Tanulmány típusa
Beiratkozás (Tényleges)
Fázis
- Nem alkalmazható
Kapcsolatok és helyek
Tanulmányi helyek
-
-
New York
-
New York, New York, Egyesült Államok, 10022
- Lenox Hill Hospital
-
-
Részvételi kritériumok
Jogosultsági kritériumok
Tanulmányozható életkorok
Egészséges önkénteseket fogad
Tanulmányozható nemek
Leírás
Inclusion Criteria:
- Participants acquired from among all non-critical care in patients who are living with Diabetes Mellitus. Because the patients will have to be instructed on the use of the CGM, this study will be limited to English speaking/reading adults (18 years of age or older), who possess the cognitive and physical ability to participate.
Exclusion Criteria:
- Minors, pregnant women, and critically ill.
Tanulási terv
Hogyan készül a tanulmány?
Tervezési részletek
- Elsődleges cél: Egyéb
- Kiosztás: Nem véletlenszerű
- Beavatkozó modell: Crossover kiosztás
- Maszkolás: Nincs (Open Label)
Fegyverek és beavatkozások
Résztvevő csoport / kar |
Beavatkozás / kezelés |
|---|---|
|
Egyéb: Freestyle Libre 14-day CGM
The FreeStyle Libre 14 day system is a continuous glucose monitoring system consisting of a handheld reader and a sensor worn on the back of the upper arm.
|
The FreeStyle Libre 14 day system is a continuous glucose monitoring system consisting of a handheld reader and a sensor worn on the back of the upper arm.
The Accu-Chek Inform II system is designed to deliver data with speed and efficiency, helping to provide optimal care.
Wireless meter quickly transfers data.
The Accu-Chek Inform II system is the first point-of-care blood glucose device to offer truly wireless technology at the meter level.
|
|
Egyéb: Accuchek Inform II meter
ACCU-CHEK INFORM II system quantitatively measures glucose in fresh venous, arterial, neonatal heel stick and capillary whole blood from the finger and is used as an aid in monitoring the effectiveness of glucose control
|
The FreeStyle Libre 14 day system is a continuous glucose monitoring system consisting of a handheld reader and a sensor worn on the back of the upper arm.
The Accu-Chek Inform II system is designed to deliver data with speed and efficiency, helping to provide optimal care.
Wireless meter quickly transfers data.
The Accu-Chek Inform II system is the first point-of-care blood glucose device to offer truly wireless technology at the meter level.
|
Mit mér a tanulmány?
Elsődleges eredményintézkedések
Eredménymérő |
Intézkedés leírása |
Időkeret |
|---|---|---|
|
Comparison of values between two devices
Időkeret: Through end of patient hospitalization, an average of 14 days
|
Correlation between blood glucose results from the Freestlye Libre 14-day CGM and Accuchek Inform II platform using the Bland-Altman method to determine whether the two glucose methods agree
|
Through end of patient hospitalization, an average of 14 days
|
Együttműködők és nyomozók
Szponzor
Nyomozók
- Kutatásvezető: Renee Murray-Bachmann, Ed.D, MSN, Northwell Health
Publikációk és hasznos linkek
Hasznos linkek
- Flash Glucose-Sensing Technology as a Replacement for Blood Glucose Monitoring for the Management of Insulin-Treated Type 2 Diabetes: A Multicenter, Open-Label Randomize
- Zhu, L., Zhi-Gang, S., Cheng, S., Guo, J., Bing-Hong, Z.,Hongliang, L. (2020).Association of blood glucose control and outcomes in patients with COVID-19 and pre-existing Type 2 Diabetes Cell Metabolism, 31, (2020).pp.1-10
Tanulmányi rekorddátumok
Tanulmány főbb dátumok
Tanulmány kezdete (Tényleges)
Elsődleges befejezés (Tényleges)
A tanulmány befejezése (Tényleges)
Tanulmányi regisztráció dátumai
Először benyújtva
Először nyújtották be, amely megfelel a minőségbiztosítási kritériumoknak
Első közzététel (Tényleges)
Tanulmányi rekordok frissítései
Utolsó frissítés közzétéve (Tényleges)
Az utolsó frissítés elküldve, amely megfelel a minőségbiztosítási kritériumoknak
Utolsó ellenőrzés
Több információ
A tanulmányhoz kapcsolódó kifejezések
Egyéb vizsgálati azonosító számok
- 20-0455
Terv az egyéni résztvevői adatokhoz (IPD)
Tervezi megosztani az egyéni résztvevői adatokat (IPD)?
IPD terv leírása
Gyógyszer- és eszközinformációk, tanulmányi dokumentumok
Egy amerikai FDA által szabályozott gyógyszerkészítményt tanulmányoz
Egy amerikai FDA által szabályozott eszközterméket tanulmányoz
az Egyesült Államokban gyártott és onnan exportált termék
Ezt az információt közvetlenül a clinicaltrials.gov webhelyről szereztük be, változtatás nélkül. Ha bármilyen kérése van vizsgálati adatainak módosítására, eltávolítására vagy frissítésére, kérjük, írjon a következő címre: register@clinicaltrials.gov. Amint a változás bevezetésre kerül a clinicaltrials.gov oldalon, ez a webhelyünkön is automatikusan frissül. .