- ICH GCP
- Registro de ensayos clínicos de EE. UU.
- Ensayo clínico NCT07610460
Thyroid Uptake Quantification Validation on a Three-dimensional (3D) Cadmium-Zinc-Telluride (CZT) New Generation Gamma Camera (QThy2Dvc3D)
Clinical Evaluation of Thyroid Uptake Quantification With Technetium-99m (99mTc)-Pertechnetate: Comparison Between Gold Standard Planar and Quantitative 3D CZT Single Photon Emission Computed Tomography/Cumputed Tomography (SPECT/CT) Scintigraphy
Descripción general del estudio
Estado
Condiciones
Intervención / Tratamiento
Descripción detallada
Planar and SPECT/CT scintigraphy will be performed on a new generation 3D CZT gamma camera and thyroid uptake (TU) value will be calculated on planar acquisition for 27 consecutive patients referred in the department of the investigators for hyper or hypothyroidism.
With a quantitative approach using attenuation, scatter correction and iterative algorithm (12 iterations and 8 subsets) with post filter Median Full Width at Half Maximum (FWHM=3), the TU value with SPECT or SPECT/CT acquisitions can be calculate.
The objective will be to evaluate the potential of a new 3D CZT gamma camera to estimate the thyroid uptake on SPECT (Tomography without attenuation correction) and SPECT/CT (tomography with attenuation correction) acquisitions compared with standard planar scintigraphy as a gold standard.
To established this study it will be necessary to introduce cross-calibration factors performed from homogeneous phantoms, for planar and 3D SPECT acquisitions, to estimate the thyroid uptake values.
Tipo de estudio
Inscripción (Actual)
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
-
Monaco, Mónaco, 98000
- Centre Hospitalier Princesse Grace
-
-
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
- Adulto
- Adulto Mayor
Acepta Voluntarios Saludables
Método de muestreo
Población de estudio
Descripción
Inclusion Criteria:
- hypothyroidism
- hyperthyroidism
Exclusion Criteria:
- Pregnant women
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Periodo de tiempo |
|---|---|
|
Quantification of thyroid uptake on a 3D CZT gamma camera
Periodo de tiempo: Day 1
|
Day 1
|
Colaboradores e Investigadores
Patrocinador
Publicaciones y enlaces útiles
Publicaciones Generales
- Ritt P, Vija H, Hornegger J, Kuwert T. Absolute quantification in SPECT. Eur J Nucl Med Mol Imaging. 2011 May;38 Suppl 1:S69-77. doi: 10.1007/s00259-011-1770-8. Epub 2011 Apr 12.
- Gnesin S, Leite Ferreira P, Malterre J, Laub P, Prior JO, Verdun FR. Phantom Validation of Tc-99m Absolute Quantification in a SPECT/CT Commercial Device. Comput Math Methods Med. 2016;2016:4360371. doi: 10.1155/2016/4360371. Epub 2016 Dec 14.
- Giovanella L, Avram AM, Iakovou I, Kwak J, Lawson SA, Lulaj E, Luster M, Piccardo A, Schmidt M, Tulchinsky M, Verburg FA, Wolin E. EANM practice guideline/SNMMI procedure standard for RAIU and thyroid scintigraphy. Eur J Nucl Med Mol Imaging. 2019 Nov;46(12):2514-2525. doi: 10.1007/s00259-019-04472-8. Epub 2019 Aug 7.
- Mariani G, Tonacchera M, Grosso M, Orsolini F, Vitti P, Strauss HW. The Role of Nuclear Medicine in the Clinical Management of Benign Thyroid Disorders, Part 1: Hyperthyroidism. J Nucl Med. 2021 Mar;62(3):304-312. doi: 10.2967/jnumed.120.243170. Epub 2020 Oct 2.
- Serrano B, Amblard R, Beaumont T, Hugonnet F, Dietz M, Berthier F, Garnier N, Villeneuve R, Nataf V, Mocquot F, Montemagno C, Faraggi M, Paulmier B. Quantitative analysis of 99mTc-pertechnetate thyroid uptake with a large-field CZT gamma camera: feasibility and comparison between SPECT/CT and planar acquisitions. EJNMMI Phys. 2023 Jul 31;10(1):45. doi: 10.1186/s40658-023-00566-3.
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Actual)
Finalización primaria (Actual)
Finalización del estudio (Actual)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
- 26-05
Plan de datos de participantes individuales (IPD)
¿Planea compartir datos de participantes individuales (IPD)?
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .