Esta página se tradujo automáticamente y no se garantiza la precisión de la traducción. por favor refiérase a versión inglesa para un texto fuente.

Jaw Tracking Impact on Occlusion and Patient Outcomes in Maxillary Implant Restorations

3 de julio de 2026 actualizado por: Shahira Saad Abd ElKhabeer Mohamed Elsyed Ali, Mansoura University

Jaw Tracking Impact on Occlusion and Patient Outcomes in Maxillary Implant Restorations: Randomized Clinical Trial

This randomized clinical trial aims to evaluate the effect of integrating digital jaw tracking into the workflow for fabrication of full-arch maxillary implant-supported screw-retained restorations. Twenty completely edentulous maxillary patients opposing natural mandibular dentition will be randomly assigned to either a conventional workflow group or a digital jaw-tracking workflow group. The study will compare patient satisfaction and occlusal accuracy between the two groups. Patient satisfaction will be assessed using a visual analogue scale (VAS), while occlusal accuracy will be evaluated using the OccluSense system.

Descripción general del estudio

Descripción detallada

This randomized clinical trial will compare conventional prosthetic workflow with a digital jaw-tracking workflow for the fabrication of full-arch maxillary implant-supported screw-retained restorations.

Twenty edentulous patients with completely edentulous maxillary arches opposing natural mandibular dentition will be recruited and randomly allocated into two equal groups. Group A will receive restorations fabricated using the conventional workflow with static jaw relation records, while Group B will receive restorations fabricated using a digital workflow incorporating dynamic jaw tracking and a virtual articulator.

The primary outcome will be patient satisfaction, assessed using a visual analogue scale (VAS) after prosthesis insertion and during follow-up visits. Occlusal accuracy will be evaluated using the OccluSense digital occlusal analysis system. The study aims to determine whether digital jaw tracking improves occlusal accuracy and patient-reported outcomes compared with the conventional workflow.

Tipo de estudio

Intervencionista

Inscripción (Estimado)

20

Fase

  • No aplica

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Estudio Contacto

Ubicaciones de estudio

    • Dakahlia Governorate
      • Al Mansurah, Dakahlia Governorate, Egipto
        • Reclutamiento
        • Faculty of Dentistry, Mansoura University

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

  • Adulto
  • Adulto Mayor

Acepta Voluntarios Saludables

No

Descripción

Inclusion Criteria:

  • Male or female patients aged 50 to 70 years.
  • Completely edentulous maxillary arch opposing natural mandibular dentition.
  • Skeletal Class I maxillomandibular relationship with normal occlusion.
  • Acceptable oral hygiene.
  • Willing and able to provide written informed consent and comply with study procedures.

Exclusion Criteria:

  • Systemic diseases affecting bone healing, such as uncontrolled diabetes mellitus or osteoporosis.
  • Harmful oral habits, including smoking, clenching, or bruxism.
  • Uncooperative patients or patients unable to comply with study procedures.

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Propósito principal: Tratamiento
  • Asignación: Aleatorizado
  • Modelo Intervencionista: Asignación paralela
  • Enmascaramiento: Ninguno (etiqueta abierta)

Armas e Intervenciones

Grupo de participantes/brazo
Intervención / Tratamiento
Comparador activo: Conventional Workflow
Participants will receive full-arch maxillary implant-supported screw-retained restorations fabricated using the conventional workflow with conventional jaw relation records and standard occlusal adjustment procedures.
Fabrication of a full-arch maxillary implant-supported screw-retained prosthesis using conventional jaw relation records, a facebow or average-value articulator, and conventional occlusal adjustment procedures.
Experimental: Digital Jaw-Tracking Workflow
Participants will receive full-arch maxillary implant-supported screw-retained restorations fabricated using a digital workflow incorporating dynamic jaw tracking and a virtual articulator for patient-specific occlusal design.
Fabrication of a full-arch maxillary implant-supported screw-retained prosthesis using a digital workflow with dynamic jaw tracking, virtual articulator integration, and CAD/CAM technology for patient-specific occlusal design.

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Patient Satisfaction
Periodo de tiempo: At prosthesis insertion, 3 months, and 6 months after prosthesis insertion
Patient satisfaction will be assessed using a Visual Analogue Scale (VAS) to evaluate patient satisfaction with the implant-supported prosthesis regarding comfort, chewing ability, aesthetics, and phonetics.
At prosthesis insertion, 3 months, and 6 months after prosthesis insertion

Medidas de resultado secundarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Occlusal Accuracy
Periodo de tiempo: At prosthesis insertion and 3 months after insertion
Occlusal accuracy will be evaluated using the OccluSense digital occlusal analysis system by assessing the distribution and stability of occlusal contact points.
At prosthesis insertion and 3 months after insertion

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Patrocinador

Investigadores

  • Investigador principal: Shahira S Mohamed, BDS, Faculty of Dentistry, Mansoura University

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio (Actual)

25 de diciembre de 2025

Finalización primaria (Estimado)

25 de diciembre de 2026

Finalización del estudio (Estimado)

25 de enero de 2027

Fechas de registro del estudio

Enviado por primera vez

3 de julio de 2026

Primero enviado que cumplió con los criterios de control de calidad

3 de julio de 2026

Publicado por primera vez (Actual)

9 de julio de 2026

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

9 de julio de 2026

Última actualización enviada que cumplió con los criterios de control de calidad

3 de julio de 2026

Última verificación

1 de julio de 2026

Más información

Términos relacionados con este estudio

Plan de datos de participantes individuales (IPD)

¿Planea compartir datos de participantes individuales (IPD)?

NO

Descripción del plan IPD

There is no current plan to share individual participant data. Participant confidentiality will be maintained according to institutional ethical requirements.

Información sobre medicamentos y dispositivos, documentos del estudio

Estudia un producto farmacéutico regulado por la FDA de EE. UU.

No

Estudia un producto de dispositivo regulado por la FDA de EE. UU.

No

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .

Suscribir