Intra-observer and inter-observer reliability of leg circumference measurement among six observers: a single blinded randomized trial

Y Bakar, Ö C Özdemir, S Sevim, E Duygu, A Tuğral, M Sürmeli, Y Bakar, Ö C Özdemir, S Sevim, E Duygu, A Tuğral, M Sürmeli

Abstract

Hypothesis: Circumference measurement of extremities that was reported to be a reliable method as long as being standardized is commonly used both in clinical and home settings by clinicians or caregivers due to its cheapness and easy use. Objectives: The aims of this study were to determine the inter-observer and intra-observer reliability of manual circumference measurement among different observers and various measurement points. Methods and Results: A total of 58 lower limbs were included in the study. Both lower limbs of each subject were assessed by 6 observers randomly using circumference measurement method from 9 reference points specified with a Leg-O-Meter. All observers performed the measurements and they were blind to each other's measurements. Results: Measurement results from reference points were statistically significant between good to perfect (ICC 0.65-0.99, p<0.001). Interrater reliability of all observers' first and second measurements showed perfect reliability for both measurements (ICC: 0.92-0.99, p<0.001). Conclusions: This study demonstrated that the lower extremity manual circumference measurement is a reliable method for clinical practice. Abbreviations: BMI = Body Mass Index, ICC = Intraclass Correlation Coefficient, Metatarsal heads (cA), Ankle-heel (cY), Ankle (cB), Distal beginning point of gastrocnemius (cB1), The widest point for gastrocnemius (cC), Head of fibula (cD), Midline of knee (cE), Midline of thigh (cF), Groin level (cG).

Keywords: circumference measurement; inter-observer reliability; intra-observer reliability; lower extremity; reproducibility of results.

Figures

Fig. 1
Fig. 1
Marked measurement points
Fig. 2
Fig. 2
One of the authors measuring the ankle

References

    1. Allington NJ, Leroy N, Doneux C. Ankle joint range of motion measurements in spastic cerebral palsy children: intra-observer and inter-observer reliability and reproducibility of goniometry and visual estimation. J Pediatr Orthop B. 2002;11(3):236–239.
    1. Mayrovitz HN, Sims N, Macdonald J. Assessment of limb volume by manual and automated methods in patients with limb edema or lymphedema. Adv Skin Wound Care. 2000;13(6):272.
    1. Roeckaerts F, Vanden Bussche G. Double-blind placebo-controlled studies with flunarizine in venous insufficiency. Angiology. 1980;31(12):833–845.
    1. Czerniec S, Ward L, Refshauge KM, Beith J, Lee MJ, York S, Kilbreath SL. Assessment of breast cancer-related arm lymphedema—comparison of physical measurement methods and self-report. Cancer Invest. 2010;28(1):54–62.
    1. Ng M, Munnoch A. Clinimetrics of volume measurement in upper limb LE. J Lymphoedema. 2010;5:62–67.
    1. Sander AP, Hajer NM, Hemenway K, Miller AC. Upper-extremity volume measurements in women with lymphedema: a comparison of measurements obtained via water displacement with geometrically determined volume. Phys Ther. 2002;82(12):1201.
    1. Smoot BJ, Wong JF, Dodd MJ. Comparison of diagnostic accuracy of clinical measures of breast cancer–related lymphedema: area under the curve. Arch Phys Med Rehabil. 2011;92(4):603–610.
    1. Tunc R, Caglayan-Tunc A, Kisakol G, Unler GK, Hidayetoglu T, Yazici H. Intra-observer and inter-observer agreements of leg circumference measurements by tape measure based on 3 reference points. Angiology. 2007;58(5):593–596.
    1. Taylor R, Jayasinghe UW, Koelmeyer L, Ung O, Boyages J. Reliability and validity of arm volume measurements for assessment of lymphedema. Phys Ther. 2006;86(2):205.
    1. Meijer R, Rietman J, Geertzen J, Bosmans J, Dijkstra P. Validity and intra-and inter-observer reliability of an indirect volume measurements in patients with upper extremity lymphedema. Lymphology. 2004;37(3):127–133.
    1. Bérard A, Kurz X, Zuccarelli F, Abenhaim L. Validity of the Leg-O-Meter, an instrument to measure leg circumference. Angiology. 2002 ;53(1):21–28.
    1. Tidhar D, Armer JM, Deutscher D, Shyu C-R, Azuri J, Madsen R. Measurement Issues in Anthropometric Measures of Limb Volume Change in Persons at Risk for and Living with Lymphedema: A Reliability Study. J Pers . 2015 ;5(4):341–353.
    1. Elveru RA, Rothstein JM, Lamb RL. Goniometric reliability in a clinical setting. Phys Ther. 1988 ;68(5):672–677.
    1. Nunes GS, Bayer GS, da Costa LM, de Noronha M. Intra-observer and inter-observer reliability of a method to measure ankle plantar-flexion range of motion in the hook-lying position. J Sport Rehabil. 2012 :1–4.
    1. Guex J, Perrin M. Edema and leg volume: methods of assessment. Angiology. 2000 ;51(1):9–12.
    1. Pani S, Vanamail P, Yuvaraj J. Limb circumference measurement for recording edema volume in patients with filarial lymphedema. Lymphology. 1995 ;28(2):57–63.
    1. Stanton A, Badger C, Sitzia J. Non-invasive assessment of the lymphedematous limb. Lymphology. 2000 ;33(3):122–135.
    1. Deltombe T, Jamart J, Recloux S, Legrand C, Vandenbroeck N, Theys S, Hanson P. Reliability and limits of agreement of circuferential, water displacement, and optoelectronic volumetry in the measurement of upper limb lymphedema. Lymphology. 2007 ;40(1):26.
    1. Campagna G, Zampetti S, Gallozzi A, Giansanti S, Chiesa C, Pacifico L, Buzzetti R. Excellent intra and inter-observer reproducibility of wrist circumference measurements in obese children and adolescents. PloS one. 2016 ;11(6):e0156646.
    1. Wang C-Y, Liu M-H, Chen Y-C. Intrarater reliability and the value of real change for waist and hip circumference measures by a novice rater. Percept Mot Skills. 2010 ;110(3_suppl):1053–1058.

Source: PubMed

3
Suscribir