PRe-hospital Evaluation of Sensitive TrOponin (PRESTO) Study: multicentre prospective diagnostic accuracy study protocol

Abdulrhman Alghamdi, Eloïse Cook, Edward Carlton, Aloysius Siriwardena, Mark Hann, Alexander Thompson, Angela Foulkes, John Phillips, Jamie Cooper, Steve Bell, Kim Kirby, Andy Rosser, Richard Body, Abdulrhman Alghamdi, Eloïse Cook, Edward Carlton, Aloysius Siriwardena, Mark Hann, Alexander Thompson, Angela Foulkes, John Phillips, Jamie Cooper, Steve Bell, Kim Kirby, Andy Rosser, Richard Body

Abstract

Introduction: Within the UK, chest pain is one of the most common reasons for emergency (999) ambulance calls and the most common reason for emergency hospital admission. Diagnosing acute coronary syndromes (ACS) in a patient with chest pain in the prehospital setting by a paramedic is challenging. The Troponin-only Manchester Acute Coronary Syndromes (T-MACS) decision rule is a validated tool used in the emergency department (ED) to stratify patients with suspected ACS following a single blood test.We are seeking to evaluate the diagnostic accuracy of the T-MACS decision aid algorithm to 'rule out' ACS when used in the prehospital environment with point-of-care troponin assays. If successful, this could allow paramedics to immediately rule out ACS for patients in the 'very low risk' group and avoid the need for transport to the ED, while also risk stratifying other patients using a single blood sample taken in the prehospital setting.

Methods and analysis: We will recruit patients who call emergency (999) ambulance services where the responding paramedic suspects cardiac chest pain. The data required to apply T-MACS will be prospectively recorded by paramedics who are responding to each patient. Paramedics will be required to draw a venous blood sample at the time of arrival to the patient. Blood samples will later be tested in batches for cardiac troponin, using commercially available troponin assays. The primary outcome will be a diagnosis of acute myocardial infarction, established at the time of initial hospital admission. The secondary outcomes will include any major adverse cardiac events within 30 days of enrolment.

Ethics and dissemination: The study obtained approval from the National Research Ethics Service (reference: 18/ES/0101) and the Health Research Authority. We will publish our findings in a high impact general medical journal.

Trial registration number: Registration number: ClinicalTrials.gov, study ID: NCT03561051.

Keywords: accident & emergency medicine; myocardial infarction; pre-hospital.

Conflict of interest statement

Competing interests: We received funding from Abbott Point of Care. Also received donation of reagents from Roche Diagnostics International Ltd and LumiraDx.

© Author(s) (or their employer(s)) 2019. Re-use permitted under CC BY. Published by BMJ.

References

    1. Bandstein N, Ljung R, Johansson M, et al. . Undetectable high-sensitivity cardiac troponin T level in the emergency department and risk of myocardial infarction. J Am Coll Cardiol 2014;63:2569–78. 10.1016/j.jacc.2014.03.017
    1. Than M, Cullen L, Reid CM, et al. . A 2-h diagnostic protocol to assess patients with chest pain symptoms in the Asia-Pacific region (aspect): a prospective observational validation study. The Lancet 2011;377:1077–84. 10.1016/S0140-6736(11)60310-3
    1. Pope JH, Aufderheide TP, Ruthazer R, et al. . Missed diagnoses of acute cardiac ischemia in the emergency department. N Engl J Med 2000;342:1163–70. 10.1056/NEJM200004203421603
    1. Body R, Carlton E, Sperrin M, et al. . Troponin-only Manchester acute coronary syndromes (T-MACS) decision aid: single biomarker re-derivation and external validation in three cohorts. Emerg Med J 2017;34:349–56. 10.1136/emermed-2016-205983
    1. Body R, Almashali M, Morris N, et al. . Diagnostic accuracy of the T-MACS decision aid with a contemporary point-of-care troponin assay. Heart 2019;105:768–74. 10.1136/heartjnl-2018-313825
    1. Greenslade JH, Nayer R, Parsonage W, et al. . Validating the Manchester acute coronary syndromes (MACS) and Troponin-only Manchester acute coronary syndromes (T-MACS) rules for the prediction of acute myocardial infarction in patients presenting to the emergency department with chest pain. Emerg Med J 2017;34:517–23. 10.1136/emermed-2016-206366
    1. Va Den Berg P, Burrows G, Lewis P, et al. . Validation of the (Troponin-only) Manchester ACS decision aid with a contemporary cardiac troponin I assay. Am J Emerg Med 2018;36:602–7. 10.1016/j.ajem.2017.09.032
    1. National Institute of Clinical Excellence Guide to the methods of technology appraisal. National Institute of clinical excellence 2004.
    1. Amsterdam EA, Wenger NK, Brindis RG, et al. . 2014 AHA/ACC guideline for the management of patients with Non–ST-Elevation acute coronary syndromes: Executive summary. Circulation 2014;130:2354–94. 10.1161/CIR.0000000000000133
    1. Body R, Burrows G, Carley S, et al. . The Manchester acute coronary syndromes (MACS) decision rule: validation with a new automated assay for heart-type fatty acid binding protein. Emerg Med J 2015;32:769–74. 10.1136/emermed-2014-204235
    1. Thygesen K, Alpert JS, Jaffe AS, et al. . Fourth universal definition of myocardial infarction (2018). J Am Coll Cardiol 2018;72:2231–64. 10.1016/j.jacc.2018.08.1038
    1. Curtis L. Unit costs of health and social care. personal social services research. unit Kent, United Kingdom, 2010. Available:
    1. Armstrong S, Langlois A, Laparidou D, et al. . Assessment of consent models as an ethical consideration in the conduct of prehospital ambulance randomised controlled clinical trials: a systematic review. BMC Med Res Methodol 2017;17:142 10.1186/s12874-017-0423-4

Source: PubMed

3
Suscribir