A Simple Strategy in Avulsion Flap Injury: Prediction of Flap Viability Using Wood's Lamp Illumination and Resurfacing with a Full-thickness Skin Graft
Hyoseob Lim, Dae Hee Han, Il Jae Lee, Myong Chul Park, Hyoseob Lim, Dae Hee Han, Il Jae Lee, Myong Chul Park
Abstract
Background: Extensive degloving injuries of the extremities usually result in necrosis of the flap, necessitating comprehensive skin grafting. Provided there is a sufficient tool to evaluate flap viability, full-thickness skin can be used from a nonviable avulsed flap. We used a Wood's lamp to determine the viability of avulsed flaps in the operation field after intravenous injection of fluorescein dye.
Methods: We experienced 13 cases during 16 months. Fifteen minutes after the intravenous injection of fluorescein dye, the avulsed skin flaps were examined and non-fluorescent areas were marked under Wood's lamp illumination. The marked area was defatted for full-thickness skin grafting. The fluorescent areas were sutured directly without tension. The non-fluorescent areas were covered by defatted skin. Several days later, there was soft tissue necrosis within the flap area. We measured necrotic area and revised the flap.
Results: Among all the cases, necrotic area was 21.3% of the total avulsed area. However, if we exclude three cases, one of a carelessly managed patient and two cases of the flaps were inappropriately applied, good results were obtained, with a necrotic area of only 8.4%. Eight patients needed split-thickness skin grafts, and heel pad reconstruction was performed with free flap.
Conclusions: A full-thickness skin graft from an avulsed flap is a good method for addressing aesthetic concerns without producing donor site morbidity. Fluorescein dye is a useful, simple, and cost-effective tool for evaluating flap viability. Avulsed flap injuries can be managed well with Wood's lamp illumination and a full-thickness skin graft.
Keywords: Dermis; Extremities; Skin transplantation; Soft tissue injuries; Tissue survival.
Conflict of interest statement
No potential conflict of interest relevant to this article was reported.
Figures
References
- Jeng SF, Wei FC. Technical refinement in the management of circumferentially avulsed skin of the leg. Plast Reconstr Surg. 1997;100:1434–1441.
- Nogueira A, Martinez MJ, Arriaga MJ, et al. Delayed full-thickness autografting of cryopreserved avulsed skin in degloving injuries of the extremities. Plast Reconstr Surg. 2001;107:1009–1013.
- Innis CO. Treatment of skin avulsion injures of the extremities. Br J Plast Surg. 1957;10:122–140.
- Zeligowski AA, Ziv I. How to harvest skin graft from the avulsed flap in degloving injuries. Ann Plast Surg. 1987;19:89–90.
- Goris RJ, Nicolai JP. A simple method of taking skin grafts from the avulsed flap in degloving injuries. Br J Plast Surg. 1982;35:58–59.
- Hsu WM, Wei FC, Lin CH, et al. The salvage of a degloved hand skin flap by arteriovenous shunting. Plast Reconstr Surg. 1996;98:146–150.
- Huemer GM, Schoeller T, Dunst KM, et al. Management of a traumatically avulsed skin-flap on the dorsum of the foot. Arch Orthop Trauma Surg. 2004;124:559–562.
- McKee DM, Edgerton MT., Jr The surgical treatment of lymphedema of the lower extremities. Plast Reconstr Surg Transplant Bull. 1959;23:480–492.
- Hidalgo DA. Lower extremity avulsion injuries. Clin Plast Surg. 1986;13:701–710.
- Mandel MA. The management of lower extremity degloving injuries. Ann Plast Surg. 1981;6:1–5.
- Corps BV, Littlewood M. Full-thickness skin replacement after traumatic avulsion. Br J Plast Surg. 1966;19:229–233.
- Farmer AW. Treatment of avulsed skin flaps. Ann Surg. 1939;110:951–959.
- Coryllos E, Dabbert O, Tracey E, et al. Treatment of an avulsed skin-flap involving the circumference of the entire lower leg: a case report. Ann Surg. 1960;151:437–440.
- Sloan GM, Sasaki GH. Noninvasive monitoring of tissue viability. Clin Plast Surg. 1985;12:185–195.
- Moyer HR, Losken A. Predicting mastectomy skin flap necrosis with indocyanine green angiography: the gray area defined. Plast Reconstr Surg. 2012;129:1043–1048.
- Phillips BT, Lanier ST, Conkling N, et al. Intraoperative perfusion techniques can accurately predict mastectomy skin flap necrosis in breast reconstruction: results of a prospective trial. Plast Reconstr Surg. 2012;129:778e–788e.
- Burnam JA. Intravenous fluorescein vascularity studies of a new technique: the subcutaneous pedicled extension flap. Arch Otolaryngol Head Neck Surg. 1993;119:1329–1336.
- Lange K, Boyd LJ. The use of fluorescein to determine the adequacy of circulation. Med Clin North Am. 1942;26:943–952.
- Thorvaldsson SE, Grabb WC. The intravenous fluorescein test as a measure of skin flap viability. Plast Reconstr Surg. 1974;53:576–578.
- McCraw JB, Myers B, Shanklin KD. The value of fluorescein in predicting the viability of arterialized flaps. Plast Reconstr Surg. 1977;60:710–719.
- Myers B, Donovan W. An evaluation of eight methods of using fluorescein to predict the viability of skin flaps in the pig. Plast Reconstr Surg. 1985;75:245–250.
- Singer R, Lewis CM, Franklin JD, et al. Fluorescein test for prediction of flap viability during breast reconstructions. Plast Reconstr Surg. 1978;61:371–375.
- Losken A, Styblo TM, Schaefer TG, et al. The use of fluorescein dye as a predictor of mastectomy skin flap viability following autologous tissue reconstruction. Ann Plast Surg. 2008;61:24–29.
- Pearl RM. A unifying theory of the delay phenomenon: recovery from the hyperadrenergic state. Ann Plast Surg. 1981;7:102–112.
- Morris SF, Taylor GI. The time sequence of the delay phenomenon: when is a surgical delay effective? An experimental study. Plast Reconstr Surg. 1995;95:526–533.
Source: PubMed