Can a surgeon drill accurately at a specified angle?

Valentina Brioschi, Jodie Cook, Gareth I Arthurs, Valentina Brioschi, Jodie Cook, Gareth I Arthurs

Abstract

Objectives: To investigate whether a surgeon can drill accurately a specified angle and whether surgeon experience, task repetition, drill bit size and perceived difficulty influence drilling angle accuracy.

Methods: The sample population consisted of final-year students (n=25), non-specialist veterinarians (n=22) and board-certified orthopaedic surgeons (n=8). Each participant drilled a hole twice in a horizontal oak plank at 30°, 45°, 60°, 80°, 85° and 90° angles with either a 2.5 or a 3.5 mm drill bit. Participants then rated the perceived difficulty to drill each angle. The true angle of each hole was measured using a digital goniometer.

Results: Greater drilling accuracy was achieved at angles closer to 90°. An error of ≤±4° was achieved by 84.5 per cent of participants drilling a 90° angle compared with approximately 20 per cent of participants drilling a 30-45° angle. There was no effect of surgeon experience, task repetition or drill bit size on the mean error for intended versus achieved angle. Increased perception of difficulty was associated with the more acute angles and decreased accuracy, but not experience level.

Clinical significance: This study shows that surgeon ability to drill accurately (within ±4° error) is limited, particularly at angles ≤60°. In situations where drill angle is critical, use of computer-assisted navigation or custom-made drill guides may be preferable.

Keywords: bone drilling; drill angle; drilling accuracy.

Figures

FIG 1:
FIG 1:
Box plot illustrating the error attained for each experience-level group at each specified drilling angle. The ends of the whiskers represent the lowest datum still within 1.5 IQR of the lower quartile, and the highest datum still within 1.5 IQR of the upper quartile. Any data not included between the whiskers was considered an outlier (represented with a dot). Outliers were the result of a participant drilling incorrectly at both attempts of the same angle; however, each outlying value relates to a separate participant (i.e. it was not the same individual drilling consistently at an incorrect angle)
FIG 2:
FIG 2:
Percentage of participants within groups achieving error margin ≤4°

References

    1. Amiot L. P., Lang K., Putzier M., Zippel H., Labelle H. (2000) Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine. Spine 25, 606–14
    1. Askeland D. R., Wright W. J. (2016) The Science and Engineering of Materials. 7th edn Boston: Cengage Learning. p 663
    1. Barnes D. M., Morris A. P., Anderson A. A. (2014) Defining a safe corridor for transcondylar screw insertion across the canine humeral condyle: a comparison of medial and lateral surgical approaches. Veterinary Surgery 43, 1020–31
    1. Cohen J. (1988) Statistical Power Analysis for the Behavioral Sciences. 2nd edn Mahwah: Erlbaum Associates Publishers.
    1. DeCamp C. E., Braden T. D. (1985) Sacroiliac fracture separation in the dog: a study of 92 cases. Veterinary Surgery 14, 127–130
    1. Ericsson K. A. (2004) Deliberate practice and the acquisition and maintenance of expert performance in medicine and related domains. Academic Medicine 79, S70–S81
    1. Hettlich B. F., Fosgate G. T., Levine J. M., Young B. D., Kerwin S. C., Walker M., Griffin J., Maierl J. (2010) Accuracy of conventional radiography and computed tomography in predicting implant position in relation to the vertebral canal in dogs. Veterinary Surgery 39, 680–687
    1. Kim Y. J., Lenke L. G., Bridwell K. H., Cho Y. S., Riew K. D. (2004) Free hand pedicle screw placement in the thoracic spine: is it safe? Spine 29, 333–342
    1. Kunkel K. A. R., Rusly R. J., Basinger R. R., DesJardins J. D., Gerard P. D (2011) In vitro acute load to failure and eyelet abrasion testing of a novel veterinary screw type mini anchor design. Veterinary Surgery 42, 217–222
    1. Leasure C. S., Lewis D. D., Sereda C. W., Mattern K. L., Jehn C. T., Wheeler J. L. (2007) Limited open reduction and stabilization of sacroiliac fracture-luxations using fluoroscopically assisted placement of a trans-iliosacral rod in five dogs. Veterinary Surgery 36, 633–43.
    1. Lombardo M. P., Deaner R. O. (2014) You can't teach speed: sprinter falsify the deliberate practice model of expertise. PeerJ 26, e445
    1. Lu S., Xu Y. Q., Chen G. P., Zhang Y. Z., Lu D., Chen Y. B., Shi J. H., Xu X. M. (2009) Rapid prototyping drill guide template for lumbar pedicle screw placement. Chinese Journal of Traumatology 12, 177–80
    1. Pandey R. K., Panda S. S. (2013) Drilling of bone: a comprehensive review. Journal of Clinical Orthopaedics and Trauma 4, 15–30
    1. Shales C., Moores A., Kulendra E., White C., Toscano M., Langley-Hobbs S. (2010) Stabilization of sacroiliac luxation in 40 cats using screws inserted in lag fashion. Veterinary Surgery 39, 696–700
    1. Shales C. J., Langley-Hobbs S. J. (2005) Canine sacroiliac luxation: anatomic study of dorsoventral articular surface angulation and safe corridor for placement of screws used for lag fixation. Veterinary Surgery 34, 324–331
    1. Shales C. J., White L., Langley-Hobbs S. J. (2009) Sacroiliac luxation in the cat: defining a safe corridor in the dorsoventral plane for screw insertion in lag fashion. Veterinary Surgery 38, 343–348
    1. Silbernagel J. T., Kennedy S. C., Johnson A. L., Pijanowski G. J., Ehrhart N., Schaeffer D. (2002) Validation of canine cancellous and cortical polyurethane foam bone models. Veterinary and Comparative Orthopaedics and Traumatology 15, 200–4
    1. Silveira F., Quinn R., Adrian A., Owen M., Bush M (2015) Evaluation of the use of intraoperative radiography for placement of lag screws for the stabilization of sacroiliac luxation in cats. Proceedings of the British Veterinary Orthopaedic Association Autumn Meeting. October 16 to 18, Windsor, UK: p 74
    1. Sparrow T., Heller J., Farrell M (2015) In vitro assessment of aiming bias in the frontal plane during orthopaedic drilling procedures. Veterinary Record 176, 412.
    1. Tomlison J. L. (2002) Sacroiliac fracture-luxation. In Textbook of Small Animal Surgery. 3rd edn Slatter D. Ed. Philadelphia: Saunders; pp 1990–1993
    1. Van Bruwaene S., Lissens A., De Win G., Neyrink B., Willy L., Schijven M., Miserez M (2015) Surgical skill: trick or trait? Journal of Surgical Education 72, 1247–1253
    1. Watine S., Cabassu J. P., Catheland S., Brochier L., Ivanoff S. (2006) Computed tomography study of implantation corridors in canine vertebrae. Journal of Small Animal Practice 47, 651–657
    1. Weh M., Kraus K. H. (2012) Thoracolumbar fractures and luxations. In Veterinary Surgery Small Animals. Tobias K. M., Johnston S. A. Eds. St Louis: Saunders Elsevier; pp 493–498
    1. Wheeler J. L., Cross A. R., Rapoff A. J. (2002) A comparison of the accuracy and safety of vertebral body pin placement using a fluoroscopically guided versus an open surgical approach. Veterinary Surgery 31, 468–474.

Source: PubMed

3
Suscribir