Point-of-Care Bedside Lung Ultrasound Examination Advanced Trial Protocol (PoCBLUEPlus)

keskiviikko 25. maaliskuuta 2015 päivittänyt: Hong Liu, Nanjing Medical University

A Prospective, Multi-center, Open-label and Double-blind, Standard-controlled, Non-inferiority, Diagnostic Study of Lung Ultrasound for Management of Mechanical Ventilation in Neonatal Acute Respiratory Distress Syndrome

The purpose of this study was to evaluate the availability and diagnostic accuracy of point-of-care bedside lung ultrasound examination in management of mechanical ventilation in neonatal acute respiratory distress syndrome.

Tutkimuksen yleiskatsaus

Yksityiskohtainen kuvaus

Neonatal acute respiratory distress syndrome (ARDS) is a critical condition requiring dynamic evaluation and interventions. Point-of-care bedside lung ultrasound examination (PoC-BLUE) is a noninvasive, readily available imaging modality that can complement physical and clinical evaluation.

At any time, most neonates and infants with ARDS in medical intensive care units (ICUs) require mechanical ventilation, making it one of the most frequently used critical care technologies. However, difficulties with regard to the accurate diagnosis of ARDS before administration of mechanical ventilation, dynamic monitoring of treatment effects during administration of mechanical ventilation, and decision-making of timing in weaning from mechanical ventilation, are often encountered in the majority neonates and infants who require mechanical ventilation.

Hence, techniques that expedite and advance the knowledge of the administration of mechanical ventilation should have an important clinical significance in the diagnosis, treatment and prognosis of ARDS.

Preliminary researches have suggested that BLUE has a high diagnostic accuracy in patients with acute respiratory failure, and has the potential to quantify the rate and degree of diaphragm thinning during mechanical ventilation, which may be useful to predict extubation success or failure during either spontaneous breathing (SB) or pressure support (PS) trials.

Unfortunately, few studies focus on the availability of PoC-BLUE in management of mechanical ventilation in neonatal acute respiratory distress syndrome. Also, they call into question the possible association of the demographic and clinical confounders with the diagnostic accuracy of PoC-BLUE for diagnosis, monitoring and prognosis of ARDS in the whole process of mechanical ventilation.

Given that a considerable need for a timely and dynamic diagnosis of severe condition and therapy evaluation during mechanical ventilation has been triggered to integrate the currently available bulk of knowledge and information, the objective of this study is to investigate the availability and diagnostic accuracy of PoC-BLUE Plus protocol in management of mechanical ventilation in ARDS.

Opintotyyppi

Interventio

Ilmoittautuminen (Todellinen)

1000

Vaihe

  • Ei sovellettavissa

Osallistumiskriteerit

Tutkijat etsivät ihmisiä, jotka sopivat tiettyyn kuvaukseen, jota kutsutaan kelpoisuuskriteereiksi. Joitakin esimerkkejä näistä kriteereistä ovat henkilön yleinen terveydentila tai aiemmat hoidot.

Kelpoisuusvaatimukset

Opintokelpoiset iät

1 päivä - 1 kuukausi (Lapsi)

Hyväksyy terveitä vapaaehtoisia

Ei

Sukupuolet, jotka voivat opiskella

Kaikki

Kuvaus

Inclusion Criteria:

  • All infants who present to the ICU with respiratory symptoms suspicious for ARDS, according to Pediatric Acute Respiratory Distress Syndrome: Consensus Recommendations From the Pediatric Acute Lung Injury Consensus Conference, which is proposed by The Pediatric Acute Lung Injury Consensus Conference Group.
  • In whom the treating Collaborative Review Groups of Poc-BLUE-Plus protocol believe would benefit from diagnostic imaging.

Exclusion Criteria:

  • Infants who arrive at the ICU with a previously performed chest radiography
  • Unstable infants with life-threatening injuries who require ongoing resuscitation

Opintosuunnitelma

Tässä osiossa on tietoja tutkimussuunnitelmasta, mukaan lukien kuinka tutkimus on suunniteltu ja mitä tutkimuksella mitataan.

Miten tutkimus on suunniteltu?

Suunnittelun yksityiskohdat

  • Ensisijainen käyttötarkoitus: Diagnostiikka
  • Jako: Satunnaistettu
  • Inventiomalli: Rinnakkaistehtävä
  • Naamiointi: Kaksinkertainen

Aseet ja interventiot

Osallistujaryhmä / Arm
Interventio / Hoito
Kokeellinen: Lung Ultrasound
In infants allocated to this arm Lung ultrasound for detection of ARDS will be performed before chest radiography.
Lung ultrasound evaluation is performed after clinical assessment and before chest radiography
Muut nimet:
  • Bedside Ultrasonography System
Active Comparator: Chest Radiography
In infants allocated to this arm chest radiography will be performed for the detection of indirect signs of ARDS without ultrasound evaluation.
Chest Radiography is performed after clinical evaluation without using ultrasound assessment.
Muut nimet:
  • Chest X-ray System

Mitä tutkimuksessa mitataan?

Ensisijaiset tulostoimenpiteet

Tulosmittaus
Toimenpiteen kuvaus
Aikaikkuna
Accuracy of Lung Ultrasound in Neonatal ARDS
Aikaikkuna: Accuracy will be measured at the end of clinical evaluation in the ICU, an expected average of 4 days
Accuracy of lung ultrasound and chest radiography will be measured using as gold standard the independent evaluation of the entire medical records by two expert emergency physicians blinded to the lung ultrasound results and radiographic reports (digitalized chest radiography images will be available).
Accuracy will be measured at the end of clinical evaluation in the ICU, an expected average of 4 days

Toissijaiset tulostoimenpiteet

Tulosmittaus
Toimenpiteen kuvaus
Aikaikkuna
Accuracy of Lung Ultrasound in the Ventilator-Associated Pneumonia
Aikaikkuna: Accuracy will be measured at the end of clinical evaluation in the ICU, an expected average of 4 days
Accuracy of lung ultrasound and chest radiography will be measured using as gold standard the independent evaluation of the entire medical records by two expert emergency physicians blinded to the lung ultrasound results and radiographic reports (digitalized chest radiography images will be available).
Accuracy will be measured at the end of clinical evaluation in the ICU, an expected average of 4 days
Accuracy of Lung Ultrasound in the Weaning of Ventilatory Support
Aikaikkuna: Accuracy will be measured at the end of clinical evaluation in the ICU, an expected average of 4 days
Accuracy of lung ultrasound and chest radiography will be measured using as gold standard the independent evaluation of the entire medical records by two expert emergency physicians blinded to the lung ultrasound results and radiographic reports (digitalized chest radiography images will be available).
Accuracy will be measured at the end of clinical evaluation in the ICU, an expected average of 4 days

Yhteistyökumppanit ja tutkijat

Täältä löydät tähän tutkimukseen osallistuvat ihmiset ja organisaatiot.

Julkaisuja ja hyödyllisiä linkkejä

Tutkimusta koskevien tietojen syöttämisestä vastaava henkilö toimittaa nämä julkaisut vapaaehtoisesti. Nämä voivat koskea mitä tahansa tutkimukseen liittyvää.

Opintojen ennätyspäivät

Nämä päivämäärät seuraavat ClinicalTrials.gov-sivustolle lähetettyjen tutkimustietueiden ja yhteenvetojen edistymistä. National Library of Medicine (NLM) tarkistaa tutkimustiedot ja raportoidut tulokset varmistaakseen, että ne täyttävät tietyt laadunvalvontastandardit, ennen kuin ne julkaistaan ​​julkisella verkkosivustolla.

Opi tärkeimmät päivämäärät

Opiskelun aloitus

Lauantai 1. maaliskuuta 2014

Ensisijainen valmistuminen (Todellinen)

Sunnuntai 1. maaliskuuta 2015

Opintojen valmistuminen (Todellinen)

Sunnuntai 1. maaliskuuta 2015

Opintoihin ilmoittautumispäivät

Ensimmäinen lähetetty

Sunnuntai 22. maaliskuuta 2015

Ensimmäinen toimitettu, joka täytti QC-kriteerit

Keskiviikko 25. maaliskuuta 2015

Ensimmäinen Lähetetty (Arvio)

Tiistai 31. maaliskuuta 2015

Tutkimustietojen päivitykset

Viimeisin päivitys julkaistu (Arvio)

Tiistai 31. maaliskuuta 2015

Viimeisin lähetetty päivitys, joka täytti QC-kriteerit

Keskiviikko 25. maaliskuuta 2015

Viimeksi vahvistettu

Sunnuntai 1. maaliskuuta 2015

Lisää tietoa

Tähän tutkimukseen liittyvät termit

Lääke- ja laitetiedot, tutkimusasiakirjat

Tutkii yhdysvaltalaista FDA sääntelemää lääkevalmistetta

Ei

Tutkii yhdysvaltalaista FDA sääntelemää laitetuotetta

Ei

Yhdysvalloissa valmistettu ja sieltä viety tuote

Ei

Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .

Tilaa