Point-of-Care Bedside Lung Ultrasound Examination Advanced Trial Protocol (PoCBLUEPlus)

25 de março de 2015 atualizado por: Hong Liu, Nanjing Medical University

A Prospective, Multi-center, Open-label and Double-blind, Standard-controlled, Non-inferiority, Diagnostic Study of Lung Ultrasound for Management of Mechanical Ventilation in Neonatal Acute Respiratory Distress Syndrome

The purpose of this study was to evaluate the availability and diagnostic accuracy of point-of-care bedside lung ultrasound examination in management of mechanical ventilation in neonatal acute respiratory distress syndrome.

Visão geral do estudo

Descrição detalhada

Neonatal acute respiratory distress syndrome (ARDS) is a critical condition requiring dynamic evaluation and interventions. Point-of-care bedside lung ultrasound examination (PoC-BLUE) is a noninvasive, readily available imaging modality that can complement physical and clinical evaluation.

At any time, most neonates and infants with ARDS in medical intensive care units (ICUs) require mechanical ventilation, making it one of the most frequently used critical care technologies. However, difficulties with regard to the accurate diagnosis of ARDS before administration of mechanical ventilation, dynamic monitoring of treatment effects during administration of mechanical ventilation, and decision-making of timing in weaning from mechanical ventilation, are often encountered in the majority neonates and infants who require mechanical ventilation.

Hence, techniques that expedite and advance the knowledge of the administration of mechanical ventilation should have an important clinical significance in the diagnosis, treatment and prognosis of ARDS.

Preliminary researches have suggested that BLUE has a high diagnostic accuracy in patients with acute respiratory failure, and has the potential to quantify the rate and degree of diaphragm thinning during mechanical ventilation, which may be useful to predict extubation success or failure during either spontaneous breathing (SB) or pressure support (PS) trials.

Unfortunately, few studies focus on the availability of PoC-BLUE in management of mechanical ventilation in neonatal acute respiratory distress syndrome. Also, they call into question the possible association of the demographic and clinical confounders with the diagnostic accuracy of PoC-BLUE for diagnosis, monitoring and prognosis of ARDS in the whole process of mechanical ventilation.

Given that a considerable need for a timely and dynamic diagnosis of severe condition and therapy evaluation during mechanical ventilation has been triggered to integrate the currently available bulk of knowledge and information, the objective of this study is to investigate the availability and diagnostic accuracy of PoC-BLUE Plus protocol in management of mechanical ventilation in ARDS.

Tipo de estudo

Intervencional

Inscrição (Real)

1000

Estágio

  • Não aplicável

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

1 dia a 1 mês (Filho)

Aceita Voluntários Saudáveis

Não

Gêneros Elegíveis para o Estudo

Tudo

Descrição

Inclusion Criteria:

  • All infants who present to the ICU with respiratory symptoms suspicious for ARDS, according to Pediatric Acute Respiratory Distress Syndrome: Consensus Recommendations From the Pediatric Acute Lung Injury Consensus Conference, which is proposed by The Pediatric Acute Lung Injury Consensus Conference Group.
  • In whom the treating Collaborative Review Groups of Poc-BLUE-Plus protocol believe would benefit from diagnostic imaging.

Exclusion Criteria:

  • Infants who arrive at the ICU with a previously performed chest radiography
  • Unstable infants with life-threatening injuries who require ongoing resuscitation

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

  • Finalidade Principal: Diagnóstico
  • Alocação: Randomizado
  • Modelo Intervencional: Atribuição Paralela
  • Mascaramento: Dobro

Armas e Intervenções

Grupo de Participantes / Braço
Intervenção / Tratamento
Experimental: Lung Ultrasound
In infants allocated to this arm Lung ultrasound for detection of ARDS will be performed before chest radiography.
Lung ultrasound evaluation is performed after clinical assessment and before chest radiography
Outros nomes:
  • Bedside Ultrasonography System
Comparador Ativo: Chest Radiography
In infants allocated to this arm chest radiography will be performed for the detection of indirect signs of ARDS without ultrasound evaluation.
Chest Radiography is performed after clinical evaluation without using ultrasound assessment.
Outros nomes:
  • Chest X-ray System

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
Accuracy of Lung Ultrasound in Neonatal ARDS
Prazo: Accuracy will be measured at the end of clinical evaluation in the ICU, an expected average of 4 days
Accuracy of lung ultrasound and chest radiography will be measured using as gold standard the independent evaluation of the entire medical records by two expert emergency physicians blinded to the lung ultrasound results and radiographic reports (digitalized chest radiography images will be available).
Accuracy will be measured at the end of clinical evaluation in the ICU, an expected average of 4 days

Medidas de resultados secundários

Medida de resultado
Descrição da medida
Prazo
Accuracy of Lung Ultrasound in the Ventilator-Associated Pneumonia
Prazo: Accuracy will be measured at the end of clinical evaluation in the ICU, an expected average of 4 days
Accuracy of lung ultrasound and chest radiography will be measured using as gold standard the independent evaluation of the entire medical records by two expert emergency physicians blinded to the lung ultrasound results and radiographic reports (digitalized chest radiography images will be available).
Accuracy will be measured at the end of clinical evaluation in the ICU, an expected average of 4 days
Accuracy of Lung Ultrasound in the Weaning of Ventilatory Support
Prazo: Accuracy will be measured at the end of clinical evaluation in the ICU, an expected average of 4 days
Accuracy of lung ultrasound and chest radiography will be measured using as gold standard the independent evaluation of the entire medical records by two expert emergency physicians blinded to the lung ultrasound results and radiographic reports (digitalized chest radiography images will be available).
Accuracy will be measured at the end of clinical evaluation in the ICU, an expected average of 4 days

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Publicações e links úteis

A pessoa responsável por inserir informações sobre o estudo fornece voluntariamente essas publicações. Estes podem ser sobre qualquer coisa relacionada ao estudo.

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo

1 de março de 2014

Conclusão Primária (Real)

1 de março de 2015

Conclusão do estudo (Real)

1 de março de 2015

Datas de inscrição no estudo

Enviado pela primeira vez

22 de março de 2015

Enviado pela primeira vez que atendeu aos critérios de CQ

25 de março de 2015

Primeira postagem (Estimativa)

31 de março de 2015

Atualizações de registro de estudo

Última Atualização Postada (Estimativa)

31 de março de 2015

Última atualização enviada que atendeu aos critérios de controle de qualidade

25 de março de 2015

Última verificação

1 de março de 2015

Mais Informações

Termos relacionados a este estudo

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Não

produto fabricado e exportado dos EUA

Não

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .

Se inscrever