Diese Seite wurde automatisch übersetzt und die Genauigkeit der Übersetzung wird nicht garantiert. Bitte wende dich an die englische Version für einen Quelltext.

Point-of-Care Bedside Lung Ultrasound Examination Advanced Trial Protocol (PoCBLUEPlus)

25. März 2015 aktualisiert von: Hong Liu, Nanjing Medical University

A Prospective, Multi-center, Open-label and Double-blind, Standard-controlled, Non-inferiority, Diagnostic Study of Lung Ultrasound for Management of Mechanical Ventilation in Neonatal Acute Respiratory Distress Syndrome

The purpose of this study was to evaluate the availability and diagnostic accuracy of point-of-care bedside lung ultrasound examination in management of mechanical ventilation in neonatal acute respiratory distress syndrome.

Studienübersicht

Status

Abgeschlossen

Bedingungen

Detaillierte Beschreibung

Neonatal acute respiratory distress syndrome (ARDS) is a critical condition requiring dynamic evaluation and interventions. Point-of-care bedside lung ultrasound examination (PoC-BLUE) is a noninvasive, readily available imaging modality that can complement physical and clinical evaluation.

At any time, most neonates and infants with ARDS in medical intensive care units (ICUs) require mechanical ventilation, making it one of the most frequently used critical care technologies. However, difficulties with regard to the accurate diagnosis of ARDS before administration of mechanical ventilation, dynamic monitoring of treatment effects during administration of mechanical ventilation, and decision-making of timing in weaning from mechanical ventilation, are often encountered in the majority neonates and infants who require mechanical ventilation.

Hence, techniques that expedite and advance the knowledge of the administration of mechanical ventilation should have an important clinical significance in the diagnosis, treatment and prognosis of ARDS.

Preliminary researches have suggested that BLUE has a high diagnostic accuracy in patients with acute respiratory failure, and has the potential to quantify the rate and degree of diaphragm thinning during mechanical ventilation, which may be useful to predict extubation success or failure during either spontaneous breathing (SB) or pressure support (PS) trials.

Unfortunately, few studies focus on the availability of PoC-BLUE in management of mechanical ventilation in neonatal acute respiratory distress syndrome. Also, they call into question the possible association of the demographic and clinical confounders with the diagnostic accuracy of PoC-BLUE for diagnosis, monitoring and prognosis of ARDS in the whole process of mechanical ventilation.

Given that a considerable need for a timely and dynamic diagnosis of severe condition and therapy evaluation during mechanical ventilation has been triggered to integrate the currently available bulk of knowledge and information, the objective of this study is to investigate the availability and diagnostic accuracy of PoC-BLUE Plus protocol in management of mechanical ventilation in ARDS.

Studientyp

Interventionell

Einschreibung (Tatsächlich)

1000

Phase

  • Unzutreffend

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

1 Tag bis 1 Monat (Kind)

Akzeptiert gesunde Freiwillige

Nein

Studienberechtigte Geschlechter

Alle

Beschreibung

Inclusion Criteria:

  • All infants who present to the ICU with respiratory symptoms suspicious for ARDS, according to Pediatric Acute Respiratory Distress Syndrome: Consensus Recommendations From the Pediatric Acute Lung Injury Consensus Conference, which is proposed by The Pediatric Acute Lung Injury Consensus Conference Group.
  • In whom the treating Collaborative Review Groups of Poc-BLUE-Plus protocol believe would benefit from diagnostic imaging.

Exclusion Criteria:

  • Infants who arrive at the ICU with a previously performed chest radiography
  • Unstable infants with life-threatening injuries who require ongoing resuscitation

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

  • Hauptzweck: Diagnose
  • Zuteilung: Zufällig
  • Interventionsmodell: Parallele Zuordnung
  • Maskierung: Doppelt

Waffen und Interventionen

Teilnehmergruppe / Arm
Intervention / Behandlung
Experimental: Lung Ultrasound
In infants allocated to this arm Lung ultrasound for detection of ARDS will be performed before chest radiography.
Lung ultrasound evaluation is performed after clinical assessment and before chest radiography
Andere Namen:
  • Bedside Ultrasonography System
Aktiver Komparator: Chest Radiography
In infants allocated to this arm chest radiography will be performed for the detection of indirect signs of ARDS without ultrasound evaluation.
Chest Radiography is performed after clinical evaluation without using ultrasound assessment.
Andere Namen:
  • Chest X-ray System

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Accuracy of Lung Ultrasound in Neonatal ARDS
Zeitfenster: Accuracy will be measured at the end of clinical evaluation in the ICU, an expected average of 4 days
Accuracy of lung ultrasound and chest radiography will be measured using as gold standard the independent evaluation of the entire medical records by two expert emergency physicians blinded to the lung ultrasound results and radiographic reports (digitalized chest radiography images will be available).
Accuracy will be measured at the end of clinical evaluation in the ICU, an expected average of 4 days

Sekundäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Accuracy of Lung Ultrasound in the Ventilator-Associated Pneumonia
Zeitfenster: Accuracy will be measured at the end of clinical evaluation in the ICU, an expected average of 4 days
Accuracy of lung ultrasound and chest radiography will be measured using as gold standard the independent evaluation of the entire medical records by two expert emergency physicians blinded to the lung ultrasound results and radiographic reports (digitalized chest radiography images will be available).
Accuracy will be measured at the end of clinical evaluation in the ICU, an expected average of 4 days
Accuracy of Lung Ultrasound in the Weaning of Ventilatory Support
Zeitfenster: Accuracy will be measured at the end of clinical evaluation in the ICU, an expected average of 4 days
Accuracy of lung ultrasound and chest radiography will be measured using as gold standard the independent evaluation of the entire medical records by two expert emergency physicians blinded to the lung ultrasound results and radiographic reports (digitalized chest radiography images will be available).
Accuracy will be measured at the end of clinical evaluation in the ICU, an expected average of 4 days

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Publikationen und hilfreiche Links

Die Bereitstellung dieser Publikationen erfolgt freiwillig durch die für die Eingabe von Informationen über die Studie verantwortliche Person. Diese können sich auf alles beziehen, was mit dem Studium zu tun hat.

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn

1. März 2014

Primärer Abschluss (Tatsächlich)

1. März 2015

Studienabschluss (Tatsächlich)

1. März 2015

Studienanmeldedaten

Zuerst eingereicht

22. März 2015

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

25. März 2015

Zuerst gepostet (Schätzen)

31. März 2015

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Schätzen)

31. März 2015

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

25. März 2015

Zuletzt verifiziert

1. März 2015

Mehr Informationen

Begriffe im Zusammenhang mit dieser Studie

Arzneimittel- und Geräteinformationen, Studienunterlagen

Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt

Nein

Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt

Nein

Produkt, das in den USA hergestellt und aus den USA exportiert wird

Nein

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .