Tämä sivu käännettiin automaattisesti, eikä käännösten tarkkuutta voida taata. Katso englanninkielinen versio lähdetekstiä varten.

Measuring Blood Vessel Density in the Optic Nerve of Multiple Sclerosis Patients With OCTA

maanantai 1. kesäkuuta 2026 päivittänyt: Sarah Abdul Fattah Saad, Fayoum University

Quantitative OCT Angiography Differences in Optic Nerve Vascular Density in Multiple Sclerosis: A Case-Control Study

The goal of this observational study is to learn about the effect of multiple sclerosis on the blood flow of the optic nerve of affected patients compared to normal subjects by OCTA. The main question it aims to answer is:

  1. Does MS change the blood flow in the optic nerve?
  2. If it does, can measuring this blood flow be used as a simple sign (a biomarker) to help doctors understand and manage MS?

We used a quick and painless eye scan called Optical Coherence Tomography Angiography (OCTA). This special scan takes detailed pictures of the blood vessels in the optic nerve without needing any injections. We performed this scan on two groups of people: one group with MS and one group without MS, and then compare the results.

In simple terms, why is this important? If we can show that MS affects the optic nerve blood vessels, it could give us a new, quick way to monitor the disease and see how it is progressing, just by doing a simple eye scan.

Tutkimuksen yleiskatsaus

Yksityiskohtainen kuvaus

The optic nerve is like the main cable that carries visual information from the eye to the brain. In Multiple Sclerosis (MS), the body's immune system mistakenly attacks the protective covering (called myelin) around nerve fibers, including those in the optic nerve. This often causes a condition called optic neuritis, which can lead to vision loss.

While we know MS damages the nerve fibers, we are now trying to understand how it affects the blood vessels that supply oxygen and nutrients to the optic nerve. Are these blood vessels damaged as well? Does reduced blood flow contribute to the nerve damage?

2. The Technology We Are Using

This study uses a advanced, non-invasive imaging technology called Optical Coherence Tomography Angiography (OCTA).

What it does: The OCTA machine uses a safe, dim light beam to scan the optic nerve and macula. It works like a microscopic radar for blood vessels, allowing us to create very detailed, high-resolution 3D maps of the blood flow in the retina and optic nerve without any needles or injections.

What we measure: From these maps, we can quantitatively analyze the vessel density which is a percentage that tells us how much of a specific area is filled with functioning blood vessels. We will focus this measurement on the Radial Peripapillary Capillaries, which are the blood vessels that directly supply the optic nerve head.

3. The Purpose and Potential Impact of This Research

The main goal of this study is to determine if the blood vessel density in the optic nerve is a reliable biological marker (or biomarker) for MS.

A biomarker is an objective, measurable sign of a medical condition. If we can prove that changes in optic nerve blood flow are a consistent marker of MS, it could provide us with:

A new tool to help understand the disease activity in an individual.

A quick and painless way to potentially monitor how the disease is changing over time and whether treatments are effectively protecting the nervous system.

By comparing these detailed OCTA measurements between participants with and without MS, we hope to better understand the role of blood flow in the disease and contribute to improved future care for people living with MS.

Opintotyyppi

Havainnollistava

Ilmoittautuminen (Todellinen)

54

Yhteystiedot ja paikat

Tässä osiossa on tutkimuksen suorittajien yhteystiedot ja tiedot siitä, missä tämä tutkimus suoritetaan.

Opiskelupaikat

    • Faiyum Governorate
      • Al Fayyum, Faiyum Governorate, Egypti, 63514
        • Fayoum University hospital

Osallistumiskriteerit

Tutkijat etsivät ihmisiä, jotka sopivat tiettyyn kuvaukseen, jota kutsutaan kelpoisuuskriteereiksi. Joitakin esimerkkejä näistä kriteereistä ovat henkilön yleinen terveydentila tai aiemmat hoidot.

Kelpoisuusvaatimukset

Opintokelpoiset iät

  • Lapsi
  • Aikuinen
  • Vanhempi Aikuinen

Hyväksyy terveitä vapaaehtoisia

Joo

Näytteenottomenetelmä

Ei-todennäköisyysnäyte

Tutkimusväestö

This case-control study enrolled two groups: group 1; 26 adults with a clinically definite diagnosis of Multiple Sclerosis (Cases) and group 2; 28 age- and sex-matched healthy adults with no history of neurological or significant ocular disease (Controls).

Kuvaus

Inclusion Criteria:

  • group 1; patients with multiple sclerosis with optic neuritis.
  • group 2; normal healthy age matched controls

Exclusion Criteria:

  • Other optic nerve diseases as glaucoma, papilledema or conginetal anomalies.
  • Other macular diseases as AMD, CSR, scars …
  • Errors of refraction outside +4 and -6 D range.
  • Media opacity as cataracts or corneal opacities that may interfere with the quality of scans.
  • Signal strength index less than 4\10.

Opintosuunnitelma

Tässä osiossa on tietoja tutkimussuunnitelmasta, mukaan lukien kuinka tutkimus on suunniteltu ja mitä tutkimuksella mitataan.

Miten tutkimus on suunniteltu?

Suunnittelun yksityiskohdat

Kohortit ja interventiot

Ryhmä/Kohortti
Interventio / Hoito
Multiple Sclerosis (MS) Cohort
26 eyes of patients with clinically definite MS
optic nerve head analysis as regards the vessel density and retinal nerve fiber layer thickness and ganglion cell complex analysis as regards thickness and focal loss volume and global loss volume.
Healthy Control Cohort
28 eyes of age- and sex-matched normal subjects
optic nerve head analysis as regards the vessel density and retinal nerve fiber layer thickness and ganglion cell complex analysis as regards thickness and focal loss volume and global loss volume.

Mitä tutkimuksessa mitataan?

Ensisijaiset tulostoimenpiteet

Tulosmittaus
Toimenpiteen kuvaus
Aikaikkuna
vessel density of the optic nerve head and peripapillary region measured by OCTA
Aikaikkuna: Baseline
Difference in microvascular vessel density, as measured by Optical Coherence Tomography Angiography (OCTA), in the optic nerve head and peripapillary region between patients with Multiple Sclerosis and healthy controls. Analysis will include the whole disc area, inside the disc, and individual quadrants.
Baseline

Toissijaiset tulostoimenpiteet

Tulosmittaus
Toimenpiteen kuvaus
Aikaikkuna
RNFL thickness
Aikaikkuna: Baseline
Retinal Nerve Fiber Layer (RNFL) thickness, measured in micrometers, for the superior and inferior hemispheres of the optic nerve head.
Baseline
GCC thickness
Aikaikkuna: Baseline
The thickness of the macular Ganglion Cell Complex (GCC) was measured in micrometers for the superior and inferior hemispheres. These measurements were then analyzed by the device's proprietary software to calculate the Focal Loss Volume (FLV) and Global Loss Volume (GLV) indices.
Baseline

Yhteistyökumppanit ja tutkijat

Täältä löydät tähän tutkimukseen osallistuvat ihmiset ja organisaatiot.

Opintojen ennätyspäivät

Nämä päivämäärät seuraavat ClinicalTrials.gov-sivustolle lähetettyjen tutkimustietueiden ja yhteenvetojen edistymistä. National Library of Medicine (NLM) tarkistaa tutkimustiedot ja raportoidut tulokset varmistaakseen, että ne täyttävät tietyt laadunvalvontastandardit, ennen kuin ne julkaistaan ​​julkisella verkkosivustolla.

Opi tärkeimmät päivämäärät

Opiskelun aloitus (Todellinen)

Sunnuntai 5. tammikuuta 2025

Ensisijainen valmistuminen (Todellinen)

Sunnuntai 3. elokuuta 2025

Opintojen valmistuminen (Todellinen)

Sunnuntai 3. elokuuta 2025

Opintoihin ilmoittautumispäivät

Ensimmäinen lähetetty

Perjantai 26. syyskuuta 2025

Ensimmäinen toimitettu, joka täytti QC-kriteerit

Maanantai 1. kesäkuuta 2026

Ensimmäinen Lähetetty (Todellinen)

Perjantai 5. kesäkuuta 2026

Tutkimustietojen päivitykset

Viimeisin päivitys julkaistu (Todellinen)

Perjantai 5. kesäkuuta 2026

Viimeisin lähetetty päivitys, joka täytti QC-kriteerit

Maanantai 1. kesäkuuta 2026

Viimeksi vahvistettu

Maanantai 1. syyskuuta 2025

Lisää tietoa

Tähän tutkimukseen liittyvät termit

Yksittäisten osallistujien tietojen suunnitelma (IPD)

Aiotko jakaa yksittäisten osallistujien tietoja (IPD)?

PÄÄTTÄMÄTÖN

Lääke- ja laitetiedot, tutkimusasiakirjat

Tutkii yhdysvaltalaista FDA sääntelemää lääkevalmistetta

Ei

Tutkii yhdysvaltalaista FDA sääntelemää laitetuotetta

Joo

Yhdysvalloissa valmistettu ja sieltä viety tuote

Joo

Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .

Tilaa