Deze pagina is automatisch vertaald en de nauwkeurigheid van de vertaling kan niet worden gegarandeerd. Raadpleeg de Engelse versie voor een brontekst.

Measuring Blood Vessel Density in the Optic Nerve of Multiple Sclerosis Patients With OCTA

1 juni 2026 bijgewerkt door: Sarah Abdul Fattah Saad, Fayoum University

Quantitative OCT Angiography Differences in Optic Nerve Vascular Density in Multiple Sclerosis: A Case-Control Study

The goal of this observational study is to learn about the effect of multiple sclerosis on the blood flow of the optic nerve of affected patients compared to normal subjects by OCTA. The main question it aims to answer is:

  1. Does MS change the blood flow in the optic nerve?
  2. If it does, can measuring this blood flow be used as a simple sign (a biomarker) to help doctors understand and manage MS?

We used a quick and painless eye scan called Optical Coherence Tomography Angiography (OCTA). This special scan takes detailed pictures of the blood vessels in the optic nerve without needing any injections. We performed this scan on two groups of people: one group with MS and one group without MS, and then compare the results.

In simple terms, why is this important? If we can show that MS affects the optic nerve blood vessels, it could give us a new, quick way to monitor the disease and see how it is progressing, just by doing a simple eye scan.

Studie Overzicht

Toestand

Voltooid

Gedetailleerde beschrijving

The optic nerve is like the main cable that carries visual information from the eye to the brain. In Multiple Sclerosis (MS), the body's immune system mistakenly attacks the protective covering (called myelin) around nerve fibers, including those in the optic nerve. This often causes a condition called optic neuritis, which can lead to vision loss.

While we know MS damages the nerve fibers, we are now trying to understand how it affects the blood vessels that supply oxygen and nutrients to the optic nerve. Are these blood vessels damaged as well? Does reduced blood flow contribute to the nerve damage?

2. The Technology We Are Using

This study uses a advanced, non-invasive imaging technology called Optical Coherence Tomography Angiography (OCTA).

What it does: The OCTA machine uses a safe, dim light beam to scan the optic nerve and macula. It works like a microscopic radar for blood vessels, allowing us to create very detailed, high-resolution 3D maps of the blood flow in the retina and optic nerve without any needles or injections.

What we measure: From these maps, we can quantitatively analyze the vessel density which is a percentage that tells us how much of a specific area is filled with functioning blood vessels. We will focus this measurement on the Radial Peripapillary Capillaries, which are the blood vessels that directly supply the optic nerve head.

3. The Purpose and Potential Impact of This Research

The main goal of this study is to determine if the blood vessel density in the optic nerve is a reliable biological marker (or biomarker) for MS.

A biomarker is an objective, measurable sign of a medical condition. If we can prove that changes in optic nerve blood flow are a consistent marker of MS, it could provide us with:

A new tool to help understand the disease activity in an individual.

A quick and painless way to potentially monitor how the disease is changing over time and whether treatments are effectively protecting the nervous system.

By comparing these detailed OCTA measurements between participants with and without MS, we hope to better understand the role of blood flow in the disease and contribute to improved future care for people living with MS.

Studietype

Observationeel

Inschrijving (Werkelijk)

54

Contacten en locaties

In dit gedeelte vindt u de contactgegevens van degenen die het onderzoek uitvoeren en informatie over waar dit onderzoek wordt uitgevoerd.

Studie Locaties

    • Faiyum Governorate
      • Al Fayyum, Faiyum Governorate, Egypte, 63514
        • Fayoum University hospital

Deelname Criteria

Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.

Geschiktheidscriteria

Leeftijden die in aanmerking komen voor studie

  • Kind
  • Volwassen
  • Oudere volwassene

Accepteert gezonde vrijwilligers

Ja

Bemonsteringsmethode

Niet-waarschijnlijkheidssteekproef

Studie Bevolking

This case-control study enrolled two groups: group 1; 26 adults with a clinically definite diagnosis of Multiple Sclerosis (Cases) and group 2; 28 age- and sex-matched healthy adults with no history of neurological or significant ocular disease (Controls).

Beschrijving

Inclusion Criteria:

  • group 1; patients with multiple sclerosis with optic neuritis.
  • group 2; normal healthy age matched controls

Exclusion Criteria:

  • Other optic nerve diseases as glaucoma, papilledema or conginetal anomalies.
  • Other macular diseases as AMD, CSR, scars …
  • Errors of refraction outside +4 and -6 D range.
  • Media opacity as cataracts or corneal opacities that may interfere with the quality of scans.
  • Signal strength index less than 4\10.

Studie plan

Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.

Hoe is de studie opgezet?

Ontwerpdetails

Cohorten en interventies

Groep / Cohort
Interventie / Behandeling
Multiple Sclerosis (MS) Cohort
26 eyes of patients with clinically definite MS
optic nerve head analysis as regards the vessel density and retinal nerve fiber layer thickness and ganglion cell complex analysis as regards thickness and focal loss volume and global loss volume.
Healthy Control Cohort
28 eyes of age- and sex-matched normal subjects
optic nerve head analysis as regards the vessel density and retinal nerve fiber layer thickness and ganglion cell complex analysis as regards thickness and focal loss volume and global loss volume.

Wat meet het onderzoek?

Primaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
vessel density of the optic nerve head and peripapillary region measured by OCTA
Tijdsspanne: Baseline
Difference in microvascular vessel density, as measured by Optical Coherence Tomography Angiography (OCTA), in the optic nerve head and peripapillary region between patients with Multiple Sclerosis and healthy controls. Analysis will include the whole disc area, inside the disc, and individual quadrants.
Baseline

Secundaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
RNFL thickness
Tijdsspanne: Baseline
Retinal Nerve Fiber Layer (RNFL) thickness, measured in micrometers, for the superior and inferior hemispheres of the optic nerve head.
Baseline
GCC thickness
Tijdsspanne: Baseline
The thickness of the macular Ganglion Cell Complex (GCC) was measured in micrometers for the superior and inferior hemispheres. These measurements were then analyzed by the device's proprietary software to calculate the Focal Loss Volume (FLV) and Global Loss Volume (GLV) indices.
Baseline

Medewerkers en onderzoekers

Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.

Studie record data

Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.

Bestudeer belangrijke data

Studie start (Werkelijk)

5 januari 2025

Primaire voltooiing (Werkelijk)

3 augustus 2025

Studie voltooiing (Werkelijk)

3 augustus 2025

Studieregistratiedata

Eerst ingediend

26 september 2025

Eerst ingediend dat voldeed aan de QC-criteria

1 juni 2026

Eerst geplaatst (Werkelijk)

5 juni 2026

Updates van studierecords

Laatste update geplaatst (Werkelijk)

5 juni 2026

Laatste update ingediend die voldeed aan QC-criteria

1 juni 2026

Laatst geverifieerd

1 september 2025

Meer informatie

Termen gerelateerd aan deze studie

Plan Individuele Deelnemersgegevens (IPD)

Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?

ONBESLIST

Informatie over medicijnen en apparaten, studiedocumenten

Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel

Nee

Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct

Ja

product vervaardigd in en geëxporteerd uit de V.S.

Ja

Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .

Abonneren