Denne siden ble automatisk oversatt og nøyaktigheten av oversettelsen er ikke garantert. Vennligst referer til engelsk versjon for en kildetekst.

Measuring Blood Vessel Density in the Optic Nerve of Multiple Sclerosis Patients With OCTA

1. juni 2026 oppdatert av: Sarah Abdul Fattah Saad, Fayoum University

Quantitative OCT Angiography Differences in Optic Nerve Vascular Density in Multiple Sclerosis: A Case-Control Study

The goal of this observational study is to learn about the effect of multiple sclerosis on the blood flow of the optic nerve of affected patients compared to normal subjects by OCTA. The main question it aims to answer is:

  1. Does MS change the blood flow in the optic nerve?
  2. If it does, can measuring this blood flow be used as a simple sign (a biomarker) to help doctors understand and manage MS?

We used a quick and painless eye scan called Optical Coherence Tomography Angiography (OCTA). This special scan takes detailed pictures of the blood vessels in the optic nerve without needing any injections. We performed this scan on two groups of people: one group with MS and one group without MS, and then compare the results.

In simple terms, why is this important? If we can show that MS affects the optic nerve blood vessels, it could give us a new, quick way to monitor the disease and see how it is progressing, just by doing a simple eye scan.

Studieoversikt

Status

Fullført

Detaljert beskrivelse

The optic nerve is like the main cable that carries visual information from the eye to the brain. In Multiple Sclerosis (MS), the body's immune system mistakenly attacks the protective covering (called myelin) around nerve fibers, including those in the optic nerve. This often causes a condition called optic neuritis, which can lead to vision loss.

While we know MS damages the nerve fibers, we are now trying to understand how it affects the blood vessels that supply oxygen and nutrients to the optic nerve. Are these blood vessels damaged as well? Does reduced blood flow contribute to the nerve damage?

2. The Technology We Are Using

This study uses a advanced, non-invasive imaging technology called Optical Coherence Tomography Angiography (OCTA).

What it does: The OCTA machine uses a safe, dim light beam to scan the optic nerve and macula. It works like a microscopic radar for blood vessels, allowing us to create very detailed, high-resolution 3D maps of the blood flow in the retina and optic nerve without any needles or injections.

What we measure: From these maps, we can quantitatively analyze the vessel density which is a percentage that tells us how much of a specific area is filled with functioning blood vessels. We will focus this measurement on the Radial Peripapillary Capillaries, which are the blood vessels that directly supply the optic nerve head.

3. The Purpose and Potential Impact of This Research

The main goal of this study is to determine if the blood vessel density in the optic nerve is a reliable biological marker (or biomarker) for MS.

A biomarker is an objective, measurable sign of a medical condition. If we can prove that changes in optic nerve blood flow are a consistent marker of MS, it could provide us with:

A new tool to help understand the disease activity in an individual.

A quick and painless way to potentially monitor how the disease is changing over time and whether treatments are effectively protecting the nervous system.

By comparing these detailed OCTA measurements between participants with and without MS, we hope to better understand the role of blood flow in the disease and contribute to improved future care for people living with MS.

Studietype

Observasjonsmessig

Registrering (Faktiske)

54

Kontakter og plasseringer

Denne delen inneholder kontaktinformasjon for de som utfører studien, og informasjon om hvor denne studien blir utført.

Studiesteder

    • Faiyum Governorate
      • Al Fayyum, Faiyum Governorate, Egypt, 63514
        • Fayoum University hospital

Deltakelseskriterier

Forskere ser etter personer som passer til en bestemt beskrivelse, kalt kvalifikasjonskriterier. Noen eksempler på disse kriteriene er en persons generelle helsetilstand eller tidligere behandlinger.

Kvalifikasjonskriterier

Alder som er kvalifisert for studier

  • Barn
  • Voksen
  • Eldre voksen

Tar imot friske frivillige

Ja

Prøvetakingsmetode

Ikke-sannsynlighetsprøve

Studiepopulasjon

This case-control study enrolled two groups: group 1; 26 adults with a clinically definite diagnosis of Multiple Sclerosis (Cases) and group 2; 28 age- and sex-matched healthy adults with no history of neurological or significant ocular disease (Controls).

Beskrivelse

Inclusion Criteria:

  • group 1; patients with multiple sclerosis with optic neuritis.
  • group 2; normal healthy age matched controls

Exclusion Criteria:

  • Other optic nerve diseases as glaucoma, papilledema or conginetal anomalies.
  • Other macular diseases as AMD, CSR, scars …
  • Errors of refraction outside +4 and -6 D range.
  • Media opacity as cataracts or corneal opacities that may interfere with the quality of scans.
  • Signal strength index less than 4\10.

Studieplan

Denne delen gir detaljer om studieplanen, inkludert hvordan studien er utformet og hva studien måler.

Hvordan er studiet utformet?

Designdetaljer

Kohorter og intervensjoner

Gruppe / Kohort
Intervensjon / Behandling
Multiple Sclerosis (MS) Cohort
26 eyes of patients with clinically definite MS
optic nerve head analysis as regards the vessel density and retinal nerve fiber layer thickness and ganglion cell complex analysis as regards thickness and focal loss volume and global loss volume.
Healthy Control Cohort
28 eyes of age- and sex-matched normal subjects
optic nerve head analysis as regards the vessel density and retinal nerve fiber layer thickness and ganglion cell complex analysis as regards thickness and focal loss volume and global loss volume.

Hva måler studien?

Primære resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
vessel density of the optic nerve head and peripapillary region measured by OCTA
Tidsramme: Baseline
Difference in microvascular vessel density, as measured by Optical Coherence Tomography Angiography (OCTA), in the optic nerve head and peripapillary region between patients with Multiple Sclerosis and healthy controls. Analysis will include the whole disc area, inside the disc, and individual quadrants.
Baseline

Sekundære resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
RNFL thickness
Tidsramme: Baseline
Retinal Nerve Fiber Layer (RNFL) thickness, measured in micrometers, for the superior and inferior hemispheres of the optic nerve head.
Baseline
GCC thickness
Tidsramme: Baseline
The thickness of the macular Ganglion Cell Complex (GCC) was measured in micrometers for the superior and inferior hemispheres. These measurements were then analyzed by the device's proprietary software to calculate the Focal Loss Volume (FLV) and Global Loss Volume (GLV) indices.
Baseline

Samarbeidspartnere og etterforskere

Det er her du vil finne personer og organisasjoner som er involvert i denne studien.

Studierekorddatoer

Disse datoene sporer fremdriften for innsending av studieposter og sammendragsresultater til ClinicalTrials.gov. Studieposter og rapporterte resultater gjennomgås av National Library of Medicine (NLM) for å sikre at de oppfyller spesifikke kvalitetskontrollstandarder før de legges ut på det offentlige nettstedet.

Studer hoveddatoer

Studiestart (Faktiske)

5. januar 2025

Primær fullføring (Faktiske)

3. august 2025

Studiet fullført (Faktiske)

3. august 2025

Datoer for studieregistrering

Først innsendt

26. september 2025

Først innsendt som oppfylte QC-kriteriene

1. juni 2026

Først lagt ut (Faktiske)

5. juni 2026

Oppdateringer av studieposter

Sist oppdatering lagt ut (Faktiske)

5. juni 2026

Siste oppdatering sendt inn som oppfylte QC-kriteriene

1. juni 2026

Sist bekreftet

1. september 2025

Mer informasjon

Begreper knyttet til denne studien

Plan for individuelle deltakerdata (IPD)

Planlegger du å dele individuelle deltakerdata (IPD)?

UBESLUTTE

Legemiddel- og utstyrsinformasjon, studiedokumenter

Studerer et amerikansk FDA-regulert medikamentprodukt

Nei

Studerer et amerikansk FDA-regulert enhetsprodukt

Ja

produkt produsert i og eksportert fra USA

Ja

Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .

Abonnere