Measuring Blood Vessel Density in the Optic Nerve of Multiple Sclerosis Patients With OCTA

1 июня 2026 г. обновлено: Sarah Abdul Fattah Saad, Fayoum University

Quantitative OCT Angiography Differences in Optic Nerve Vascular Density in Multiple Sclerosis: A Case-Control Study

The goal of this observational study is to learn about the effect of multiple sclerosis on the blood flow of the optic nerve of affected patients compared to normal subjects by OCTA. The main question it aims to answer is:

  1. Does MS change the blood flow in the optic nerve?
  2. If it does, can measuring this blood flow be used as a simple sign (a biomarker) to help doctors understand and manage MS?

We used a quick and painless eye scan called Optical Coherence Tomography Angiography (OCTA). This special scan takes detailed pictures of the blood vessels in the optic nerve without needing any injections. We performed this scan on two groups of people: one group with MS and one group without MS, and then compare the results.

In simple terms, why is this important? If we can show that MS affects the optic nerve blood vessels, it could give us a new, quick way to monitor the disease and see how it is progressing, just by doing a simple eye scan.

Обзор исследования

Статус

Завершенный

Подробное описание

The optic nerve is like the main cable that carries visual information from the eye to the brain. In Multiple Sclerosis (MS), the body's immune system mistakenly attacks the protective covering (called myelin) around nerve fibers, including those in the optic nerve. This often causes a condition called optic neuritis, which can lead to vision loss.

While we know MS damages the nerve fibers, we are now trying to understand how it affects the blood vessels that supply oxygen and nutrients to the optic nerve. Are these blood vessels damaged as well? Does reduced blood flow contribute to the nerve damage?

2. The Technology We Are Using

This study uses a advanced, non-invasive imaging technology called Optical Coherence Tomography Angiography (OCTA).

What it does: The OCTA machine uses a safe, dim light beam to scan the optic nerve and macula. It works like a microscopic radar for blood vessels, allowing us to create very detailed, high-resolution 3D maps of the blood flow in the retina and optic nerve without any needles or injections.

What we measure: From these maps, we can quantitatively analyze the vessel density which is a percentage that tells us how much of a specific area is filled with functioning blood vessels. We will focus this measurement on the Radial Peripapillary Capillaries, which are the blood vessels that directly supply the optic nerve head.

3. The Purpose and Potential Impact of This Research

The main goal of this study is to determine if the blood vessel density in the optic nerve is a reliable biological marker (or biomarker) for MS.

A biomarker is an objective, measurable sign of a medical condition. If we can prove that changes in optic nerve blood flow are a consistent marker of MS, it could provide us with:

A new tool to help understand the disease activity in an individual.

A quick and painless way to potentially monitor how the disease is changing over time and whether treatments are effectively protecting the nervous system.

By comparing these detailed OCTA measurements between participants with and without MS, we hope to better understand the role of blood flow in the disease and contribute to improved future care for people living with MS.

Тип исследования

Наблюдательный

Регистрация (Действительный)

54

Контакты и местонахождение

В этом разделе приведены контактные данные лиц, проводящих исследование, и информация о том, где проводится это исследование.

Места учебы

    • Faiyum Governorate
      • Al Fayyum, Faiyum Governorate, Египет, 63514
        • Fayoum University hospital

Критерии участия

Исследователи ищут людей, которые соответствуют определенному описанию, называемому критериям приемлемости. Некоторыми примерами этих критериев являются общее состояние здоровья человека или предшествующее лечение.

Критерии приемлемости

Возраст, подходящий для обучения

  • Ребенок
  • Взрослый
  • Пожилой взрослый

Принимает здоровых добровольцев

Да

Метод выборки

Невероятностная выборка

Исследуемая популяция

This case-control study enrolled two groups: group 1; 26 adults with a clinically definite diagnosis of Multiple Sclerosis (Cases) and group 2; 28 age- and sex-matched healthy adults with no history of neurological or significant ocular disease (Controls).

Описание

Inclusion Criteria:

  • group 1; patients with multiple sclerosis with optic neuritis.
  • group 2; normal healthy age matched controls

Exclusion Criteria:

  • Other optic nerve diseases as glaucoma, papilledema or conginetal anomalies.
  • Other macular diseases as AMD, CSR, scars …
  • Errors of refraction outside +4 and -6 D range.
  • Media opacity as cataracts or corneal opacities that may interfere with the quality of scans.
  • Signal strength index less than 4\10.

Учебный план

В этом разделе представлена ​​подробная информация о плане исследования, в том числе о том, как планируется исследование и что оно измеряет.

Как устроено исследование?

Детали дизайна

Когорты и вмешательства

Группа / когорта
Вмешательство/лечение
Multiple Sclerosis (MS) Cohort
26 eyes of patients with clinically definite MS
optic nerve head analysis as regards the vessel density and retinal nerve fiber layer thickness and ganglion cell complex analysis as regards thickness and focal loss volume and global loss volume.
Healthy Control Cohort
28 eyes of age- and sex-matched normal subjects
optic nerve head analysis as regards the vessel density and retinal nerve fiber layer thickness and ganglion cell complex analysis as regards thickness and focal loss volume and global loss volume.

Что измеряет исследование?

Первичные показатели результатов

Мера результата
Мера Описание
Временное ограничение
vessel density of the optic nerve head and peripapillary region measured by OCTA
Временное ограничение: Baseline
Difference in microvascular vessel density, as measured by Optical Coherence Tomography Angiography (OCTA), in the optic nerve head and peripapillary region between patients with Multiple Sclerosis and healthy controls. Analysis will include the whole disc area, inside the disc, and individual quadrants.
Baseline

Вторичные показатели результатов

Мера результата
Мера Описание
Временное ограничение
RNFL thickness
Временное ограничение: Baseline
Retinal Nerve Fiber Layer (RNFL) thickness, measured in micrometers, for the superior and inferior hemispheres of the optic nerve head.
Baseline
GCC thickness
Временное ограничение: Baseline
The thickness of the macular Ganglion Cell Complex (GCC) was measured in micrometers for the superior and inferior hemispheres. These measurements were then analyzed by the device's proprietary software to calculate the Focal Loss Volume (FLV) and Global Loss Volume (GLV) indices.
Baseline

Соавторы и исследователи

Здесь вы найдете людей и организации, участвующие в этом исследовании.

Спонсор

Даты записи исследования

Эти даты отслеживают ход отправки отчетов об исследованиях и сводных результатов на сайт ClinicalTrials.gov. Записи исследований и сообщаемые результаты проверяются Национальной медицинской библиотекой (NLM), чтобы убедиться, что они соответствуют определенным стандартам контроля качества, прежде чем публиковать их на общедоступном веб-сайте.

Изучение основных дат

Начало исследования (Действительный)

5 января 2025 г.

Первичное завершение (Действительный)

3 августа 2025 г.

Завершение исследования (Действительный)

3 августа 2025 г.

Даты регистрации исследования

Первый отправленный

26 сентября 2025 г.

Впервые представлено, что соответствует критериям контроля качества

1 июня 2026 г.

Первый опубликованный (Действительный)

5 июня 2026 г.

Обновления учебных записей

Последнее опубликованное обновление (Действительный)

5 июня 2026 г.

Последнее отправленное обновление, отвечающее критериям контроля качества

1 июня 2026 г.

Последняя проверка

1 сентября 2025 г.

Дополнительная информация

Термины, связанные с этим исследованием

Планирование данных отдельных участников (IPD)

Планируете делиться данными об отдельных участниках (IPD)?

НЕ РЕШЕНО

Информация о лекарствах и устройствах, исследовательские документы

Изучает лекарственный продукт, регулируемый FDA США.

Нет

Изучает продукт устройства, регулируемый Управлением по санитарному надзору за качеством пищевых продуктов и медикаментов США.

Да

продукт, произведенный в США и экспортированный из США.

Да

Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .

Подписаться