- ICH GCP
- Yhdysvaltain kliinisten tutkimusten rekisteri
- Kliininen tutkimus NCT07642115
The Use of Ultrasound to Assess the Airway Anatomy Regarding Pharyngeal Seal and Its Protective Role Throw a Chemical Test for Three Supraglottic Devices (ProSeal LMA, I-gel, and I-gel Plus) (LMA)
Ultrasonographic Mapping of the Pharyngeal Seal and Its Protective Role for Three Supraglottic Devices (ProSeal LMA, I-gel, and I-gel Plus)
The goal of this clinical trial is to to evaluate the sealing quality of three second-generation SADs (ProSeal LMA, i-gel, and i-gel Plus) using ultrasonography to measure the cross-sectional area (CSA) of sealing, Anterior-Posterior (AP) Diameter and Transverse (TV) Diameter ,percentage of effective sealing , presence of sealing gap and correlate these anatomical findings with oropharyngeal leak pressure (OLP), while simultaneously testing relevant safety features of regurgitation risk through salivary pH measurement.
The findings from this investigation may contribute to improved device selection and enhanced patient safety during procedures requiring supraglottic airway management.
Tutkimuksen yleiskatsaus
Tila
Interventio / Hoito
- Muut: evaluate the sealing quality (ProSeal LMA)using ultrasonography and a biochemical non invasive test to evaluate regurgitation
- Muut: evaluate the sealing quality of SGA device ( i-gel)using ultrasonography and a biochemical test for assessment of regurgitation
- Muut: evaluate the sealing quality of SGA device ( i-gel plus )using ultrasonography and a biochemical test for assessment of regurgitation
Opintotyyppi
Ilmoittautuminen (Arvioitu)
Vaihe
- Ei sovellettavissa
Yhteystiedot ja paikat
Opiskelupaikat
-
-
-
Cairo, Egypti
- Faculty of medicine ain shams university
-
-
Osallistumiskriteerit
Kelpoisuusvaatimukset
Opintokelpoiset iät
- Aikuinen
Hyväksyy terveitä vapaaehtoisia
Kuvaus
Inclusion Criteria:
- Age 18-55 years ASA physical status I or II, BMI 18-35 kg/m² Scheduled for elective surgery that requires around (2-3 hours) duration requiring general anesthesia with an SGAD.
Exclusion Criteria:
- History of gastroesophageal reflux disease (GERD) Known or anticipated difficult airway, pathology of the mouth/oropharynx/neck, risk of aspiration.
Pregnancy.
Opintosuunnitelma
Miten tutkimus on suunniteltu?
Suunnittelun yksityiskohdat
- Ensisijainen käyttötarkoitus: Seulonta
- Jako: Satunnaistettu
- Inventiomalli: Rinnakkaistehtävä
- Naamiointi: Ei mitään (avoin tarra)
Aseet ja interventiot
Osallistujaryhmä / Arm |
Interventio / Hoito |
|---|---|
|
Active Comparator: Group P: ProSeal.
Using computer-generated random numbers to assign patients to one of the three device groups: First group is Group P: ProSeal |
This multimodal approach, combining ultrasound assessment of sealing quality with biochemical monitoring of regurgitation, may provide valuable insights into the comparative effectiveness of different SAD designs and ensure patient safety.
Muut nimet:
|
|
Active Comparator: Group I: i-gel.
Using computer-generated random numbers to assign patients to one of the three device groups: Second group Group I: i-gel. |
This multimodal approach, combining ultrasound assessment of sealing quality with biochemical monitoring of regurgitation, may provide valuable insights into the comparative effectiveness of different SAD designs and ensure patient safety.
Muut nimet:
|
|
Active Comparator: Group I+: i-gel Plus.
Using computer-generated random numbers to assign patients to one of the three device groups: Third group Group I+: i-gel Plus. |
This multimodal approach, combining ultrasound assessment of sealing quality with biochemical monitoring of regurgitation, may provide valuable insights into the comparative effectiveness of different SAD designs and ensure patient safety.
Muut nimet:
|
Mitä tutkimuksessa mitataan?
Ensisijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
Ultrasound mapping of sealing efficacy with correlation to OLP
Aikaikkuna: The primary outcome will be assessed throw the operation time from 2 hours to 4 hours time frame to obtain this outcome.
|
evaluate the sealing quality of three second-generation SADs (ProSeal LMA, i-gel, and i-gel Plus) using ultrasonography to measure the cross-sectional area (CSA) of sealing, Anterior-Posterior (AP) Diameter and Transverse (TV) Diameter ,percentage of effective sealing , presence of sealing gap and correlate these anatomical findings with oropharyngeal leak pressure (OLP).
|
The primary outcome will be assessed throw the operation time from 2 hours to 4 hours time frame to obtain this outcome.
|
Toissijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
Assessment for Regurgitation and microaspiration
Aikaikkuna: Throw operative time a base line and at the end of operation before emergence of anathesia.
|
Post insertion of device, place a Salivary Collection Device in the oropharynx via the drainage channel for 5 minutes to collect secretion. Post-operatively A sample of saliva will be collected by the anesthesiologist, and the sample PH will be checked. |
Throw operative time a base line and at the end of operation before emergence of anathesia.
|
Yhteistyökumppanit ja tutkijat
Sponsori
Julkaisuja ja hyödyllisiä linkkejä
Yleiset julkaisut
- Ahn, J. H., Jeong, J. S., Kang, S. H., Yeon, J. E., Cho, E. A., Choi, G. S., ... & Kim, G. S. (2021). Comparison of intragastric pressure between endotracheal tube and supraglottic airway devices in laparoscopic hepatectomy: A randomized, controlled, non-inferiority study. Medicine, 100(24), e26287. Jung, Y., Jung, S., Yu, S., Jeong, M. A., & Kim, C. L. (2024). Gastric distension and atelectasis after using a supraglottic airway-A case report. Anesthesia and Pain Medicine, 19(3), 261-265. O'Riordan, C., Van De Ven, P., Nelson, J., McCreesh, K., & Clifford, A. (2016). Reliability of a measurement method for the cross-sectional area of the longus colli using real-time ultrasound imaging. Ultrasound, 24(3), 154-162. Solanki, S. L., Johnson, J. E., & Samantaray, A. (2020). Supraglottic airway devices: Placement and pharyngeal seal matters!. Indian Journal of Anaesthesia, 64(8), 649-652. Werner, J., Klementova, O., Bruthans, J., Macoun, J., Gaszynski, T., Henlin, T., ... & Michalek, P. (2024). Evaluation of the i-gel® Plus supraglottic airway device in elective surgery: a prospective international multicentre study. Anaesthesia, 79(12), 1284-1291. Zhang, K., Zhou, M., Zou, Z., Zhu, C., & Jiang, R. (2024). Supraglottic airway devices: a powerful strategy in airway management. American journal of cancer research, 14(1), 16., ISO 690.
Opintojen ennätyspäivät
Opi tärkeimmät päivämäärät
Opiskelun aloitus (Todellinen)
Ensisijainen valmistuminen (Arvioitu)
Opintojen valmistuminen (Arvioitu)
Opintoihin ilmoittautumispäivät
Ensimmäinen lähetetty
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen Lähetetty (Todellinen)
Tutkimustietojen päivitykset
Viimeisin päivitys julkaistu (Todellinen)
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeksi vahvistettu
Lisää tietoa
Tähän tutkimukseen liittyvät termit
Avainsanat
Muita asiaankuuluvia MeSH-ehtoja
Muut tutkimustunnusnumerot
- FMASU317/2025
Yksittäisten osallistujien tietojen suunnitelma (IPD)
Aiotko jakaa yksittäisten osallistujien tietoja (IPD)?
Lääke- ja laitetiedot, tutkimusasiakirjat
Tutkii yhdysvaltalaista FDA sääntelemää lääkevalmistetta
Tutkii yhdysvaltalaista FDA sääntelemää laitetuotetta
Yhdysvalloissa valmistettu ja sieltä viety tuote
Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .