- ICH GCP
- Amerikanska kliniska prövningsregistret
- Klinisk prövning NCT07642115
The Use of Ultrasound to Assess the Airway Anatomy Regarding Pharyngeal Seal and Its Protective Role Throw a Chemical Test for Three Supraglottic Devices (ProSeal LMA, I-gel, and I-gel Plus) (LMA)
Ultrasonographic Mapping of the Pharyngeal Seal and Its Protective Role for Three Supraglottic Devices (ProSeal LMA, I-gel, and I-gel Plus)
The goal of this clinical trial is to to evaluate the sealing quality of three second-generation SADs (ProSeal LMA, i-gel, and i-gel Plus) using ultrasonography to measure the cross-sectional area (CSA) of sealing, Anterior-Posterior (AP) Diameter and Transverse (TV) Diameter ,percentage of effective sealing , presence of sealing gap and correlate these anatomical findings with oropharyngeal leak pressure (OLP), while simultaneously testing relevant safety features of regurgitation risk through salivary pH measurement.
The findings from this investigation may contribute to improved device selection and enhanced patient safety during procedures requiring supraglottic airway management.
Studieöversikt
Status
Intervention / Behandling
- Övrig: evaluate the sealing quality (ProSeal LMA)using ultrasonography and a biochemical non invasive test to evaluate regurgitation
- Övrig: evaluate the sealing quality of SGA device ( i-gel)using ultrasonography and a biochemical test for assessment of regurgitation
- Övrig: evaluate the sealing quality of SGA device ( i-gel plus )using ultrasonography and a biochemical test for assessment of regurgitation
Studietyp
Inskrivning (Beräknad)
Fas
- Inte tillämpbar
Kontakter och platser
Studieorter
-
-
-
Cairo, Egypten
- Faculty of medicine ain shams university
-
-
Deltagandekriterier
Urvalskriterier
Åldrar som är berättigade till studier
- Vuxen
Tar emot friska volontärer
Beskrivning
Inclusion Criteria:
- Age 18-55 years ASA physical status I or II, BMI 18-35 kg/m² Scheduled for elective surgery that requires around (2-3 hours) duration requiring general anesthesia with an SGAD.
Exclusion Criteria:
- History of gastroesophageal reflux disease (GERD) Known or anticipated difficult airway, pathology of the mouth/oropharynx/neck, risk of aspiration.
Pregnancy.
Studieplan
Hur är studien utformad?
Designdetaljer
- Primärt syfte: Undersökning
- Tilldelning: Randomiserad
- Interventionsmodell: Parallellt uppdrag
- Maskning: Ingen (Open Label)
Vapen och interventioner
Deltagargrupp / Arm |
Intervention / Behandling |
|---|---|
|
Aktiv komparator: Group P: ProSeal.
Using computer-generated random numbers to assign patients to one of the three device groups: First group is Group P: ProSeal |
This multimodal approach, combining ultrasound assessment of sealing quality with biochemical monitoring of regurgitation, may provide valuable insights into the comparative effectiveness of different SAD designs and ensure patient safety.
Andra namn:
|
|
Aktiv komparator: Group I: i-gel.
Using computer-generated random numbers to assign patients to one of the three device groups: Second group Group I: i-gel. |
This multimodal approach, combining ultrasound assessment of sealing quality with biochemical monitoring of regurgitation, may provide valuable insights into the comparative effectiveness of different SAD designs and ensure patient safety.
Andra namn:
|
|
Aktiv komparator: Group I+: i-gel Plus.
Using computer-generated random numbers to assign patients to one of the three device groups: Third group Group I+: i-gel Plus. |
This multimodal approach, combining ultrasound assessment of sealing quality with biochemical monitoring of regurgitation, may provide valuable insights into the comparative effectiveness of different SAD designs and ensure patient safety.
Andra namn:
|
Vad mäter studien?
Primära resultatmått
Resultatmått |
Åtgärdsbeskrivning |
Tidsram |
|---|---|---|
|
Ultrasound mapping of sealing efficacy with correlation to OLP
Tidsram: The primary outcome will be assessed throw the operation time from 2 hours to 4 hours time frame to obtain this outcome.
|
evaluate the sealing quality of three second-generation SADs (ProSeal LMA, i-gel, and i-gel Plus) using ultrasonography to measure the cross-sectional area (CSA) of sealing, Anterior-Posterior (AP) Diameter and Transverse (TV) Diameter ,percentage of effective sealing , presence of sealing gap and correlate these anatomical findings with oropharyngeal leak pressure (OLP).
|
The primary outcome will be assessed throw the operation time from 2 hours to 4 hours time frame to obtain this outcome.
|
Sekundära resultatmått
Resultatmått |
Åtgärdsbeskrivning |
Tidsram |
|---|---|---|
|
Assessment for Regurgitation and microaspiration
Tidsram: Throw operative time a base line and at the end of operation before emergence of anathesia.
|
Post insertion of device, place a Salivary Collection Device in the oropharynx via the drainage channel for 5 minutes to collect secretion. Post-operatively A sample of saliva will be collected by the anesthesiologist, and the sample PH will be checked. |
Throw operative time a base line and at the end of operation before emergence of anathesia.
|
Samarbetspartners och utredare
Sponsor
Publikationer och användbara länkar
Allmänna publikationer
- Ahn, J. H., Jeong, J. S., Kang, S. H., Yeon, J. E., Cho, E. A., Choi, G. S., ... & Kim, G. S. (2021). Comparison of intragastric pressure between endotracheal tube and supraglottic airway devices in laparoscopic hepatectomy: A randomized, controlled, non-inferiority study. Medicine, 100(24), e26287. Jung, Y., Jung, S., Yu, S., Jeong, M. A., & Kim, C. L. (2024). Gastric distension and atelectasis after using a supraglottic airway-A case report. Anesthesia and Pain Medicine, 19(3), 261-265. O'Riordan, C., Van De Ven, P., Nelson, J., McCreesh, K., & Clifford, A. (2016). Reliability of a measurement method for the cross-sectional area of the longus colli using real-time ultrasound imaging. Ultrasound, 24(3), 154-162. Solanki, S. L., Johnson, J. E., & Samantaray, A. (2020). Supraglottic airway devices: Placement and pharyngeal seal matters!. Indian Journal of Anaesthesia, 64(8), 649-652. Werner, J., Klementova, O., Bruthans, J., Macoun, J., Gaszynski, T., Henlin, T., ... & Michalek, P. (2024). Evaluation of the i-gel® Plus supraglottic airway device in elective surgery: a prospective international multicentre study. Anaesthesia, 79(12), 1284-1291. Zhang, K., Zhou, M., Zou, Z., Zhu, C., & Jiang, R. (2024). Supraglottic airway devices: a powerful strategy in airway management. American journal of cancer research, 14(1), 16., ISO 690.
Studieavstämningsdatum
Studera stora datum
Studiestart (Faktisk)
Primärt slutförande (Beräknad)
Avslutad studie (Beräknad)
Studieregistreringsdatum
Först inskickad
Först inskickad som uppfyllde QC-kriterierna
Första postat (Faktisk)
Uppdateringar av studier
Senaste uppdatering publicerad (Faktisk)
Senaste inskickade uppdateringen som uppfyllde QC-kriterierna
Senast verifierad
Mer information
Termer relaterade till denna studie
Nyckelord
Ytterligare relevanta MeSH-villkor
Andra studie-ID-nummer
- FMASU317/2025
Plan för individuella deltagardata (IPD)
Planerar du att dela individuella deltagardata (IPD)?
Läkemedels- och apparatinformation, studiedokument
Studerar en amerikansk FDA-reglerad läkemedelsprodukt
Studerar en amerikansk FDA-reglerad produktprodukt
produkt tillverkad i och exporterad från U.S.A.
Denna information hämtades direkt från webbplatsen clinicaltrials.gov utan några ändringar. Om du har några önskemål om att ändra, ta bort eller uppdatera dina studieuppgifter, vänligen kontakta register@clinicaltrials.gov. Så snart en ändring har implementerats på clinicaltrials.gov, kommer denna att uppdateras automatiskt även på vår webbplats .