The Use of Ultrasound to Assess the Airway Anatomy Regarding Pharyngeal Seal and Its Protective Role Throw a Chemical Test for Three Supraglottic Devices (ProSeal LMA, I-gel, and I-gel Plus) (LMA)
Ultrasonographic Mapping of the Pharyngeal Seal and Its Protective Role for Three Supraglottic Devices (ProSeal LMA, I-gel, and I-gel Plus)
The goal of this clinical trial is to to evaluate the sealing quality of three second-generation SADs (ProSeal LMA, i-gel, and i-gel Plus) using ultrasonography to measure the cross-sectional area (CSA) of sealing, Anterior-Posterior (AP) Diameter and Transverse (TV) Diameter ,percentage of effective sealing , presence of sealing gap and correlate these anatomical findings with oropharyngeal leak pressure (OLP), while simultaneously testing relevant safety features of regurgitation risk through salivary pH measurement.
The findings from this investigation may contribute to improved device selection and enhanced patient safety during procedures requiring supraglottic airway management.
A tanulmány áttekintése
Állapot
Beavatkozás / kezelés
- Egyéb: evaluate the sealing quality (ProSeal LMA)using ultrasonography and a biochemical non invasive test to evaluate regurgitation
- Egyéb: evaluate the sealing quality of SGA device ( i-gel)using ultrasonography and a biochemical test for assessment of regurgitation
- Egyéb: evaluate the sealing quality of SGA device ( i-gel plus )using ultrasonography and a biochemical test for assessment of regurgitation
Tanulmány típusa
Beiratkozás (Becsült)
Fázis
- Nem alkalmazható
Kapcsolatok és helyek
Tanulmányi helyek
-
-
-
Cairo, Egyiptom
- Faculty of medicine ain shams university
-
-
Részvételi kritériumok
Jogosultsági kritériumok
Tanulmányozható életkorok
- Felnőtt
Egészséges önkénteseket fogad
Leírás
Inclusion Criteria:
- Age 18-55 years ASA physical status I or II, BMI 18-35 kg/m² Scheduled for elective surgery that requires around (2-3 hours) duration requiring general anesthesia with an SGAD.
Exclusion Criteria:
- History of gastroesophageal reflux disease (GERD) Known or anticipated difficult airway, pathology of the mouth/oropharynx/neck, risk of aspiration.
Pregnancy.
Tanulási terv
Hogyan készül a tanulmány?
Tervezési részletek
- Elsődleges cél: Szűrés
- Kiosztás: Véletlenszerűsített
- Beavatkozó modell: Párhuzamos hozzárendelés
- Maszkolás: Nincs (Open Label)
Fegyverek és beavatkozások
Résztvevő csoport / kar |
Beavatkozás / kezelés |
|---|---|
|
Aktív összehasonlító: Group P: ProSeal.
Using computer-generated random numbers to assign patients to one of the three device groups: First group is Group P: ProSeal |
This multimodal approach, combining ultrasound assessment of sealing quality with biochemical monitoring of regurgitation, may provide valuable insights into the comparative effectiveness of different SAD designs and ensure patient safety.
Más nevek:
|
|
Aktív összehasonlító: Group I: i-gel.
Using computer-generated random numbers to assign patients to one of the three device groups: Second group Group I: i-gel. |
This multimodal approach, combining ultrasound assessment of sealing quality with biochemical monitoring of regurgitation, may provide valuable insights into the comparative effectiveness of different SAD designs and ensure patient safety.
Más nevek:
|
|
Aktív összehasonlító: Group I+: i-gel Plus.
Using computer-generated random numbers to assign patients to one of the three device groups: Third group Group I+: i-gel Plus. |
This multimodal approach, combining ultrasound assessment of sealing quality with biochemical monitoring of regurgitation, may provide valuable insights into the comparative effectiveness of different SAD designs and ensure patient safety.
Más nevek:
|
Mit mér a tanulmány?
Elsődleges eredményintézkedések
Eredménymérő |
Intézkedés leírása |
Időkeret |
|---|---|---|
|
Ultrasound mapping of sealing efficacy with correlation to OLP
Időkeret: The primary outcome will be assessed throw the operation time from 2 hours to 4 hours time frame to obtain this outcome.
|
evaluate the sealing quality of three second-generation SADs (ProSeal LMA, i-gel, and i-gel Plus) using ultrasonography to measure the cross-sectional area (CSA) of sealing, Anterior-Posterior (AP) Diameter and Transverse (TV) Diameter ,percentage of effective sealing , presence of sealing gap and correlate these anatomical findings with oropharyngeal leak pressure (OLP).
|
The primary outcome will be assessed throw the operation time from 2 hours to 4 hours time frame to obtain this outcome.
|
Másodlagos eredményintézkedések
Eredménymérő |
Intézkedés leírása |
Időkeret |
|---|---|---|
|
Assessment for Regurgitation and microaspiration
Időkeret: Throw operative time a base line and at the end of operation before emergence of anathesia.
|
Post insertion of device, place a Salivary Collection Device in the oropharynx via the drainage channel for 5 minutes to collect secretion. Post-operatively A sample of saliva will be collected by the anesthesiologist, and the sample PH will be checked. |
Throw operative time a base line and at the end of operation before emergence of anathesia.
|
Együttműködők és nyomozók
Szponzor
Publikációk és hasznos linkek
Általános kiadványok
- Ahn, J. H., Jeong, J. S., Kang, S. H., Yeon, J. E., Cho, E. A., Choi, G. S., ... & Kim, G. S. (2021). Comparison of intragastric pressure between endotracheal tube and supraglottic airway devices in laparoscopic hepatectomy: A randomized, controlled, non-inferiority study. Medicine, 100(24), e26287. Jung, Y., Jung, S., Yu, S., Jeong, M. A., & Kim, C. L. (2024). Gastric distension and atelectasis after using a supraglottic airway-A case report. Anesthesia and Pain Medicine, 19(3), 261-265. O'Riordan, C., Van De Ven, P., Nelson, J., McCreesh, K., & Clifford, A. (2016). Reliability of a measurement method for the cross-sectional area of the longus colli using real-time ultrasound imaging. Ultrasound, 24(3), 154-162. Solanki, S. L., Johnson, J. E., & Samantaray, A. (2020). Supraglottic airway devices: Placement and pharyngeal seal matters!. Indian Journal of Anaesthesia, 64(8), 649-652. Werner, J., Klementova, O., Bruthans, J., Macoun, J., Gaszynski, T., Henlin, T., ... & Michalek, P. (2024). Evaluation of the i-gel® Plus supraglottic airway device in elective surgery: a prospective international multicentre study. Anaesthesia, 79(12), 1284-1291. Zhang, K., Zhou, M., Zou, Z., Zhu, C., & Jiang, R. (2024). Supraglottic airway devices: a powerful strategy in airway management. American journal of cancer research, 14(1), 16., ISO 690.
Tanulmányi rekorddátumok
Tanulmány főbb dátumok
Tanulmány kezdete (Tényleges)
Elsődleges befejezés (Becsült)
A tanulmány befejezése (Becsült)
Tanulmányi regisztráció dátumai
Először benyújtva
Először nyújtották be, amely megfelel a minőségbiztosítási kritériumoknak
Első közzététel (Tényleges)
Tanulmányi rekordok frissítései
Utolsó frissítés közzétéve (Tényleges)
Az utolsó frissítés elküldve, amely megfelel a minőségbiztosítási kritériumoknak
Utolsó ellenőrzés
Több információ
A tanulmányhoz kapcsolódó kifejezések
Kulcsszavak
További vonatkozó MeSH feltételek
Egyéb vizsgálati azonosító számok
- FMASU317/2025
Terv az egyéni résztvevői adatokhoz (IPD)
Tervezi megosztani az egyéni résztvevői adatokat (IPD)?
Gyógyszer- és eszközinformációk, tanulmányi dokumentumok
Egy amerikai FDA által szabályozott gyógyszerkészítményt tanulmányoz
Egy amerikai FDA által szabályozott eszközterméket tanulmányoz
az Egyesült Államokban gyártott és onnan exportált termék
Ezt az információt közvetlenül a clinicaltrials.gov webhelyről szereztük be, változtatás nélkül. Ha bármilyen kérése van vizsgálati adatainak módosítására, eltávolítására vagy frissítésére, kérjük, írjon a következő címre: register@clinicaltrials.gov. Amint a változás bevezetésre kerül a clinicaltrials.gov oldalon, ez a webhelyünkön is automatikusan frissül. .