Cette page a été traduite automatiquement et l'exactitude de la traduction n'est pas garantie. Veuillez vous référer au version anglaise pour un texte source.

Comparison of the Diagnostic Accuracy of 3D Volume Acquisition MRI With CT in Staging Colonic Cancer

19 juin 2017 mis à jour par: Royal Marsden NHS Foundation Trust
The purpose of this study is to determine whether MRI is more accurate than CT in determining the T stage, N stage, depth of tumour invasion and extra mural venous invasion (EMVI) preoperatively in colon cancer.

Aperçu de l'étude

Statut

Complété

Les conditions

Description détaillée

The patient will proceed with their usual colon cancer assessment and treatment, including colonoscopy with biopsy and histology and preoperative CT chest abdomen and pelvis. In addition, patients who enroll in the study will have 2 preoperative MRIs of their abdomen and pelvis performed. One of these will be performed on a 1.5T and the other will be performed on a 3.0T MRI scanner. We will use 20mg of IM buscopan to reduce bowel mobility for each scan. A coronal scout scan will be taken to identify the tumour and select the target volume. IV gadolinium (a contrast agent routinely used in MRI scans to help identify different tissues) will be administered, and a 3D VIBE scan (T1 weighted) will be performed of the target volume. The liver will also be imaged at this time to look for liver metastases. A T2 weighted 3D volume acquisition will then be obtained of the target volume containing the tumour (and its lymphatic drainage).

The MRI will be independently reported by an expert without knowledge of the results of any other investigations. The results of the MRI scan will then be made available to the clinical team. The patient will then proceed as normal with any other investigation which the clinical team feel is necessary, and be treated as normal for their colon cancer. The patient will proceed with their surgery as normal, and the specimen removed at the time of the operation will be examined in the pathology laboratory to determine the exact stage of the cancer.

The accuracy of CT and MRI in staging colon cancer will then be determined against the reference standard provided by the histology examination.

Type d'étude

Observationnel

Inscription (Réel)

60

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Lieux d'étude

    • Surrey
      • Sutton, Surrey, Royaume-Uni, SM2 5PT
        • The Royal Marsden NHS Foundation Trust

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

18 ans et plus (Adulte, Adulte plus âgé)

Accepte les volontaires sains

Non

Sexes éligibles pour l'étude

Tout

Méthode d'échantillonnage

Échantillon non probabiliste

Population étudiée

patients with colon cancer

La description

Inclusion Criteria:

  • patients undergoing treatment for colon cancer
  • patients undergoing primary surgery for colon cancer and who do not require neo-adjuvant therapy on the basis of their pre-operative CT

Exclusion Criteria:

  • age <18
  • unable to consent
  • consent withheld or withdrawn
  • Unable to have an MRI (e.g pacemaker, metal implant)
  • Allergy or contraindications to busocopam, gadolinium, small bowel contrast agent

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

Cohortes et interventions

Groupe / Cohorte
colon cancer
patients undergoing treatment for colon cancer

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
The primary endpoint will be the accuracy of MRI and CT in determining T stage using histology as the gold standard, on a per patient basis.

Mesures de résultats secondaires

Mesure des résultats
Secondary endpoints will be the accuracy of CT and MRI in determining N stage, depth of invasion beyond the muscularis propria, and EMVI.
We will also compare the accuracy of 1.5T against 3.0T MRI scans, and T2 weighted against T1 weighted images

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Les enquêteurs

  • Chercheur principal: Prof Gina Brown, Royal Marsden NHS Foundation Trust

Publications et liens utiles

La personne responsable de la saisie des informations sur l'étude fournit volontairement ces publications. Il peut s'agir de tout ce qui concerne l'étude.

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Réel)

18 août 2010

Achèvement primaire (Réel)

31 mars 2015

Achèvement de l'étude (Réel)

17 mai 2016

Dates d'inscription aux études

Première soumission

23 août 2010

Première soumission répondant aux critères de contrôle qualité

23 août 2010

Première publication (Estimation)

24 août 2010

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

20 juin 2017

Dernière mise à jour soumise répondant aux critères de contrôle qualité

19 juin 2017

Dernière vérification

1 juin 2017

Plus d'information

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

S'abonner