Deze pagina is automatisch vertaald en de nauwkeurigheid van de vertaling kan niet worden gegarandeerd. Raadpleeg de Engelse versie voor een brontekst.

Comparison of the Diagnostic Accuracy of 3D Volume Acquisition MRI With CT in Staging Colonic Cancer

19 juni 2017 bijgewerkt door: Royal Marsden NHS Foundation Trust
The purpose of this study is to determine whether MRI is more accurate than CT in determining the T stage, N stage, depth of tumour invasion and extra mural venous invasion (EMVI) preoperatively in colon cancer.

Studie Overzicht

Toestand

Voltooid

Conditie

Gedetailleerde beschrijving

The patient will proceed with their usual colon cancer assessment and treatment, including colonoscopy with biopsy and histology and preoperative CT chest abdomen and pelvis. In addition, patients who enroll in the study will have 2 preoperative MRIs of their abdomen and pelvis performed. One of these will be performed on a 1.5T and the other will be performed on a 3.0T MRI scanner. We will use 20mg of IM buscopan to reduce bowel mobility for each scan. A coronal scout scan will be taken to identify the tumour and select the target volume. IV gadolinium (a contrast agent routinely used in MRI scans to help identify different tissues) will be administered, and a 3D VIBE scan (T1 weighted) will be performed of the target volume. The liver will also be imaged at this time to look for liver metastases. A T2 weighted 3D volume acquisition will then be obtained of the target volume containing the tumour (and its lymphatic drainage).

The MRI will be independently reported by an expert without knowledge of the results of any other investigations. The results of the MRI scan will then be made available to the clinical team. The patient will then proceed as normal with any other investigation which the clinical team feel is necessary, and be treated as normal for their colon cancer. The patient will proceed with their surgery as normal, and the specimen removed at the time of the operation will be examined in the pathology laboratory to determine the exact stage of the cancer.

The accuracy of CT and MRI in staging colon cancer will then be determined against the reference standard provided by the histology examination.

Studietype

Observationeel

Inschrijving (Werkelijk)

60

Contacten en locaties

In dit gedeelte vindt u de contactgegevens van degenen die het onderzoek uitvoeren en informatie over waar dit onderzoek wordt uitgevoerd.

Studie Locaties

    • Surrey
      • Sutton, Surrey, Verenigd Koninkrijk, SM2 5PT
        • The Royal Marsden NHS Foundation Trust

Deelname Criteria

Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.

Geschiktheidscriteria

Leeftijden die in aanmerking komen voor studie

18 jaar en ouder (Volwassen, Oudere volwassene)

Accepteert gezonde vrijwilligers

Nee

Geslachten die in aanmerking komen voor studie

Allemaal

Bemonsteringsmethode

Niet-waarschijnlijkheidssteekproef

Studie Bevolking

patients with colon cancer

Beschrijving

Inclusion Criteria:

  • patients undergoing treatment for colon cancer
  • patients undergoing primary surgery for colon cancer and who do not require neo-adjuvant therapy on the basis of their pre-operative CT

Exclusion Criteria:

  • age <18
  • unable to consent
  • consent withheld or withdrawn
  • Unable to have an MRI (e.g pacemaker, metal implant)
  • Allergy or contraindications to busocopam, gadolinium, small bowel contrast agent

Studie plan

Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.

Hoe is de studie opgezet?

Ontwerpdetails

Cohorten en interventies

Groep / Cohort
colon cancer
patients undergoing treatment for colon cancer

Wat meet het onderzoek?

Primaire uitkomstmaten

Uitkomstmaat
The primary endpoint will be the accuracy of MRI and CT in determining T stage using histology as the gold standard, on a per patient basis.

Secundaire uitkomstmaten

Uitkomstmaat
Secondary endpoints will be the accuracy of CT and MRI in determining N stage, depth of invasion beyond the muscularis propria, and EMVI.
We will also compare the accuracy of 1.5T against 3.0T MRI scans, and T2 weighted against T1 weighted images

Medewerkers en onderzoekers

Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.

Onderzoekers

  • Hoofdonderzoeker: Prof Gina Brown, Royal Marsden NHS Foundation Trust

Publicaties en nuttige links

De persoon die verantwoordelijk is voor het invoeren van informatie over het onderzoek stelt deze publicaties vrijwillig ter beschikking. Dit kan gaan over alles wat met het onderzoek te maken heeft.

Studie record data

Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.

Bestudeer belangrijke data

Studie start (Werkelijk)

18 augustus 2010

Primaire voltooiing (Werkelijk)

31 maart 2015

Studie voltooiing (Werkelijk)

17 mei 2016

Studieregistratiedata

Eerst ingediend

23 augustus 2010

Eerst ingediend dat voldeed aan de QC-criteria

23 augustus 2010

Eerst geplaatst (Schatting)

24 augustus 2010

Updates van studierecords

Laatste update geplaatst (Werkelijk)

20 juni 2017

Laatste update ingediend die voldeed aan QC-criteria

19 juni 2017

Laatst geverifieerd

1 juni 2017

Meer informatie

Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .

Abonneren