Denna sida har översatts automatiskt och översättningens korrekthet kan inte garanteras. Vänligen se engelsk version för en källtext.

Comparison of the Diagnostic Accuracy of 3D Volume Acquisition MRI With CT in Staging Colonic Cancer

19 juni 2017 uppdaterad av: Royal Marsden NHS Foundation Trust
The purpose of this study is to determine whether MRI is more accurate than CT in determining the T stage, N stage, depth of tumour invasion and extra mural venous invasion (EMVI) preoperatively in colon cancer.

Studieöversikt

Status

Avslutad

Betingelser

Detaljerad beskrivning

The patient will proceed with their usual colon cancer assessment and treatment, including colonoscopy with biopsy and histology and preoperative CT chest abdomen and pelvis. In addition, patients who enroll in the study will have 2 preoperative MRIs of their abdomen and pelvis performed. One of these will be performed on a 1.5T and the other will be performed on a 3.0T MRI scanner. We will use 20mg of IM buscopan to reduce bowel mobility for each scan. A coronal scout scan will be taken to identify the tumour and select the target volume. IV gadolinium (a contrast agent routinely used in MRI scans to help identify different tissues) will be administered, and a 3D VIBE scan (T1 weighted) will be performed of the target volume. The liver will also be imaged at this time to look for liver metastases. A T2 weighted 3D volume acquisition will then be obtained of the target volume containing the tumour (and its lymphatic drainage).

The MRI will be independently reported by an expert without knowledge of the results of any other investigations. The results of the MRI scan will then be made available to the clinical team. The patient will then proceed as normal with any other investigation which the clinical team feel is necessary, and be treated as normal for their colon cancer. The patient will proceed with their surgery as normal, and the specimen removed at the time of the operation will be examined in the pathology laboratory to determine the exact stage of the cancer.

The accuracy of CT and MRI in staging colon cancer will then be determined against the reference standard provided by the histology examination.

Studietyp

Observationell

Inskrivning (Faktisk)

60

Kontakter och platser

Det här avsnittet innehåller kontaktuppgifter för dem som genomför studien och information om var denna studie genomförs.

Studieorter

    • Surrey
      • Sutton, Surrey, Storbritannien, SM2 5PT
        • The Royal Marsden NHS Foundation Trust

Deltagandekriterier

Forskare letar efter personer som passar en viss beskrivning, så kallade behörighetskriterier. Några exempel på dessa kriterier är en persons allmänna hälsotillstånd eller tidigare behandlingar.

Urvalskriterier

Åldrar som är berättigade till studier

18 år och äldre (Vuxen, Äldre vuxen)

Tar emot friska volontärer

Nej

Kön som är behöriga för studier

Allt

Testmetod

Icke-sannolikhetsprov

Studera befolkning

patients with colon cancer

Beskrivning

Inclusion Criteria:

  • patients undergoing treatment for colon cancer
  • patients undergoing primary surgery for colon cancer and who do not require neo-adjuvant therapy on the basis of their pre-operative CT

Exclusion Criteria:

  • age <18
  • unable to consent
  • consent withheld or withdrawn
  • Unable to have an MRI (e.g pacemaker, metal implant)
  • Allergy or contraindications to busocopam, gadolinium, small bowel contrast agent

Studieplan

Det här avsnittet ger detaljer om studieplanen, inklusive hur studien är utformad och vad studien mäter.

Hur är studien utformad?

Designdetaljer

Kohorter och interventioner

Grupp / Kohort
colon cancer
patients undergoing treatment for colon cancer

Vad mäter studien?

Primära resultatmått

Resultatmått
The primary endpoint will be the accuracy of MRI and CT in determining T stage using histology as the gold standard, on a per patient basis.

Sekundära resultatmått

Resultatmått
Secondary endpoints will be the accuracy of CT and MRI in determining N stage, depth of invasion beyond the muscularis propria, and EMVI.
We will also compare the accuracy of 1.5T against 3.0T MRI scans, and T2 weighted against T1 weighted images

Samarbetspartners och utredare

Det är här du hittar personer och organisationer som är involverade i denna studie.

Utredare

  • Huvudutredare: Prof Gina Brown, Royal Marsden NHS Foundation Trust

Publikationer och användbara länkar

Den som ansvarar för att lägga in information om studien tillhandahåller frivilligt dessa publikationer. Dessa kan handla om allt som har med studien att göra.

Studieavstämningsdatum

Dessa datum spårar framstegen för inlämningar av studieposter och sammanfattande resultat till ClinicalTrials.gov. Studieposter och rapporterade resultat granskas av National Library of Medicine (NLM) för att säkerställa att de uppfyller specifika kvalitetskontrollstandarder innan de publiceras på den offentliga webbplatsen.

Studera stora datum

Studiestart (Faktisk)

18 augusti 2010

Primärt slutförande (Faktisk)

31 mars 2015

Avslutad studie (Faktisk)

17 maj 2016

Studieregistreringsdatum

Först inskickad

23 augusti 2010

Först inskickad som uppfyllde QC-kriterierna

23 augusti 2010

Första postat (Uppskatta)

24 augusti 2010

Uppdateringar av studier

Senaste uppdatering publicerad (Faktisk)

20 juni 2017

Senaste inskickade uppdateringen som uppfyllde QC-kriterierna

19 juni 2017

Senast verifierad

1 juni 2017

Mer information

Denna information hämtades direkt från webbplatsen clinicaltrials.gov utan några ändringar. Om du har några önskemål om att ändra, ta bort eller uppdatera dina studieuppgifter, vänligen kontakta register@clinicaltrials.gov. Så snart en ändring har implementerats på clinicaltrials.gov, kommer denna att uppdateras automatiskt även på vår webbplats .

Prenumerera