Monitoring of Fluid Status in Heart Failure Patients by Intrathoracic Impedance Measurement in Japan (J-HomeCARE II)
Monitoring of Fluid Status in Heart Failure Patients by Intrathoracic Impedance Measurement in Japan
Aperçu de l'étude
Statut
Les conditions
Intervention / Traitement
Description détaillée
The new BIOTRONIK ICD family Lumax 540 is capable of measuring the intrathoracic impedance on a daily basis and transmission of impedance trend data via the Home Monitoring technology. In future, this will allow for automatic early detection of imminent decompensation at a presymptomatic stage and immediate initialization of clinical meaningful therapeutic interventions preventing heart failure related hospitalizations. The aim of this investigation is to record long-term impedance trends in heart failure patients with and without HF related events (hospitalizations due to acute decompensation) in order to develop algorithms for device-based early detection and warning of HF deterioration accompanied by pulmonary congestion.
Lumax is the name of a family of implantable ICDs. The primary objective of the therapy is the prevention of sudden cardiac death. The aim is to automatically detect and terminate cardiac arrest caused by ventricular tachyarrhythmia. All major therapeutical approaches from the field of cardiology and electrophysiology are contained within the Lumax family.
Furthermore, the device is capable of treating bradycardia arrhythmias and congestive heart failure. Congestive heart failure is treated with cardiac resynchronization therapy with multisite ventricular pacing known as cardiac resynchronization therapy (CRT).
The integrated Home Monitoring component can provide information about occurring rhythm disturbances and delivered therapies close to real time as well as by intracardiac electrogram (IEGM) Online HD®. Furthermore, statistical data about the patient's condition as well as information about the integrity status of the implant itself are sent.
The implantation of an ICD is a symptomatic therapy with the following objectives:
Termination of spontaneous ventricular fibrillation (VF) through shock delivery Termination of spontaneous ventricular tachycardia (VT) by means of antitachycardia pacing (ATP); in case of ineffective ATP or hemodynamically not tolerated VT with shock delivery Cardiac resynchronization by multisite ventricular pacing (triple-chamber implant) Compensation of bradycardia through ventricular (single-chamber implant) or atrioventricular sequential pacing (dual- and triple-chamber implant)
Type d'étude
Inscription (Réel)
Phase
- Phase 4
Contacts et emplacements
Lieux d'étude
-
-
-
Hiroshima, Japon
- Hiroshima Shimin Hospital
-
Tokyo, Japon
- Tokyo Women's Medical University
-
-
Fukuoka
-
Kitakyushu, Fukuoka, Japon, 802-8555
- Kokura Kinen Hospital
-
-
Mie
-
Ise, Mie, Japon, 516-0805
- Yamada Red Cross Hospital
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
La description
Inclusion Criteria:
- Patient eligible for 1-, 2- or 3-chamber ICD implantation according to current guidelines or patient already implanted with a Lumax 540 device or successor
- New York Heart Association (NYHA)-class II to IV
- Left ventricular ejection fraction (LVEF) lower or equal to 35%
- Patient accepts Home Monitoring concept and has sufficient Global System for Mobile Communications (GSM) /General Packet Radio Service (GPRS) net coverage
- Increased risk for HF-related hospitalization according to pre-defined criteria
- Patient information
- Informed consent
Exclusion Criteria:
- Age < 18 years
- Contraindication for ICD implantation
- Post heart transplant (HTX) or actively listed for HTX
- Cardiac surgery within the previous 3 months or planned at time of inclusion
- Acute coronary syndrome within the previous 3 months
- Chronic renal dialysis
- Pregnant or breast-feeding women
- Limited contractual capability
- Participation in another study
- Anticipated non-compliance with the follow-up scheme
- Life expectancy not longer than 1.5 years due to a non-cardiac disease
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Soins de soutien
- Répartition: N / A
- Modèle interventionnel: Affectation à un seul groupe
- Masquage: Aucun (étiquette ouverte)
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
HF Events
Délai: 21 months follow-up
|
Long-term impedance trends in patients with clinically relevant HF events, to support the development of impedance based detection algorithms.
A posterior assessment of sensitivity and false alarm rate of the detection algorithms.
|
21 months follow-up
|
Collaborateurs et enquêteurs
Parrainer
Les enquêteurs
- Chercheur principal: Shoda Morio, DR, Tokyo Women's University Hospital
Publications et liens utiles
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude
Achèvement primaire (Réel)
Achèvement de l'étude (Réel)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Estimation)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Estimation)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- JHC2
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .