- ICH GCP
- Register voor klinische proeven in de VS.
- Klinische proef NCT01221649
Monitoring of Fluid Status in Heart Failure Patients by Intrathoracic Impedance Measurement in Japan (J-HomeCARE II)
Monitoring of Fluid Status in Heart Failure Patients by Intrathoracic Impedance Measurement in Japan
Studie Overzicht
Gedetailleerde beschrijving
The new BIOTRONIK ICD family Lumax 540 is capable of measuring the intrathoracic impedance on a daily basis and transmission of impedance trend data via the Home Monitoring technology. In future, this will allow for automatic early detection of imminent decompensation at a presymptomatic stage and immediate initialization of clinical meaningful therapeutic interventions preventing heart failure related hospitalizations. The aim of this investigation is to record long-term impedance trends in heart failure patients with and without HF related events (hospitalizations due to acute decompensation) in order to develop algorithms for device-based early detection and warning of HF deterioration accompanied by pulmonary congestion.
Lumax is the name of a family of implantable ICDs. The primary objective of the therapy is the prevention of sudden cardiac death. The aim is to automatically detect and terminate cardiac arrest caused by ventricular tachyarrhythmia. All major therapeutical approaches from the field of cardiology and electrophysiology are contained within the Lumax family.
Furthermore, the device is capable of treating bradycardia arrhythmias and congestive heart failure. Congestive heart failure is treated with cardiac resynchronization therapy with multisite ventricular pacing known as cardiac resynchronization therapy (CRT).
The integrated Home Monitoring component can provide information about occurring rhythm disturbances and delivered therapies close to real time as well as by intracardiac electrogram (IEGM) Online HD®. Furthermore, statistical data about the patient's condition as well as information about the integrity status of the implant itself are sent.
The implantation of an ICD is a symptomatic therapy with the following objectives:
Termination of spontaneous ventricular fibrillation (VF) through shock delivery Termination of spontaneous ventricular tachycardia (VT) by means of antitachycardia pacing (ATP); in case of ineffective ATP or hemodynamically not tolerated VT with shock delivery Cardiac resynchronization by multisite ventricular pacing (triple-chamber implant) Compensation of bradycardia through ventricular (single-chamber implant) or atrioventricular sequential pacing (dual- and triple-chamber implant)
Studietype
Inschrijving (Werkelijk)
Fase
- Fase 4
Contacten en locaties
Studie Locaties
-
-
-
Hiroshima, Japan
- Hiroshima Shimin Hospital
-
Tokyo, Japan
- Tokyo Women's Medical University
-
-
Fukuoka
-
Kitakyushu, Fukuoka, Japan, 802-8555
- Kokura Kinen Hospital
-
-
Mie
-
Ise, Mie, Japan, 516-0805
- Yamada Red Cross Hospital
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
Accepteert gezonde vrijwilligers
Geslachten die in aanmerking komen voor studie
Beschrijving
Inclusion Criteria:
- Patient eligible for 1-, 2- or 3-chamber ICD implantation according to current guidelines or patient already implanted with a Lumax 540 device or successor
- New York Heart Association (NYHA)-class II to IV
- Left ventricular ejection fraction (LVEF) lower or equal to 35%
- Patient accepts Home Monitoring concept and has sufficient Global System for Mobile Communications (GSM) /General Packet Radio Service (GPRS) net coverage
- Increased risk for HF-related hospitalization according to pre-defined criteria
- Patient information
- Informed consent
Exclusion Criteria:
- Age < 18 years
- Contraindication for ICD implantation
- Post heart transplant (HTX) or actively listed for HTX
- Cardiac surgery within the previous 3 months or planned at time of inclusion
- Acute coronary syndrome within the previous 3 months
- Chronic renal dialysis
- Pregnant or breast-feeding women
- Limited contractual capability
- Participation in another study
- Anticipated non-compliance with the follow-up scheme
- Life expectancy not longer than 1.5 years due to a non-cardiac disease
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
- Primair doel: Ondersteunende zorg
- Toewijzing: NVT
- Interventioneel model: Opdracht voor een enkele groep
- Masker: Geen (open label)
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
HF Events
Tijdsspanne: 21 months follow-up
|
Long-term impedance trends in patients with clinically relevant HF events, to support the development of impedance based detection algorithms.
A posterior assessment of sensitivity and false alarm rate of the detection algorithms.
|
21 months follow-up
|
Medewerkers en onderzoekers
Sponsor
Onderzoekers
- Hoofdonderzoeker: Shoda Morio, DR, Tokyo Women's University Hospital
Publicaties en nuttige links
Studie record data
Bestudeer belangrijke data
Studie start
Primaire voltooiing (Werkelijk)
Studie voltooiing (Werkelijk)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Schatting)
Updates van studierecords
Laatste update geplaatst (Schatting)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Aanvullende relevante MeSH-voorwaarden
Andere studie-ID-nummers
- JHC2
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .