Denne siden ble automatisk oversatt og nøyaktigheten av oversettelsen er ikke garantert. Vennligst referer til engelsk versjon for en kildetekst.

Monitoring of Fluid Status in Heart Failure Patients by Intrathoracic Impedance Measurement in Japan (J-HomeCARE II)

8. oktober 2015 oppdatert av: Biotronik Japan, Inc.

Monitoring of Fluid Status in Heart Failure Patients by Intrathoracic Impedance Measurement in Japan

The new BIOTRONIK implantable cardioverter defibrillator (ICD) family Lumax 540 is capable of measuring the intrathoracic impedance on a daily basis and transmission of impedance trend data via the Home Monitoring technology. In future, this will allow for automatic early detection of imminent decompensation at a presymptomatic stage and immediate initialization of clinical meaningful therapeutic interventions preventing heart failure (HF) related hospitalizations. The aim of this investigation is to record long-term impedance trends in heart failure patients with and without heart failure related events (hospitalizations due to acute decompensation) in order to develop algorithms for device-based early detection and warning of HF deterioration accompanied by pulmonary congestion.

Studieoversikt

Status

Fullført

Intervensjon / Behandling

Detaljert beskrivelse

The new BIOTRONIK ICD family Lumax 540 is capable of measuring the intrathoracic impedance on a daily basis and transmission of impedance trend data via the Home Monitoring technology. In future, this will allow for automatic early detection of imminent decompensation at a presymptomatic stage and immediate initialization of clinical meaningful therapeutic interventions preventing heart failure related hospitalizations. The aim of this investigation is to record long-term impedance trends in heart failure patients with and without HF related events (hospitalizations due to acute decompensation) in order to develop algorithms for device-based early detection and warning of HF deterioration accompanied by pulmonary congestion.

Lumax is the name of a family of implantable ICDs. The primary objective of the therapy is the prevention of sudden cardiac death. The aim is to automatically detect and terminate cardiac arrest caused by ventricular tachyarrhythmia. All major therapeutical approaches from the field of cardiology and electrophysiology are contained within the Lumax family.

Furthermore, the device is capable of treating bradycardia arrhythmias and congestive heart failure. Congestive heart failure is treated with cardiac resynchronization therapy with multisite ventricular pacing known as cardiac resynchronization therapy (CRT).

The integrated Home Monitoring component can provide information about occurring rhythm disturbances and delivered therapies close to real time as well as by intracardiac electrogram (IEGM) Online HD®. Furthermore, statistical data about the patient's condition as well as information about the integrity status of the implant itself are sent.

The implantation of an ICD is a symptomatic therapy with the following objectives:

Termination of spontaneous ventricular fibrillation (VF) through shock delivery Termination of spontaneous ventricular tachycardia (VT) by means of antitachycardia pacing (ATP); in case of ineffective ATP or hemodynamically not tolerated VT with shock delivery Cardiac resynchronization by multisite ventricular pacing (triple-chamber implant) Compensation of bradycardia through ventricular (single-chamber implant) or atrioventricular sequential pacing (dual- and triple-chamber implant)

Studietype

Intervensjonell

Registrering (Faktiske)

198

Fase

  • Fase 4

Kontakter og plasseringer

Denne delen inneholder kontaktinformasjon for de som utfører studien, og informasjon om hvor denne studien blir utført.

Studiesteder

      • Hiroshima, Japan
        • Hiroshima Shimin Hospital
      • Tokyo, Japan
        • Tokyo Women's Medical University
    • Fukuoka
      • Kitakyushu, Fukuoka, Japan, 802-8555
        • Kokura Kinen Hospital
    • Mie
      • Ise, Mie, Japan, 516-0805
        • Yamada Red Cross Hospital

Deltakelseskriterier

Forskere ser etter personer som passer til en bestemt beskrivelse, kalt kvalifikasjonskriterier. Noen eksempler på disse kriteriene er en persons generelle helsetilstand eller tidligere behandlinger.

Kvalifikasjonskriterier

Alder som er kvalifisert for studier

18 år og eldre (Voksen, Eldre voksen)

Tar imot friske frivillige

Nei

Kjønn som er kvalifisert for studier

Alle

Beskrivelse

Inclusion Criteria:

  • Patient eligible for 1-, 2- or 3-chamber ICD implantation according to current guidelines or patient already implanted with a Lumax 540 device or successor
  • New York Heart Association (NYHA)-class II to IV
  • Left ventricular ejection fraction (LVEF) lower or equal to 35%
  • Patient accepts Home Monitoring concept and has sufficient Global System for Mobile Communications (GSM) /General Packet Radio Service (GPRS) net coverage
  • Increased risk for HF-related hospitalization according to pre-defined criteria
  • Patient information
  • Informed consent

Exclusion Criteria:

  • Age < 18 years
  • Contraindication for ICD implantation
  • Post heart transplant (HTX) or actively listed for HTX
  • Cardiac surgery within the previous 3 months or planned at time of inclusion
  • Acute coronary syndrome within the previous 3 months
  • Chronic renal dialysis
  • Pregnant or breast-feeding women
  • Limited contractual capability
  • Participation in another study
  • Anticipated non-compliance with the follow-up scheme
  • Life expectancy not longer than 1.5 years due to a non-cardiac disease

Studieplan

Denne delen gir detaljer om studieplanen, inkludert hvordan studien er utformet og hva studien måler.

Hvordan er studiet utformet?

Designdetaljer

  • Primært formål: Støttende omsorg
  • Tildeling: N/A
  • Intervensjonsmodell: Enkeltgruppeoppdrag
  • Masking: Ingen (Open Label)

Hva måler studien?

Primære resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
HF Events
Tidsramme: 21 months follow-up
Long-term impedance trends in patients with clinically relevant HF events, to support the development of impedance based detection algorithms. A posterior assessment of sensitivity and false alarm rate of the detection algorithms.
21 months follow-up

Samarbeidspartnere og etterforskere

Det er her du vil finne personer og organisasjoner som er involvert i denne studien.

Etterforskere

  • Hovedetterforsker: Shoda Morio, DR, Tokyo Women's University Hospital

Publikasjoner og nyttige lenker

Den som er ansvarlig for å legge inn informasjon om studien leverer frivillig disse publikasjonene. Disse kan handle om alt relatert til studiet.

Studierekorddatoer

Disse datoene sporer fremdriften for innsending av studieposter og sammendragsresultater til ClinicalTrials.gov. Studieposter og rapporterte resultater gjennomgås av National Library of Medicine (NLM) for å sikre at de oppfyller spesifikke kvalitetskontrollstandarder før de legges ut på det offentlige nettstedet.

Studer hoveddatoer

Studiestart

1. juni 2010

Primær fullføring (Faktiske)

1. februar 2014

Studiet fullført (Faktiske)

1. februar 2014

Datoer for studieregistrering

Først innsendt

12. oktober 2010

Først innsendt som oppfylte QC-kriteriene

14. oktober 2010

Først lagt ut (Anslag)

15. oktober 2010

Oppdateringer av studieposter

Sist oppdatering lagt ut (Anslag)

12. oktober 2015

Siste oppdatering sendt inn som oppfylte QC-kriteriene

8. oktober 2015

Sist bekreftet

1. februar 2012

Mer informasjon

Begreper knyttet til denne studien

Andre studie-ID-numre

  • JHC2

Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .