- ICH GCP
- Registre américain des essais cliniques
- Essai clinique NCT02331199
Comparison Between Amniotic Fluid Lamellar Body Count and Fetal Pulmonary Artery Doppler Indices in Predicting Fetal Lung Maturity
Aperçu de l'étude
Statut
Les conditions
Intervention / Traitement
Description détaillée
Neonatal respiratory distress syndrome (RDS) remains a major cause of neonatal morbidity and mortality. A recent epidemiologic study in the United States estimates that there are 80,000 cases of neonatal RDS each year, resulting in 8500 deaths and hospital costs in excess of $4.4 billion.
A number of biochemical tests have been developed to predict the risk of RDS and assist obstetric care providers in delivery timing. Amniotic fluid lamellar body count (LBC) is an important biophysical test, based on measuring the concentration of pulmonary surfactant in amniotic fluid. It can be effectively used to assess fetal lung maturity. A noninvasive test for fetal lung maturity (FLM) would be useful to minimize the need for invasive testing and would be more acceptable to women. Fetal pulmonary artery Doppler waveform acceleration/ejection time may provide a noninvasive means of determining fetal lung maturity with relatively acceptable levels of sensitivity, specificity, and predictive values.
The investigators will study 200 women with singleton pregnancies presented with prelabor preterm rupture of membranes or undergoing cesarean section (CS). Amniotic fluid lamellar body count (LBC) and fetal pulmonary artery Doppler will be done to all women. LBC and fetal pulmonary artery Doppler will be correlated with fetal outcome.
Quantitative data will be statistically represented in terms of mean ± standard deviation (± SD) while categorical data will be represented as frequency and percentage. Comparison of quantitative data will be done using Mann Whitney U test for independent samples while categorical data will compared using Chi squared test or Fisher exact test when appropriate. A probability value (p value) less than 0.05 will be considered significant.
Type d'étude
Inscription (Anticipé)
Phase
- Phase 3
Contacts et emplacements
Lieux d'étude
-
-
-
Cairo, Egypte
- Recrutement
- Cairo university hospitals
-
Contact:
- AbdelGany Hassan, MRCOG, MD
- Numéro de téléphone: 002 01017801604
- E-mail: abdelgany2@gmail.com
-
Sous-enquêteur:
- AbdelGany MA Hassan, MRCOG, MD
-
Chercheur principal:
- Sherif Negm, MD
-
Sous-enquêteur:
- Doaa Salah, MD
-
Cairo, Egypte
- Recrutement
- Al Galaa maternity fospital
-
Contact:
- Mohamed Wafeek
- Numéro de téléphone: 002 01223524286
-
Chercheur principal:
- Mohamed Wafeek
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
La description
Inclusion Criteria:
- Singleton pregnancies without any major congenital anomalies.
- Gestation between 32-36 weeks
- Women presenting preterm pre-labour ruptured membranes or undergoing a cesarean section.
Exclusion Criteria:
- Patients with major fetal anomalies.
- Bloody or meconium stained amniotic fluid
- preexisting maternal medical conditions (eg, diabetes, renal disease, hypertensive disorders, vaginal bleeding
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Diagnostique
- Répartition: N / A
- Modèle interventionnel: Affectation à un seul groupe
- Masquage: Aucun (étiquette ouverte)
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
|---|---|
|
Expérimental: preterm labour
200 women with preterm prelabour ruptured membranes or undergoing preterm CS
|
The LBC (the unit of measurement is number of lamellar bodies counted per microliter of amniotic fluid) will be determined using the platelet channels on the Hematology Flow Cytometer.
Autres noms:
A fetal pulmonary artery Doppler will be performed using color Doppler ultrasound.
Doppler flow velocity measurements, including systolic/diastolic ratio, pulsatility index, resistance index, and acceleration-time/ejection-time ratio using spectral Doppler ultrasound.
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Respiratory distress syndrome (RDS)
Délai: 1 day after delivery
|
RDS will be diagnosed clinically by the presence of tachypnea, working respiratory muscles, expiratory grunt, and chest x-ray.
|
1 day after delivery
|
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Need for incubation
Délai: 1 day after delivery
|
It will be recorded if the pediatrician decides to incubate the neonate.
The reason for incubation e.g.
ventilation, hypoxia, ischemia will be recorded.
|
1 day after delivery
|
Collaborateurs et enquêteurs
Parrainer
Publications et liens utiles
Publications générales
- AVERY ME, MEAD J. Surface properties in relation to atelectasis and hyaline membrane disease. AMA J Dis Child. 1959 May;97(5, Part 1):517-23. doi: 10.1001/archpedi.1959.02070010519001. No abstract available.
- Dubin SB. Characterization of amniotic fluid lamellar bodies by resistive-pulse counting: relationship to measures of fetal lung maturity. Clin Chem. 1989 Apr;35(4):612-6.
- Neerhof MG, Dohnal JC, Ashwood ER, Lee IS, Anceschi MM. Lamellar body counts: a consensus on protocol. Obstet Gynecol. 2001 Feb;97(2):318-20. doi: 10.1016/s0029-7844(00)01134-0.
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude
Achèvement primaire (Anticipé)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Estimation)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Estimation)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- preterm 1
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .