- ICH GCP
- Registro degli studi clinici negli Stati Uniti
- Sperimentazione clinica NCT02331199
Comparison Between Amniotic Fluid Lamellar Body Count and Fetal Pulmonary Artery Doppler Indices in Predicting Fetal Lung Maturity
Panoramica dello studio
Stato
Condizioni
Intervento / Trattamento
Descrizione dettagliata
Neonatal respiratory distress syndrome (RDS) remains a major cause of neonatal morbidity and mortality. A recent epidemiologic study in the United States estimates that there are 80,000 cases of neonatal RDS each year, resulting in 8500 deaths and hospital costs in excess of $4.4 billion.
A number of biochemical tests have been developed to predict the risk of RDS and assist obstetric care providers in delivery timing. Amniotic fluid lamellar body count (LBC) is an important biophysical test, based on measuring the concentration of pulmonary surfactant in amniotic fluid. It can be effectively used to assess fetal lung maturity. A noninvasive test for fetal lung maturity (FLM) would be useful to minimize the need for invasive testing and would be more acceptable to women. Fetal pulmonary artery Doppler waveform acceleration/ejection time may provide a noninvasive means of determining fetal lung maturity with relatively acceptable levels of sensitivity, specificity, and predictive values.
The investigators will study 200 women with singleton pregnancies presented with prelabor preterm rupture of membranes or undergoing cesarean section (CS). Amniotic fluid lamellar body count (LBC) and fetal pulmonary artery Doppler will be done to all women. LBC and fetal pulmonary artery Doppler will be correlated with fetal outcome.
Quantitative data will be statistically represented in terms of mean ± standard deviation (± SD) while categorical data will be represented as frequency and percentage. Comparison of quantitative data will be done using Mann Whitney U test for independent samples while categorical data will compared using Chi squared test or Fisher exact test when appropriate. A probability value (p value) less than 0.05 will be considered significant.
Tipo di studio
Iscrizione (Anticipato)
Fase
- Fase 3
Contatti e Sedi
Contatto studio
- Nome: AbdelGany MA Hassan, MRCOG, MD
- Numero di telefono: +201017801604
- Email: abdelgany2@gmail.com
Luoghi di studio
-
-
-
Cairo, Egitto
- Reclutamento
- Cairo University Hospitals
-
Contatto:
- AbdelGany Hassan, MRCOG, MD
- Numero di telefono: 002 01017801604
- Email: abdelgany2@gmail.com
-
Sub-investigatore:
- AbdelGany MA Hassan, MRCOG, MD
-
Investigatore principale:
- Sherif Negm, MD
-
Sub-investigatore:
- Doaa Salah, MD
-
Cairo, Egitto
- Reclutamento
- Al Galaa maternity fospital
-
Contatto:
- Mohamed Wafeek
- Numero di telefono: 002 01223524286
-
Investigatore principale:
- Mohamed Wafeek
-
-
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Descrizione
Inclusion Criteria:
- Singleton pregnancies without any major congenital anomalies.
- Gestation between 32-36 weeks
- Women presenting preterm pre-labour ruptured membranes or undergoing a cesarean section.
Exclusion Criteria:
- Patients with major fetal anomalies.
- Bloody or meconium stained amniotic fluid
- preexisting maternal medical conditions (eg, diabetes, renal disease, hypertensive disorders, vaginal bleeding
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Diagnostico
- Assegnazione: N / A
- Modello interventistico: Assegnazione di gruppo singolo
- Mascheramento: Nessuno (etichetta aperta)
Armi e interventi
Gruppo di partecipanti / Arm |
Intervento / Trattamento |
---|---|
Sperimentale: preterm labour
200 women with preterm prelabour ruptured membranes or undergoing preterm CS
|
The LBC (the unit of measurement is number of lamellar bodies counted per microliter of amniotic fluid) will be determined using the platelet channels on the Hematology Flow Cytometer.
Altri nomi:
A fetal pulmonary artery Doppler will be performed using color Doppler ultrasound.
Doppler flow velocity measurements, including systolic/diastolic ratio, pulsatility index, resistance index, and acceleration-time/ejection-time ratio using spectral Doppler ultrasound.
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
---|---|---|
Respiratory distress syndrome (RDS)
Lasso di tempo: 1 day after delivery
|
RDS will be diagnosed clinically by the presence of tachypnea, working respiratory muscles, expiratory grunt, and chest x-ray.
|
1 day after delivery
|
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
---|---|---|
Need for incubation
Lasso di tempo: 1 day after delivery
|
It will be recorded if the pediatrician decides to incubate the neonate.
The reason for incubation e.g.
ventilation, hypoxia, ischemia will be recorded.
|
1 day after delivery
|
Collaboratori e investigatori
Sponsor
Pubblicazioni e link utili
Pubblicazioni generali
- AVERY ME, MEAD J. Surface properties in relation to atelectasis and hyaline membrane disease. AMA J Dis Child. 1959 May;97(5, Part 1):517-23. doi: 10.1001/archpedi.1959.02070010519001. No abstract available.
- Dubin SB. Characterization of amniotic fluid lamellar bodies by resistive-pulse counting: relationship to measures of fetal lung maturity. Clin Chem. 1989 Apr;35(4):612-6.
- Neerhof MG, Dohnal JC, Ashwood ER, Lee IS, Anceschi MM. Lamellar body counts: a consensus on protocol. Obstet Gynecol. 2001 Feb;97(2):318-20. doi: 10.1016/s0029-7844(00)01134-0.
Studiare le date dei record
Studia le date principali
Inizio studio
Completamento primario (Anticipato)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Stima)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Stima)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
- preterm 1
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .