Cette page a été traduite automatiquement et l'exactitude de la traduction n'est pas garantie. Veuillez vous référer au version anglaise pour un texte source.

Spanish Prospective Registry of Hydra THV for Transcatheter Aortic Valve Implantation (HYSPANIA)

4 août 2026 mis à jour par: Fundación EPIC

This study is designed to evaluate the success rate of transfemoral implantation of the Hydra THV biological aortic valve prosthesis in patients with severe symptomatic aortic stenosis. The device is used in accordance with its Instructions for Use as a CE-marked transcatheter heart valve system.

The study will assess procedural success, device performance, and early clinical outcomes following implantation. Patients undergoing transcatheter aortic valve replacement (TAVR) via the transfemoral approach will be followed to evaluate safety and effectiveness outcomes, including short- and mid-term clinical follow-up.

Aperçu de l'étude

Description détaillée

This study is designed to evaluate the success rate of transfemoral implantation of the Hydra THV biological aortic valve prosthesis in patients with severe symptomatic aortic stenosis. The device is used in accordance with its Instructions for Use as a CE-marked transcatheter heart valve system.

The study will assess procedural success, device performance, and early clinical outcomes following implantation. Patients undergoing transcatheter aortic valve replacement (TAVR) via the transfemoral approach will be followed to evaluate safety and effectiveness outcomes, including short- and mid-term clinical follow-up.

Type d'étude

Observationnel

Inscription (Estimé)

100

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Coordonnées de l'étude

Sauvegarde des contacts de l'étude

Lieux d'étude

      • Fuencarral-El Pardo, Espagne, 28046
        • Recrutement
        • Hospital Universitario La Paz
      • Santiago de Compostela, Espagne, 15706
        • Recrutement
        • Hospital Clínico Universitario de Santiago

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

  • Adulte
  • Adulte plus âgé

Accepte les volontaires sains

Non

Méthode d'échantillonnage

Échantillon non probabiliste

Population étudiée

The Hydra THV valve is approved for the treatment of patients with aortic stenosis. Basically, patients will be eligible for inclusion in this clinical scenario, according to the instructions for use of the device.

La description

Inclusion Criteria:

Participants who meet ALL of the following conditions will be included:

  • Age ≥ 18 years and;
  • Severe aortic stenosis with indication for aortic valve replacement in which a Hydra THV device is implanted according to the instructions for use; and
  • Signed informed consent.

Exclusion Criteria:

Patients who do NOT meet ANY of the following conditions will be included:

  • Express refusal by the participant to participate in the study.
  • Aortic stenosis patients who are not candidates for Hydra THV device implantation or in whom implantation of this device is performed for an indication other than aortic stenosis (especially pure native aortic valve insufficiency). Patients in whom the Hydra THV device is implanted to treat patients with degenerated aortic bioprostheses may be included in the study.
  • Participants in randomised clinical trials who have not reached the research endpoint.
  • Pregnant and/or breastfeeding women.

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

Cohortes et interventions

Groupe / Cohorte
Intervention / Traitement
Hydra Transcatheter Heart Valve (THV)
Patients in whom the Hydra THV device is implanted to treat patients with degenerated aortic bioprostheses.

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
Assessment of the success rate of implantation
Délai: 7 days

Assessment of the success rate of implantation defined by:

  • Absence of mortality during the procedure or within 24 hours after implantation; and
  • Correct anatomical positioning of a single valve; and
  • Absence of mismatch, defined as effective aortic valve area > 0.85 cm²/m²and;
  • Mean gradient < 20 mm Hg or peak velocity < 3 m/s and;
  • Absence of moderate or severe aortic regurgitation
7 days
Success of the procedure
Délai: 7 days
Composite outcome measures defined as a the absence of intra-procedural mortality or complications during implantation, such as: failure to implant the valve at the annulus level, the need to implant more than one valve (valve-in-valve implantation or implantation of a second valve due to embolisation of the first) or surgical intervention on the aortic valve due to severe aortic insufficiency or complications of the procedure.
7 days

Mesures de résultats secondaires

Mesure des résultats
Description de la mesure
Délai
Mortalité cardiovasculaire
Délai: 12 mois
Incidence de la mortalité cardiovasculaire
12 mois
All cause mortality
Délai: 7 days
Incidence of all cause mortality
7 days
All cause mortality
Délai: 30 days
Incidence of all cause mortality
30 days
All cause mortality
Délai: 12 months
Incidence of all cause mortality
12 months
Cardiovascular mortality
Délai: 7 days
Incidence of cardiovascular mortality
7 days
Cardiovascular mortality
Délai: 30 days
Incidence of cardiovascular mortality
30 days
Stroke
Délai: 7 days
Incidence of Stroke
7 days
Stroke
Délai: 30 days
Incidence of Stroke
30 days
Stroke
Délai: 12 months
Incidence of Stroke
12 months
Stroke with disabling
Délai: 7 days
Incidence of Stroke with disabling
7 days
Stroke with disabling
Délai: 30 days
Incidence of Stroke with disabling
30 days
Stroke with disabling
Délai: 12 months
Incidence of Stroke with disabling
12 months
Stroke with non disabling
Délai: 7 days
Incidence of Stroke with non disabling
7 days
Stroke with non disabling
Délai: 30 days
Incidence of Stroke with non disabling
30 days
Stroke with non disabling
Délai: 12 months
Incidence of Stroke with non disabling
12 months
Acute myocardial infarction
Délai: 7 days
Incidence of acute myocardial infarction
7 days
Acute myocardial infarction
Délai: 30 days
Incidence of acute myocardial infarction
30 days
Acute myocardial infarction
Délai: 12 months
Incidence of acute myocardial infarction
12 months
Coronary occlusion
Délai: 7days
Incidence of coronary occlusion
7days
Coronary occlusion
Délai: 30 days
Incidence of coronary occlusion
30 days
Coronary occlusion
Délai: 12 months
Incidence of coronary occlusion
12 months
Haemorrhagic complications
Délai: 7 days
Incidence of haemorrhagic complications
7 days
Haemorrhagic complications
Délai: 30 days
Incidence of haemorrhagic complications
30 days
Haemorrhagic complications
Délai: 12 months
Incidence of haemorrhagic complications
12 months
Vascular complications
Délai: 7 days
Incidence of vascular complications
7 days
Vascular complications
Délai: 30 days
Incidence of vascular complications
30 days
Vascular complications
Délai: 12 Months
Incidence of vascular complications
12 Months
Acute renal failure
Délai: 7 days
Incidence of Acute renal failure
7 days
Acute renal failure
Délai: 30 days
Incidence of Acute renal failure
30 days
Acute renal failure
Délai: 12 months
Incidence of Acute renal failure
12 months
Conduction disturbances
Délai: 7 days
Incidence of conduction disturbances
7 days
Conduction disturbances
Délai: 30 days
Incidence of conduction disturbances
30 days
Conduction disturbances
Délai: 12 months
Incidence of conduction disturbances
12 months
Arrhythmias
Délai: 7 days
Incidence of Arrhythmias
7 days
Arrhythmias
Délai: 30 days
Incidence of Arrhythmias
30 days
Arrhythmias
Délai: 12 months
Incidence of Arrhythmias
12 months
Implantation of a new permanent pacemaker
Délai: 7 days
Incidence of Implantation of a new permanent pacemaker
7 days
Implantation of a new permanent pacemaker
Délai: 30 days
Incidence of Implantation of a new permanent pacemaker
30 days
Implantation of a new permanent pacemaker
Délai: 12 months
Incidence of Implantation of a new permanent pacemaker
12 months
Combined safety event at 30 days defined by Valve Academic Research Consortium 3 (VARC-3) criteria
Délai: 30 days
Proportion of patients with freedom from: all-cause mortality, all stroke, VARC type 2-4 bleeding, major vascular, access-related, or cardiac structural complication, acute kidney injury stage 3 or 4, moderate or severe aortic regurgitation, new permanent pacemaker due to procedure related conduction abnormalities, surgery or intervention related to the device.
30 days
New York Heart Association (NYHA)
Délai: 7 days
Proportion of patients with modification of NYHA, before the procedure and its modification after the procedure
7 days
New York Heart Association (NYHA)
Délai: 30 days
Proportion of patients with modification of NYHA, before the procedure and its modification after the procedure
30 days
New York Heart Association (NYHA)
Délai: 12 months
Proportion of patients with modification of NYHA before the procedure and its modification after the procedure
12 months
Echocardiographic Valve Dysfunction Assessment
Délai: 7 days

Composite outcome measures defined as a: Effective aortic valve area and Mean transvalvular gradient and Degree of aortic regurgitation and Left ventricular ejection fraction (LVEF) and Pulmonary systolic pressure. Any of the following findings are considered evidence of dysfunction:

Mean gradient ≥ 20 mmHg. Effective aortic valve area ≤ 0.9-1.1 cm2/m2. Moderate or severe para-valvular insufficiency

7 days
Echocardiographic Valve Dysfunction Assessment
Délai: 30 days

Composite outcome measures defined as a: Effective aortic valve area and Mean transvalvular gradient and Degree of aortic regurgitation and Left ventricular ejection fraction (LVEF) and Pulmonary systolic pressure. Any of the following findings are considered evidence of dysfunction:

Mean gradient ≥ 20 mmHg. Effective aortic valve area ≤ 0.9-1.1 cm2/m2. Moderate or severe para-valvular insufficiency

30 days
Echocardiographic Valve Dysfunction Assessment
Délai: 12 months

Composite outcome measures defined as a: Effective aortic valve area and Mean transvalvular gradient and Degree of aortic regurgitation and Left ventricular ejection fraction (LVEF) and Pulmonary systolic pressure. Any of the following findings are considered evidence of dysfunction:

Mean gradient ≥ 20 mmHg. Effective aortic valve area ≤ 0.9-1.1 cm2/m2. Moderate or severe para-valvular insufficiency

12 months

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Parrainer

Publications et liens utiles

La personne responsable de la saisie des informations sur l'étude fournit volontairement ces publications. Il peut s'agir de tout ce qui concerne l'étude.

Publications générales

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Réel)

7 juillet 2026

Achèvement primaire (Estimé)

1 janvier 2029

Achèvement de l'étude (Estimé)

1 février 2029

Dates d'inscription aux études

Première soumission

27 avril 2026

Première soumission répondant aux critères de contrôle qualité

27 avril 2026

Première publication (Réel)

5 mai 2026

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

5 août 2026

Dernière mise à jour soumise répondant aux critères de contrôle qualité

4 août 2026

Dernière vérification

1 août 2026

Plus d'information

Termes liés à cette étude

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Non

Étudie un produit d'appareil réglementé par la FDA américaine

Non

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

S'abonner