Comparison of 3 Tesla MRI to 7 Tesla MRI for Evaluation of Prostate Suspicion Lesions
A comparison of 3 Tesla MRI to 7 Tesla MRI for Evaluation of Prostate Suspicious Lesions.
Assess the added diagnostic value of ultra-high-field (7T) MRI over the current clinical standard (3T MRI) in detecting and characterizing suspicious prostate lesions. Evaluate whether dynamic deuterated glucose-enhanced imaging at 7T can offer improved contrast without the use of gadolinium-based agents.
Aperçu de l'étude
Statut
Les conditions
Intervention / Traitement
Description détaillée
Type d'étude
Inscription (Estimé)
Phase
- N'est pas applicable
Contacts et emplacements
Coordonnées de l'étude
- Nom: Shai Efrati, MD
- Numéro de téléphone: 972549212866
- E-mail: efratishai@outlook.com
Lieux d'étude
-
-
Israel
-
Zrifin, Israel, Israël, 70300
- The Sagol Center for Hyperbaric Medicine and Research Shamir Medical Center (Assaf Harofeh)
-
Contact:
- Shai Efrati, Prof
- Numéro de téléphone: +972-8-9779393
- E-mail: efratishai@outlook.com
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
- Adulte
- Adulte plus âgé
Accepte les volontaires sains
La description
Inclusion Criteria:
- male patients referred for clinical 3T prostate MRI at Shamir Medical Center
- male patients who consent to undergo an additional 7T scan at the Weizmann Institute.
Exclusion Criteria:
- Contraindications to MRI (e.g., non-compatible implants, pacemakers, severe claustrophobia)
- diabetes mellitus
- glucose intolerance
- hyperglycemia
- hyperlactatemia
- chronic kidney disease (GFR <45 mL/min/1.73 m2).
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Diagnostique
- Répartition: N / A
- Modèle interventionnel: Affectation à un seul groupe
- Masquage: Aucun (étiquette ouverte)
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
|---|---|
|
Expérimental: 3 Tesla (3T) versus 7 Tesla (7T) MRI in the assessment of suspicious prostate lesions
Each participant serves as their own control, undergoing both 3T and 7T MRI scans.
|
Imaging protocols will include multiparametric sequences at both field strengths, with the addition of high-resolution anatomical and optional dynamic glucose-enhanced imaging at 7T.
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
ROC analysis of diagnostic performance: 3T versus 7T MRI
Délai: Assessed at the time of MRI acquisition during the study imaging visit.
|
ROC analysis (Receiver Operating Characteristic analysis) - A statistical method used to evaluate and compare diagnostic accuracy.
It examines how well a test distinguishes between diseased and non-diseased cases across different thresholds.
|
Assessed at the time of MRI acquisition during the study imaging visit.
|
|
Sensitivity and Specificity of diagnostic performance: 3T versus 7T MRI
Délai: Assessed at the time of MRI acquisition during the study imaging visit.
|
Sensitivity - The ability of the MRI to correctly identify patients who truly have disease (true positive rate). High sensitivity means fewer missed cases. Specificity - The ability of the MRI to correctly identify patients who do not have disease (true negative rate). High specificity means fewer false alarms or false positives. |
Assessed at the time of MRI acquisition during the study imaging visit.
|
|
Lesion conspicuity of diagnostic performance: 3T versus 7T MRI
Délai: Assessed at the time of MRI acquisition during the study imaging visit.
|
How clearly and visibly an abnormal lesion can be seen on MRI images compared with surrounding tissue.
Higher conspicuity generally makes lesions easier to detect and characterize.
|
Assessed at the time of MRI acquisition during the study imaging visit.
|
|
PI-RADS classification - The Prostate Imaging Reporting and Data System: 3T versus 7T MRI
Délai: Assessed at the time of MRI acquisition during the study imaging visit.
|
a standardized scoring system used in prostate MRI to estimate the likelihood of clinically significant prostate cancer.
Scores range from 1 (very low likelihood) to 5 (very high likelihood).
|
Assessed at the time of MRI acquisition during the study imaging visit.
|
|
Quantitative imaging metrics of diagnostic performance: 3T versus 7T MRI
Délai: Assessed at the time of MRI acquisition during the study imaging visit.
|
Numerical measurements derived from MRI images, such as lesion size, signal intensity, contrast ratios, diffusion values (e.g., ADC), or texture features, used to objectively compare imaging performance.
|
Assessed at the time of MRI acquisition during the study imaging visit.
|
Collaborateurs et enquêteurs
Parrainer
Les enquêteurs
- Chercheur principal: Shai Efrati, Asaf-Harofhe MC
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Estimé)
Achèvement primaire (Estimé)
Achèvement de l'étude (Estimé)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .