- ICH GCP
- USA klinikai vizsgálatok nyilvántartása
- Klinikai vizsgálat NCT03350763
Biliary Drainage Preceding Possible Pancreaticoduodenectomy. Are Self-expandable Metallic Stents (SEMS) Superior to Plastic Stents?
This study looks in to the rate of biliary stent dysfunction for plastic and metallic stents in patients who need biliary drainage due to a tumor in pancreas before possible pancreaticoduodenectomy. Complications related to the biliary decompression, and possible post-surgical complications in all patients are also recorded.
This trial aims to confirm whether metallic biliary stents really are superior to plastic stents as some previous studies suggest. Specific patient groups are also evaluated individually to see, whether patients with ongoing cholangitis at the time of diagnosis or patients receiving neoadjuvant treatments have less stent dysfunction cases and complications with metallic stents than with plastic stents.
A tanulmány áttekintése
Állapot
Körülmények
Beavatkozás / kezelés
Tanulmány típusa
Fázis
- Nem alkalmazható
Kapcsolatok és helyek
Tanulmányi helyek
-
-
Uusimaa
-
Helsinki, Uusimaa, Finnország, 00029
- Helsinki University Hospital
-
-
Részvételi kritériumok
Jogosultsági kritériumok
Tanulmányozható életkorok
Egészséges önkénteseket fogad
Tanulmányozható nemek
Leírás
Inclusion Criteria:
- Resectable tumor of the head of the pancreas
- Elevated serum bilirubin levels
- Radiologically visible dilatation of the biliary system
Exclusion Criteria:
- Distant metastasis
- Inoperable tumor or other reason, why the patient is unfit for surgery
Tanulási terv
Hogyan készül a tanulmány?
Tervezési részletek
- Elsődleges cél: Kezelés
- Kiosztás: Véletlenszerűsített
- Beavatkozó modell: Párhuzamos hozzárendelés
- Maszkolás: Nincs (Open Label)
Fegyverek és beavatkozások
Résztvevő csoport / kar |
Beavatkozás / kezelés |
|---|---|
|
Kísérleti: Plastic biliary stent
A plastic (ie Tannenbaum 10 Fr) biliary stent is used to achieve biliary decompression
|
Tannenbaum 10 Fr biliary stent
|
|
Kísérleti: Self-expandable metallic biliary stent
A self-expandable metallic biliary stent is used to achieve biliary decompression
|
ie WallFlex biliary RX
|
Mit mér a tanulmány?
Elsődleges eredményintézkedések
Eredménymérő |
Időkeret |
|---|---|
|
Stent failure rate, and need for re-procedure before pancreaticoduodenectomy.
Időkeret: Evaluation at the day of pancreatic surgery
|
Evaluation at the day of pancreatic surgery
|
Másodlagos eredményintézkedések
Eredménymérő |
Időkeret |
|---|---|
|
Other complications related to preoperative biliary decompression, and post-surgical complications
Időkeret: Complication emerged within 120 days from pancreaticoduodenectomy
|
Complication emerged within 120 days from pancreaticoduodenectomy
|
Együttműködők és nyomozók
Szponzor
Nyomozók
- Kutatásvezető: Leena Kylänpää, MD, PhD, Helsinki University Central Hospital
Publikációk és hasznos linkek
Általános kiadványok
- Decker C, Christein JD, Phadnis MA, Wilcox CM, Varadarajulu S. Biliary metal stents are superior to plastic stents for preoperative biliary decompression in pancreatic cancer. Surg Endosc. 2011 Jul;25(7):2364-7. doi: 10.1007/s00464-010-1552-6. Epub 2011 Mar 4.
- Haapamaki C, Seppanen H, Udd M, Juuti A, Halttunen J, Kiviluoto T, Siren J, Mustonen H, Kylanpaa L. Preoperative biliary decompression preceding pancreaticoduodenectomy with plastic or self-expandable metallic stent. Scand J Surg. 2015 Jun;104(2):79-85. doi: 10.1177/1457496914543975. Epub 2014 Jul 15.
- Velanovich V, Kheibek T, Khan M. Relationship of postoperative complications from preoperative biliary stents after pancreaticoduodenectomy. A new cohort analysis and meta-analysis of modern studies. JOP. 2009 Jan 8;10(1):24-9.
Tanulmányi rekorddátumok
Tanulmány főbb dátumok
Tanulmány kezdete (Tényleges)
Elsődleges befejezés (Várható)
A tanulmány befejezése (Várható)
Tanulmányi regisztráció dátumai
Először benyújtva
Először nyújtották be, amely megfelel a minőségbiztosítási kritériumoknak
Első közzététel (Tényleges)
Tanulmányi rekordok frissítései
Utolsó frissítés közzétéve (Tényleges)
Az utolsó frissítés elküldve, amely megfelel a minőségbiztosítási kritériumoknak
Utolsó ellenőrzés
Több információ
A tanulmányhoz kapcsolódó kifejezések
Kulcsszavak
További vonatkozó MeSH feltételek
Egyéb vizsgálati azonosító számok
- HUS/2470/2017
Terv az egyéni résztvevői adatokhoz (IPD)
Tervezi megosztani az egyéni résztvevői adatokat (IPD)?
Gyógyszer- és eszközinformációk, tanulmányi dokumentumok
Egy amerikai FDA által szabályozott gyógyszerkészítményt tanulmányoz
Egy amerikai FDA által szabályozott eszközterméket tanulmányoz
Ezt az információt közvetlenül a clinicaltrials.gov webhelyről szereztük be, változtatás nélkül. Ha bármilyen kérése van vizsgálati adatainak módosítására, eltávolítására vagy frissítésére, kérjük, írjon a következő címre: register@clinicaltrials.gov. Amint a változás bevezetésre kerül a clinicaltrials.gov oldalon, ez a webhelyünkön is automatikusan frissül. .