Questa pagina è stata tradotta automaticamente e l'accuratezza della traduzione non è garantita. Si prega di fare riferimento al Versione inglese per un testo di partenza.

Molecular Imaging Visualization of Tumor Heterogeneity in Non-small Cell Lung Cancer

To assess the potential usefulness of radiogenomics for tumor driving genes heterogeneity in non-small cell lung cancer.

Panoramica dello studio

Descrizione dettagliata

Patients with advanced NSCLC underwent 18F-FDG PET/CT and PET/CT-guided synchronous targeted biopsy of primary and distant metastatic tumors. The LIFEx package was used to extract PET and CT radiomic features from primary and metastatic lesions. The radiomic ROI sites of primary and distant metastatic tumors were point-to-point corresponding to the PET/ CT-guided targeted biopsy sites. Whole exon sequencing of primary and distant metastatic tumor samples obtained by PET/CT-guided targeted biopsy was used to get genomic data of primary and distant metastatic tumor. Predictive radiogenomics models were established and validation.

Tipo di studio

Interventistico

Iscrizione (Anticipato)

150

Fase

  • Non applicabile

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Luoghi di studio

    • Fujian
      • XiaMen, Fujian, Cina, 0086-361000
        • Reclutamento
        • First Affiliated Hospital of Xiamen University
        • Contatto:

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

Da 18 anni a 90 anni (Adulto, Adulto più anziano)

Accetta volontari sani

No

Sessi ammissibili allo studio

Tutto

Descrizione

Criteria: Inclusion Criteria:

  • (i) adult patients (aged 18 years or order);
  • (ii) patients with suspected or newly diagnosed or previously treated malignant tumors (supporting evidence may include magnetic resonance imaging (MRI), CT, tumor markers and pathology report);
  • (iii) patients who had scheduled both 18F-FDG PET/CT scans and PET/CT guided biopsy;
  • (iv) patients who were able to provide informed consent (signed by participant, parent or legal representative) and assent according to the guidelines of the Clinical Research Ethics Committee.

Exclusion Criteria:

  • (i) patients with non-malignant lesions;
  • (ii) patients with pregnancy;
  • (iii) the inability or unwillingness of the research participant, parent or legal representative to provide written informed consent.

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

  • Scopo principale: Diagnostico
  • Assegnazione: N / A
  • Modello interventistico: Assegnazione di gruppo singolo
  • Mascheramento: Nessuno (etichetta aperta)

Armi e interventi

Gruppo di partecipanti / Arm
Intervento / Trattamento
Sperimentale: 8F-FDG PET/CT and PET/CT-guide targeted biopsy
Each subject receive a single intravenous injection of 18F-FDG PET/CT and PET/CT-guide targeted biopsy within the specified time.
Each subject receive a single intravenous injection of 18F-FDG PET/CT and PET/CT-guide targeted biopsy within the specified time

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Radiomic feature selection and model establishment
Lasso di tempo: 3 years
In this study, the investigators first selected the features with significant differences between genes mutant and wild type in the training set using the Mann-Whitney U test, obtaining a total of 53 features with p value < 0.05. Then, the least absolute shrinkage and selection operator (LASSO) algorithm was used to select the optimal predictive features among the 53 selected in the training set. The LASSO algorithm adds a L1 regularization term to a least square algorithm to avoid overfitting. A prediction model was established by logistic regression, and the radiomics signature score (rad-score) for each participant was calculated based on the selected discriminating radiomic features. The model performance was tested in the validation set. The receiver operating characteristic (ROC) curve and the area under the curve (AUC) were used to evaluate the model performance in the training and validation sets.
3 years

Misure di risultato secondarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Genes mutation detection
Lasso di tempo: 30 days
Genes mutation detection was performed on histological specimens obtained by surgical resection or puncture. Genes mutation detection was conducted by the examination of the whole-exome sequencing. The whole-exome sequencing is performed by the Novogene company (www.novogene.com). If any genes mutation in the whole-exome sequencing was detected, the tumor was considered genes mutant. Otherwise, the tumor was classified as no mutant of genes type.
30 days
Image acquisition
Lasso di tempo: 30 days
The imaging acquisition protocol was established following the Image Biomarker Standardisation Initiative (IBSI) reporting guidelines. All the details of the procedures are provided in the electronic supplementary material. 18F-FDG PET/CT (Discovery MI, GE Healthcare, Milwaukee, WI, USA) examination was performed within 1 month before treatment. Briefly, 18F-FDG PET/CT images were acquired 60 ± 5 min after 18F-FDG injection in accordance with the European Association of Nuclear Medicine (EANM) guidelines, version 1.0 (version 2.0 from February 2015). A 3D LOR reconstruction algorithm was used to reconstruct the PET images. The attenuation correction of PET images was carried out with CT data, and the corrected PET images were fused with CT images.
30 days
Radiomic feature extraction
Lasso di tempo: 30 days
The LIFEx package (version 4.00, http://www.lifexsoft.org) was used to extract the texture features of PET/CT images of lesions in the same VOI. The PET/CT image of the patient in the DICOM format was imported into the software. Two experienced PET/CT diagnostic physicians semi-automatically delineated the region of interest of the target lesion using a threshold of 40% of the maximum standardized uptake value (SUVmax). Then, the software program automatically calculates and extracts 47 PET radiomic features and 45 CT radiomic features.
30 days

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Investigatori

  • Investigatore principale: Long Sun, PhD, The First Affiliated Hospital of Xiamen University

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio (Effettivo)

1 ottobre 2019

Completamento primario (Anticipato)

1 ottobre 2022

Completamento dello studio (Anticipato)

1 ottobre 2022

Date di iscrizione allo studio

Primo inviato

30 luglio 2020

Primo inviato che soddisfa i criteri di controllo qualità

11 settembre 2020

Primo Inserito (Effettivo)

17 settembre 2020

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

17 settembre 2020

Ultimo aggiornamento inviato che soddisfa i criteri QC

11 settembre 2020

Ultimo verificato

1 luglio 2020

Maggiori informazioni

Termini relativi a questo studio

Piano per i dati dei singoli partecipanti (IPD)

Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?

NO

Informazioni su farmaci e dispositivi, documenti di studio

Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti

No

Studia un dispositivo regolamentato dalla FDA degli Stati Uniti

No

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .

Prove cliniche su NSCLC

Prove cliniche su 18F-FDG PET/CT and PET/CT-guide targeted biopsy in another group of participants

Sottoscrivi