Digital Wavefront Sensing (DWS)
Reproducibility and Comparison of Digital Wavefront Sensing With Conventional Shack-Hartmann Wavefront Sensing: an Explorative Study
Panoramica dello studio
Stato
Intervento / Trattamento
Descrizione dettagliata
H-OCT will be tested in this study for its suitability for the qualitative investigation of aberrometry. We aim to achieve a digital equivalent for wavefront calculation of the widespread analog procedure commonly used with conventional wavefront-aberrometers. The results will be compared with those from a conventional analog wavefront calculation method.
In the course of this pilot study, 20 eyes of phakic and 10 eyes of pseudophakic subjects with suspected higher order aberrations will be examined using H-OCT.
Tipo di studio
Iscrizione (Anticipato)
Fase
- Non applicabile
Contatti e Sedi
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Descrizione
Inclusion Criteria:
- Informed consent
- Men and women aged between 18 and 85 years
- Normal ophthalmic findings except refractive errors or suspected higher order aberrations
- Normal findings in the medical history unless the investigator considers an abnormality to be clinically irrelevant
Exclusion Criteria:
- Hyperopia > +6 Dpt. and Myopia < -6 Dpt.
- Known ophthalmic diseases such as age related macular degeneration, diabetic retinopathy, glaucoma, retinal detachment or previous ocular trauma and surgeries except cataract extraction
- Participation in a clinical trial in the previous 3 weeks
- Presence of any abnormalities preventing reliable measurements as judged by the investigator
- Pregnancy, planned pregnancy or lactating
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Scienza basilare
- Assegnazione: N / A
- Modello interventistico: Assegnazione di gruppo singolo
- Mascheramento: Nessuno (etichetta aperta)
Armi e interventi
Gruppo di partecipanti / Arm |
Intervento / Trattamento |
|---|---|
|
Sperimentale: Holographic optical coherence tomography
Healthy phakic participants
|
Descriptive wavefront analysis with holographic optical coherence tomography
Altri nomi:
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Qualitative description of lower order aberrations (LOA)
Lasso di tempo: 14 +/- 3 days
|
Zernike terms, RMS-error, Strehl ratio
|
14 +/- 3 days
|
|
Qualitative description of higher order aberrations (HOA)
Lasso di tempo: 14 +/- 3 days
|
Zernike terms, root mean square error , Strehl ratio |
14 +/- 3 days
|
Collaboratori e investigatori
Sponsor
Investigatori
- Investigatore principale: Rainer Leitgeb, Prof., Meidcal University of Vienna
Pubblicazioni e link utili
Pubblicazioni generali
- Kumar A, Drexler W, Leitgeb RA. Subaperture correlation based digital adaptive optics for full field optical coherence tomography. Opt Express. 2013 May 6;21(9):10850-66. doi: 10.1364/OE.21.010850.
- Liang J, Grimm B, Goelz S, Bille JF. Objective measurement of wave aberrations of the human eye with the use of a Hartmann-Shack wave-front sensor. J Opt Soc Am A Opt Image Sci Vis. 1994 Jul;11(7):1949-57. doi: 10.1364/josaa.11.001949.
- Kumar A, Wurster LM, Salas M, Ginner L, Drexler W, Leitgeb RA. In-vivo digital wavefront sensing using swept source OCT. Biomed Opt Express. 2017 Jun 21;8(7):3369-3382. doi: 10.1364/BOE.8.003369. eCollection 2017 Jul 1.
Studiare le date dei record
Studia le date principali
Inizio studio (Anticipato)
Completamento primario (Anticipato)
Completamento dello studio (Anticipato)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
- OPHT-100419
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .
Prove cliniche su Holographic optical coherence tomography
-
Medical University of ViennaReclutamento