Safety and Feasibility of a Novel Device for Assessing Respiratory Function in Children
Safety and Feasibility of Utilizing a Novel Wearable Device (Leo) for Assessing Respiratory Function in Children With Respiratory Condition - a Pilot Early Phase Clinical Study
This is an early phase pilot study designed to test the safety and feasibility of using a novel, wireless, wearable device (Leo) for assessing respiratory parameters (lung volume, respiration rate, heart rate and indices related to tidal breathing flow volume loop) in children with respiratory condition (such as asthma).
There is no product currently on the market that is comparable to this novel Leo device
The study consists of a single visit to evaluate the feasibility and safety of using the Leo device on 20 children with clinically stable asthma.
Stable asthmatic children between the age of 3 and 6, inclusive, will be recruited.
There will be no disease-specific intervention, nor changes to the participant's care management program for their asthma.
Panoramica dello studio
Tipo di studio
Iscrizione (Effettivo)
Fase
- Non applicabile
Contatti e Sedi
Luoghi di studio
-
-
Colorado
-
Aurora, Colorado, Stati Uniti, 80045
- Children's Colorado Hospital
-
-
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Descrizione
Inclusion Criteria:
- Children aged ≥3 years old and ≤18 years old at time of consent
- Children with a legal guardian able to sign consent for study participation
- Children and caregivers able to read and understand English or Spanish
- Investigator confirmation for diagnosis of clinically stable respiratory condition, such as clinically diagnosed asthma
- Children who are able to follow instructions and complete oscillometry and tidal breathing tasks
Exclusion Criteria:
- - Children <3 and >18 years of age
- Adults (age ≥ 18 years)
- Children with complex medical conditions which may hinder their ability to complete protocol assessments
- Children who do not have a legal guardian to sign informed consent form
- Children with an active skin condition involving the area on the chest wall where the Leo device will be attached. E.g. inflamed and/or infected eczema or other skin conditions involving the anterior chest wall at the time of recruitment
- Child is determined not eligible by the assessment of the PI
- Fever within the 4 weeks prior to enrollment
- Children with any implanted medical devices, E.g. cardiac pacemaker
- Children with any history of known allergic reaction to adhesives or hydrogels, as the ones used with the Leo device
- Children who have taken a bronchodilator in the last 8-24 hours prior to study visit, depending on the type of medication.
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Fattibilità del dispositivo
- Assegnazione: N / A
- Modello interventistico: Assegnazione di gruppo singolo
- Mascheramento: Nessuno (etichetta aperta)
Armi e interventi
Gruppo di partecipanti / Arm |
Intervento / Trattamento |
|---|---|
|
Altro: Oscillometry + Pneumotach Procedure with Leo Device measurements
All patients will undergo oscillometry procedure, followed by pneumotach procedure to measure tidal volume in different sitting positions. The Leo device will be worn throughout both procedures to measure the chest electrical impedance and compare against pneumotach measurements. Oscillometry and pneumotach are part of standard of care. |
Children's respiratory flow and volume measurements will be continuously recorded using the Leo device during oscillometry and pneumotach procedures.
Altri nomi:
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Slow vital capacity from Leo device
Lasso di tempo: Baseline
|
Agreement and correlation in the lung function parameters derived using the respiratory impedance signals recorded from Leo device, compared to the pneumotachograph (PNT) device.
The PNT device readings will be considered the standard of care, and compared against the Leo device to evaluate for device feasibility.
This will be done before and after administration of bronchodilator.
|
Baseline
|
|
Slow vital capacity from PNT device
Lasso di tempo: Baseline
|
Agreement and correlation in the lung function parameters derived using the respiratory impedance signals recorded from Leo device, compared to the pneumotachograph (PNT) device.
The PNT device readings will be considered the standard of care, and compared against the Leo device to evaluate for device feasibility.
This will be done before and after administration of bronchodilator.
|
Baseline
|
|
Tidal breathing from Leo device
Lasso di tempo: Baseline
|
Agreement and correlation in tidal breathing parameters between Leo and the pneumotachograph (PNT) device.
The PNT device parameters are considered standard of care, and will be compared against Leo device to evaluate for device feasibility.
This will be done before and after administration of bronchodilator.
|
Baseline
|
|
Tidal breathing from PNT device
Lasso di tempo: Baseline
|
Agreement and correlation in tidal breathing parameters between Leo and the pneumotachograph (PNT) device.
The PNT device parameters are considered standard of care, and will be compared against Leo device to evaluate for device feasibility.
This will be done before and after administration of bronchodilator.
|
Baseline
|
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Usability
Lasso di tempo: Baseline
|
Clinician, patient and caregiver usability feedback on the use of the Leo device through an IRB approved participant questionnaire.
|
Baseline
|
Collaboratori e investigatori
Sponsor
Investigatori
- Investigatore principale: Andrew Liu, Children's Hospital Colorado
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Completamento primario (Effettivo)
Completamento dello studio (Effettivo)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
- OTH-21-02-01
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Descrizione del piano IPD
Tipo di informazioni di supporto alla condivisione IPD
- Protocollo di studio
- Piano di analisi statistica (SAP)
- Modulo di consenso informato (ICF)
- Relazione sullo studio clinico (CSR)
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
prodotto fabbricato ed esportato dagli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .
Prove cliniche su Leo device
-
LEO PharmaCompletatoCheratosi attinicaStati Uniti
-
LEO PharmaCompletato
-
LEO PharmaCompletato
-
LEO PharmaCompletatoEczema cronico della manoGermania
-
LEO PharmaCompletato
-
LEO PharmaCompletatoDermatite atopicaRegno Unito
-
LEO PharmaTerminatoLupus eritematoso discoideStati Uniti, Francia, Germania, Danimarca
-
LEO PharmaCompletato
-
LEO PharmaCompletatoEczema cronico della manoStati Uniti, Germania, Danimarca
-
LEO PharmaCompletato