Human papillomavirus 16 (HPV 16) and HPV 18 antibody responses measured by pseudovirus neutralization and competitive Luminex assays in a two- versus three-dose HPV vaccine trial

Mel Krajden, Darrel Cook, Amanda Yu, Ron Chow, Wendy Mei, Shelly McNeil, Deborah Money, Marc Dionne, Karuna P Karunakaran, Joel M Palefsky, Simon Dobson, Gina Ogilvie, Martin Petric, Mel Krajden, Darrel Cook, Amanda Yu, Ron Chow, Wendy Mei, Shelly McNeil, Deborah Money, Marc Dionne, Karuna P Karunakaran, Joel M Palefsky, Simon Dobson, Gina Ogilvie, Martin Petric

Abstract

Human papillomavirus 16 (HPV 16) and HPV 18 antibody responses in a 2- versus 3-dose HPV vaccine (Gardasil) trial were measured by a pseudovirus neutralizing antibody (PsV NAb) assay and by the Merck competitive Luminex immunoassay (cLIA). Eight hundred twenty-four female subjects assigned to three dosing regimens (group 1, 9 to 13 years old; 2 doses, months 0 and 6 [n = 259]; group 2, 9 to 13 years old; 3 doses, months 0, 2, and 6 [n = 260]; group 3, 16 to 26 years old; 3 doses, months 0, 2, and 6 [n = 305]) had postvaccine responses assessed 1 month after the last dose. Of 791 subjects with baseline and 7-month sera, 15 (1.9%) and 9 (1.1%) were baseline seropositive for HPV 16 and HPV 18, respectively. All baseline-seronegative vaccinees seroconverted to both HPV 16 and HPV 18. Mean anti-HPV 16 levels were similar for groups 1 and 2 (for PsV NAb, P = 0.675; for cLIA, P = 0.874), and levels for both groups 1 and 2 were approximately 2-fold higher than that for group 3 (for PsV NAb and cLIA, P < 0.001). Mean anti-HPV 18 levels were approximately 1.4-fold lower in group 1 than in group 2 (for PsV, NAb P = 0.013; for cLIA, P = 0.001), and levels for both groups 1 and 2 were approximately 2.0- to 2.5-fold higher than that for group 3 (for PsV NAb and cLIA, P < 0.001). Pearson correlation coefficients for the assays were 0.672 for HPV 16 and 0.905 for HPV 18. Most of the discordant results were observed at lower cLIA signals. These results suggest that the PsV NAb assay could be a suitable alternative to cLIA for the measurement of postvaccine antibody responses.

Figures

FIG. 1.
FIG. 1.
Distribution of subjects.
FIG. 2.
FIG. 2.
HPV 16 antibody responses at 7 months.
FIG. 3.
FIG. 3.
HPV 18 antibody responses at 7 months.
FIG. 4.
FIG. 4.
HPV 16 PsV NAb assay (GMT) versus Merck cLIA (ln) correlation at 7 months (r2 = 0.672).
FIG. 5.
FIG. 5.
HPV 18 PsV NAb assay (GMT) versus Merck cLIA (ln) correlation at 7 months (r2 = 0.905).

Source: PubMed

3
Sottoscrivi