Comparison of forced-air warming and electric heating pad for maintenance of body temperature during total knee replacement

V Ng, A Lai, V Ho, V Ng, A Lai, V Ho

Abstract

We conducted a randomised controlled trial to compare the efficacy of forced-air warming (Bair Hugger(trade mark), Augustine Medical model 500/OR, Prairie, MN) with that of an electric heating pad (Operatherm 202, KanMed, Sweden) for maintenance of intra-operative body temperature in 60 patients undergoing total knee replacement under combined spinal-epidural anaesthesia. Intra-operative tympanic and rectal temperatures and verbal analogue score for thermal comfort were recorded. There were no differences in any measurements between the two groups, with mean (SD) final rectal temperatures of 36.8 (0.4) degrees C with forced-air warming and 36.9 (0.4) degrees C with the electric pad. The heating pad is as effective as forced-air warming for maintenance of intra-operative body temperature.

Figures

Figure 1
Figure 1
Rectal temperature in patients warmed with either forced‐air (top) or heating pad (bottom) during total knee replacement. Values are mean (95% CI). Time 0 refers to the first rectal temperatre after insertion and equilibration of the rectal temperature probe.
Figure 2
Figure 2
Verbal analogue score (VAS) for thermal comfort in patients warmed with either forced‐air (top) or heating pad (bottom) during total knee replacement. Values are mean (95% CI). Initial VAS refers to that on transfer to the operating table.

References

    1. Frank SM, Fleisher LA, Breslow MJ, et al. Perioperative maintenance of normothermia reduces the incidence of morbid cardiac events. A randomized clinical trial. Journal of the American Medical Association 1997; 277: 1127–34.
    1. Kurz A, Sessler DI, Lenhardt R. Perioperative normothermia to reduce the incidence of surgical wound infection and shorten hospitalization. New England Journal of Medicine 1996; 334: 1209–15.
    1. Sessler DI. Mild perioperative hypothermia. New England Journal of Medicine 1997; 336: 1730–7.
    1. Avidan MS, Jones N, Ing R, Khoosal M, Lundgren C, Morrell DF. Convection warmers – not just hot air. Anaesthesia 1997; 52: 1073–6.
    1. Sigg DC, Houlton AJ, Iazzio PA. The potential for increased risk of infection due to the reuse of convective air‐warming/cooling coverlets. Acta Anaesthesiologica Scandinavica 1999; 43: 173–6.
    1. Baker N, King D, Smith EG. Infection control hazards of intraoperative forced air warming. Journal of Hospital Infection 2002; 51: 153–4.
    1. Lee L, Leslie K, Kayak E, Myles PS. Intraoperative patient warming using radiant warming or forced‐air warming during long operations. Anaesthesia and Intensive Care 2004; 32: 358–61.
    1. Lenhardt R. Monitoring and thermal management. Best Practice and Research: Clinical Anaesthesiology 2003; 17: 569–81.
    1. Kamming D, Gardam M, Chung F. Anaesthesia and SARS. British Journal of Anaesthesia 2003; 90: 715–8.
    1. Matsukawa T, Sessler DI, Christensen R, Ozaki M, Schroeder M. Heat flow and distribution during epidural anesthesia. Anesthesiology 1995; 83: 961–7.
    1. Hynson JM, Sessler DI, Moayeri A, McGuire J, Schroeder M. The effects of preinduction warming on temperature and blood pressure during propofol/nitrous oxide anesthesia. Anesthesiology 1993; 79: 219–28.