Control of fluid balance guided by body composition monitoring in patients on peritoneal dialysis (COMPASS): study protocol for a randomized controlled trial

Seon Ha Baek, Kook-Hwan Oh, Sejoong Kim, Dong Ki Kim, Kwon-Wook Joo, Yun Kyu Oh, Byoung Geun Han, Jae Hyun Chang, Wookyung Chung, Yon Su Kim, Ki Young Na, Seon Ha Baek, Kook-Hwan Oh, Sejoong Kim, Dong Ki Kim, Kwon-Wook Joo, Yun Kyu Oh, Byoung Geun Han, Jae Hyun Chang, Wookyung Chung, Yon Su Kim, Ki Young Na

Abstract

Background: The clinical benefits of bioimpedance spectroscopy (BIS)-guided fluid management in patients on hemodialysis have been widely demonstrated. However, no previous reports have evaluated the effect of regular and serial BIS-guided fluid management on the residual renal function (RRF) in patients on peritoneal dialysis (PD). Therefore, we will evaluate the clinical efficacy of BIS-guided fluid management for preserving RRF and protecting cardiovascular events in patients on PD.

Methods/design: This is a multicenter, prospective, randomized controlled trial. A total of 138 participants on PD will be enrolled and randomly assigned to receive either BIS-guided fluid management or fluid management based only on the clinical information for 1 year. The primary outcome is the change in the glomerular filtration rate (GFR) between months 0 and 12 after starting treatment. The secondary outcomes will include GFR at month 12, time to the anuric state (urine volume <100 ml/day), and fatal and nonfatal cardiovascular events during treatment.

Discussion: This is the first clinical trial to investigate the effect of BIS-guided fluid management on RRF and for protecting against cardiovascular events in patients on PD.

Trial registration: Clinical Trials.gov number NCT01887262, June 24, 2013.

Figures

Figure 1
Figure 1
Study algorithm. BCM, body composition monitoring.
Figure 2
Figure 2
Hypervolemia management flow chart. APD, automated peritoneal dialysis; CAPD, continuous ambulatory peritoneal dialysis.
Figure 3
Figure 3
Hypovolemia management flow chart. APD, automated peritoneal dialysis; CAPD, continuous ambulatory peritoneal dialysis.

References

    1. Chen W, Guo LJ, Wang T. Extracellular water/intracellular water is a strong predictor of patient survival in incident peritoneal dialysis patients. Blood Purif. 2007;25:260–266. doi: 10.1159/000101699.
    1. Van Biesen W, Williams JD, Covic AC, Fan S, Claes K, Lichodziejewska-Niemierko M, Verger C, Steiger J, Schoder V, Wabel P, Gauly A, Himmele R, EuroBCM Study Group Fluid status in peritoneal dialysis patients: the European Body Composition Monitoring (EuroBCM) study cohort. PLoS One. 2011;6(2):e17148. doi: 10.1371/journal.pone.0017148.
    1. Jansen MA, Hart AA, Korevaar JC, Dekker FW, Boeschoten EW, Krediet RT. Predictors of the rate of decline of residual renal function in incident dialysis patients. Kidney Int. 2002;62(3):1046–1053. doi: 10.1046/j.1523-1755.2002.00505.x.
    1. Cocchi R, Degli Esposti E, Fabbri A, Lucatello A, Sturani A, Quarello F, Boero R, Bruno M, Dadone C, Favazza A, Scanziani R, Tommasi A, Giangrande A. Prevalence of hypertension in patients on peritoneal dialysis: results of an Italian multicentre study. Nephrol Dial Transplant. 1999;14(6):1536–1540. doi: 10.1093/ndt/14.6.1536.
    1. Davies SJ, Brown EA, Reigel W, Clutterbuck E, Heimburger O, Diaz NV, Mellote GJ, Perez-Contreras J, Scanziani R, D’Auzac C, Kuypers D, Divino Filho JC, EAPOS Group What is the link between poor ultrafiltration and increased mortality in anuric patients on automated peritoneal dialysis? Analysis of data from EAPOS. Perit Dial Int. 2006;26(4):458–465.
    1. Hyun SH, Choi JY, Cho JH, Park SH, Kim CD, Kim YL. Assessment of fluid and nutritional status using multifrequency bioelectrical impedance analysis in peritoneal dialysis patients. Blood Purif. 2014;37(2):152–162. doi: 10.1159/000360272.
    1. Herget-Rosenthal S, von Ostrowski M, Kribben A. Definition and risk factors of rapidly declining residual renal function in peritoneal dialysis: an observational study. Kidney Blood Press Res. 2012;35(4):233–241. doi: 10.1159/000332887.
    1. Singhal MK, Bhaskaran S, Vidgen E, Bargman JM, Vas SI, Oreopoulos DG. Rate of decline of residual renal function in patients on continuous peritoneal dialysis and factors affecting it. Perit Dial Int. 2000;20(4):429–438.
    1. Hur E, Usta M, Toz H, Asci G, Wabel P, Kahvecioglu S, Kayikcioglu M, Demirci MS, Ozkahya M, Duman S, Ok E. Effect of fluid management guided by bioimpedance spectroscopy on cardiovascular parameters in hemodialysis patients: a randomized controlled trial. Am J Kidney Dis. 2013;61(6):957–965. doi: 10.1053/j.ajkd.2012.12.017.
    1. Wabel P, Chamney P, Moissl U, Jirka T. Importance of whole-body bioimpedance spectroscopy for the management of fluid balance. Blood Purif. 2009;27(1):75–80. doi: 10.1159/000167013.
    1. Moissl UM, Wabel P, Chamney PW, Bosaeus I, Levin NW, Bosy-Westphal A, Korth O, Muller MJ, Ellegard L, Malmros V, Kaitwatcharachai C, Kuhlmann MK, Zhu F, Fuller NJ. Body fluid volume determination via body composition spectroscopy in health and disease. Physiol Meas. 2006;27(9):921–933. doi: 10.1088/0967-3334/27/9/012.
    1. Crepaldi C, Soni S, Chionh CY, Wabel P, Cruz DN, Ronco C. Application of body composition monitoring to peritoneal dialysis patients. Contrib Nephrol. 2009;163:1–6. doi: 10.1159/000223772.
    1. Kim S, Oh J, Chung W, Ahn C, Kim SG, Oh KH. Benefits of biocompatible PD fluid for preservation of residual renal function in incident CAPD patients: a 1-year study. Nephrol Dial Transplant. 2009;24(9):2899–2908. doi: 10.1093/ndt/gfp054.
    1. Maiorca R, Brunori G, Zubani R, Cancarini GC, Manili L, Camerini C, Movilli E, Pola A, d’Avolio G, Gelatti U. Predictive value of dialysis adequacy and nutritional indices for mortality and morbidity in CAPD and HD patients. A longitudinal study. Nephrol Dial Transplant. 1995;10(12):2295–2305.
    1. Bargman JM, Thorpe KE, Churchill DN. Relative contribution of residual renal function and peritoneal clearance to adequacy of dialysis: a reanalysis of the CANUSA study. J Am Soc Nephrol. 2001;12(10):2158–2162.
    1. McCafferty K, Fan S, Davenport A. Extracellular volume expansion, measured by multifrequency bioimpedance, does not help preserve residual renal function in peritoneal dialysis patients. Kidney Int. 2014;85(1):151–157. doi: 10.1038/ki.2013.273.
    1. Davenport A, Sayed RH, Fan S. Is extracellular volume expansion of peritoneal dialysis patients associated with greater urine output? Blood Purif. 2011;32(3):226–231. doi: 10.1159/000329732.
    1. Luo YJ, Lu XH, Woods F, Wang T. Volume control in peritoneal dialysis patients guided by bioimpedance spectroscopy assessment. Blood Purif. 2011;31(4):296–302. doi: 10.1159/000322617.
    1. Luo YJ, Wang T. What is the upper limitation of volume in Chinese peritoneal dialysis patients? Blood Purif. 2011;31(4):289–295. doi: 10.1159/000322615.
    1. Cader RA, Gafor HA, Mohd R, Kong NC, Ibrahim S, Wan Hassan WH, Abdul Rahman WK. Assessment of fluid status in CAPD patients using the body composition monitor. J Clin Nurs. 2013;22(5–6):741–748.
    1. Hur E, Gungor O, Musayev O, Usta M, Toz H, Asci G, Ozkahya M, Duman S, Ok E. Bioimpedance spectroscopy for the detection of hypervolemia in peritoneal dialysis patients. Adv Perit Dial. 2011;27:65–70.
    1. O’Lone EL, Visser A, Finney H, Fan SL. Clinical significance of multi-frequency bioimpedance spectroscopy in peritoneal dialysis patients: independent predictor of patient survival. Nephrol Dial Transplant. 2014;29(7):1430–1437. doi: 10.1093/ndt/gfu049.
    1. Passauer J, Petrov H, Schleser A, Leicht J, Pucalka K. Evaluation of clinical dry weight assessment in haemodialysis patients using bioimpedance spectroscopy: a cross-sectional study. Nephrol Dial Transplant. 2010;25(2):545–551. doi: 10.1093/ndt/gfp517.
    1. Gallar-Ruiz P, Digioia C, Lacalle C, Rodriguez-Villareal I, Laso-Laso N, Hinostroza-Yanahuaya J, Oliet-Pala A, Herrero-Berron JC, Ortega-Marcos O, Ortiz-Libreros M, Mon-Mon C, Cobo-Jaramillo G, Vigil-Medina A. Body composition in patients on haemodialysis: relationship between the type of haemodialysis and inflammatory and nutritional parameters. Nefrologia. 2012;32(4):467–476.
    1. Kim S, Sung J, Jung ES, Park HC, Lee H, Chin HJ, Kim DK, Kim YS, Han JS, Joo KW. Hemodynamic and biochemical benefits of the objective measurement of fluid status in hemodialysis patients. Tohoku J Exp Med. 2012;228(2):125–133. doi: 10.1620/tjem.228.125.
    1. Wabel P, Moissl U, Chamney P, Jirka T, Machek P, Ponce P, Taborsky P, Tetta C, Velasco N, Vlasak J, Zaluska W, Wizemann V. Towards improved cardiovascular management: the necessity of combining blood pressure and fluid overload. Nephrol Dial Transplant. 2008;23(9):2965–2971. doi: 10.1093/ndt/gfn228.
    1. Wizemann V, Wabel P, Chamney P, Zaluska W, Moissl U, Rode C, Malecka-Masalska T, Marcelli D. The mortality risk of overhydration in haemodialysis patients. Nephrol Dial Transplant. 2009;24(5):1574–1579. doi: 10.1093/ndt/gfn707.

Source: PubMed

3
Sottoscrivi